{"id":2205,"date":"2023-11-01T03:32:55","date_gmt":"2023-11-01T03:32:55","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2205"},"modified":"2023-11-01T03:53:47","modified_gmt":"2023-11-01T03:53:47","slug":"4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/da\/vare\/4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRZ\/H(E)-serien pilotstyret proportional retningsbestemt hydraulisk ventil"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRZ\/H(E)-serien pilotstyret proportional retningsbestemt hydraulisk ventil<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2213\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrzhe-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRZ\/H(E) series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilotstyret proportionalstyring<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>Denne funktion sikrer pr\u00e6cis og responsiv styring, hvilket resulterer i forbedret systemydelse, reduceret energiforbrug og \u00f8get produktivitet.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Alsidig retningskontrol<\/li>\n<\/ol>\n<ul>\n<li>Denne ventil tilbyder alsidig kontrol over hydraulikv\u00e6skens retning, hvilket g\u00f8r den velegnet til en bred vifte af anvendelser.<\/li>\n<li>Det muligg\u00f8r problemfri aktivering og deaktivering af hydrauliske komponenter s\u00e5som cylindre, motorer og aktuatorer i forskellige retninger, hvilket forbedrer systemets fleksibilitet og tilpasningsevne.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>H\u00f8j flowkapacitet<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Dens robuste konstruktion sikrer p\u00e5lidelig ydeevne selv under kr\u00e6vende forhold og giver ensartet og effektiv flowkontrol.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Energieffektivitet<\/li>\n<\/ol>\n<ul>\n<li>Ved at indbygge pilotstyret proportionalstyring minimerer denne ventil trykfald og optimerer energiforbruget.<\/li>\n<li>Det hj\u00e6lper med at reducere energiforbruget, hvilket resulterer i omkostningsbesparelser og milj\u00f8m\u00e6ssige fordele.<\/li>\n<\/ul>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>GeneraL<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Installation<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Optional,preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Opbevaringstemperaturomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 til +80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Omgivelsestemperaturomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 til +70<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 til +50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">V\u00e6gt<\/td>\n<td align=\"left\" valign=\"middle\">NS 10<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 16<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.4<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 25<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.4<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 32<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.4<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hydraulisk\u00a0<\/strong>\u00a0\u00a0 (measured with HLPAG.p=100bar : 40 \u2103 \u00b1 5 \u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">St\u00f8rrelse<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Driftstryk<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td align=\"left\" valign=\"middle\">External pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">30 to 100 bar<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Internal pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100 to 350 with &#8220;D3&#8221; only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Hovedventil<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">til 350<\/td>\n<td align=\"left\" valign=\"middle\">til 350<\/td>\n<td align=\"left\" valign=\"middle\">til 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Returtryk<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (Port R) (external pilot oil drain))<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">til 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (internal pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Port Y<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pilot oil volume input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">cm<sup>3<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">1.7<\/td>\n<td align=\"left\" valign=\"middle\">4.6<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">26.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Pilot oil flow in port X and Y with a stepped input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">3.5<\/td>\n<td align=\"left\" valign=\"middle\">5.5<\/td>\n<td align=\"left\" valign=\"middle\">7<\/td>\n<td align=\"left\" valign=\"middle\">15.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of the main valve<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td align=\"left\" valign=\"middle\">to 170<\/td>\n<td align=\"left\" valign=\"middle\">to 460<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0 to 870<\/td>\n<td align=\"left\" valign=\"middle\">to 1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP) to DIN 51524 Further fluids on enquiry<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 \u00a0to +80(preferably +40 to +50)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viskositetsomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">20 \u00a0to 380(preferably 30 to 46)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">Grad af forurening<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 or ISO 4406(c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x \u2265 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 7<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Hovedventil<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 9<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hysterese<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u22646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Elektrisk<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Type of protection of the valve to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65 with cable socket mounted and locked<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Sp\u00e6ndingstype<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value overlap<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. current<\/td>\n<td align=\"left\" valign=\"middle\">EN<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Solenoid coil resisance<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Cold value at 20\u2103<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maks. varm v\u00e6rdi<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Cyklisk varighedsfaktor<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Spoletemperatur<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">til 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Ventilbeskyttelse i henhold til EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Styringselektronik<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">External amplifier for type WRZ<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">VT- VSPA2-L2X\/&#8230;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Kommandov\u00e6rdisignal<\/td>\n<td align=\"left\" valign=\"middle\">-Voltage input &#8220;A1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00b110<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">&#8211;Current input &#8220;F1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">mA<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">4 to 20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve, used to control the size and direction of the liquid flow<br \/>\n\u2022 Threaded connection type proportional solenoid, the coil can be disassembled separately<br \/>\n\u2022 Sub-plate mounting connection structure, connection size conforms to DIN2430 and ISO4401 standards<br \/>\n\u2022 Justering af spolefjedre<br \/>\n\u2022 WRZE type with integrated proportional amplifierr<br \/>\n\u2022 WRZ type external amplifier (order separately)<\/p>\n<h2><strong>Usage Method Of 4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>Systemevaluering<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Evaluer dit hydrauliske system, og identificer de specifikke krav til flow- og retningsstyring.<\/li>\n<li>Determine if the 4WRZ\/H(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Valg af ventil<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRZ\/H(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Overvej faktorer som maksimal flowhastighed, trykklassificering, reaktionstid og driftsforhold.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Installation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>F\u00f8lg producentens installationsvejledning omhyggeligt, og s\u00f8rg for korrekt justering og sikker montering af ventilen.<\/li>\n<li>S\u00f8rg for l\u00e6kagefri forbindelser, og s\u00f8rg for korrekt justering af str\u00f8mningsretningen for at garantere optimal ydeevne.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Tilslutning af styresignal<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Tilslut ventilens styresignalledninger til en passende styreenhed, s\u00e5som en proportionalforst\u00e6rker eller elektronisk styreenhed.<\/li>\n<li>S\u00f8rg for korrekt ledningsf\u00f8ring og kompatibilitet mellem ventilen og styreenheden for at opn\u00e5 pr\u00e6cis og responsiv styring.<\/li>\n<\/ul>\n<h2><strong>How To Bleed Hydraulic Control Valve?<\/strong><\/h2>\n<p>Bleeding a hydraulic control valve is an essential maintenance procedure to remove any trapped air or gas from the system, ensuring optimal performance and efficiency. Here&#8217;s a step-by-step guide on how to bleed a hydraulic control valve:<\/p>\n<ol>\n<li><strong>Forbered systemet:<\/strong>\n<ul>\n<li>Ensure that the hydraulic system is turned off and that the pressure is relieved. This step is crucial for your safety and to prevent any accidental movement or release of high-pressure fluids.<\/li>\n<li>Locate the bleeder valve or bleed screw on the hydraulic control valve. It is typically located on the top or side of the valve body and may have a protective cap or cover.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Positioning and Safety Measures:<\/strong>\n<ul>\n<li>Place a suitable container or absorbent material beneath the bleed valve to catch any fluid that may be expelled during the bleeding process.<\/li>\n<li>Wear appropriate personal protective equipment (PPE), such as safety goggles and gloves, to protect yourself from hydraulic fluid splashes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Opening the Bleed Valve:<\/strong>\n<ul>\n<li>Using an appropriate wrench or tool, carefully loosen the bleed valve or screw counterclockwise. Be cautious not to fully remove it at this stage.<\/li>\n<li>The bleed valve may have an O-ring or sealing washer. Take note of its position and ensure it is in good condition.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Activation:<\/strong>\n<ul>\n<li>Activate the hydraulic system by turning on the power source, such as an engine or hydraulic pump.<\/li>\n<li>Operate the control mechanism associated with the hydraulic control valve, such as a joystick or lever, to allow fluid flow through the valve.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bleeding Process:<\/strong>\n<ul>\n<li>Slowly open the bleed valve by turning it counterclockwise until you start to see hydraulic fluid or air bubbles escaping from the valve.<\/li>\n<li>Allow the fluid to flow for a few seconds or until you observe a steady stream of fluid without any air bubbles. This indicates that the air has been purged from the system.<\/li>\n<li>Be cautious not to open the bleed valve too much, as it may lead to excessive fluid loss or system damage.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Closing the Bleed Valve:<\/strong>\n<ul>\n<li>Once you have successfully bled the system, close the bleed valve by turning it clockwise. Ensure it is tightened securely but avoid over-tightening.<\/li>\n<li>Check for any leaks around the bleed valve or other connections. If you notice any leaks, address them promptly to prevent further issues.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Check:<\/strong>\n<ul>\n<li>Turn off the hydraulic system and inspect the fluid level in the reservoir. Add hydraulic fluid as necessary to maintain the recommended level.<\/li>\n<li>Test the operation of the hydraulic control valve and associated components to ensure proper functionality.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Fabrikkens kapacitet og kapacitet:<\/strong><\/h2>\n<h3>(1) Samling<\/h3>\n<p>Vi har en f\u00f8rsteklasses uafh\u00e6ngig forsknings- og udviklingsplatform til montering. V\u00e6rkstedet for produktion af hydrauliske cylindre har fire halvautomatiske l\u00f8ftecylindermonteringslinjer og en automatisk vippecylindermonteringslinje med en designm\u00e6ssig \u00e5rlig produktionskapacitet p\u00e5 1 million enheder. Det specielle cylinderv\u00e6rksted er udstyret med forskellige specifikationer for et halvautomatisk reng\u00f8ringsmonteringssystem med en designm\u00e6ssig \u00e5rlig produktionskapacitet p\u00e5 200.000 og udstyret med ber\u00f8mt CNC-bearbejdningsudstyr, et bearbejdningscenter, et specialudstyr til h\u00f8jpr\u00e6cisionscylinderbearbejdning, en robotsvejsemaskine, en automatisk reng\u00f8ringsmaskine, en automatisk cylindermonteringsmaskine og en automatisk malingslinje. Eksisterende kritisk udstyr p\u00e5 mere end 300 s\u00e6t (s\u00e6t). Optimal allokering og effektiv udnyttelse af udstyrsressourcer sikrer produkternes n\u00f8jagtighedskrav og opfylder produkternes h\u00f8je kvalitetsbehov.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Maskinbearbejdning<\/h3>\n<p>Bearbejdningsv\u00e6rkstedet er udstyret med et specialfremstillet drejecenter til skr\u00e5 skinner, bearbejdningscenter, h\u00f8jhastigheds-honemaskine, svejserobot og andet relateret udstyr, der kan h\u00e5ndtere bearbejdning af cylinderr\u00f8r med en maksimal indre diameter p\u00e5 400 mm og en maksimal l\u00e6ngde p\u00e5 6 meter.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Svejsning<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Maling og overfladebehandling<\/h3>\n<p>Med sm\u00e5 og mellemstore cylindriske automatiske vandbaserede malingsbel\u00e6gningslinjer, for at opn\u00e5 automatisk robotp\u00e5fyldning og -afl\u00e6sning samt automatisk spr\u00f8jtning, er den designm\u00e6ssige kapacitet p\u00e5 4000 stykker pr. skift;<br \/>\nVi har ogs\u00e5 en halvautomatisk malingsproduktionslinje til store cylindre drevet af en kabelk\u00e6de med en designkapacitet p\u00e5 60 kasser pr. skift.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testning<\/h3>\n<p>Vi har f\u00f8rsteklasses inspektionsfaciliteter og testb\u00e6nke for at sikre, at cylinderens ydeevne opfylder kravene.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Vi er en af \u200b\u200bde bedste producenter af hydrauliske cylindre. Vi kan tilbyde et omfattende udvalg af hydrauliske cylindre. Vi leverer ogs\u00e5 tilsvarende <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">landbrugsgearkasser<\/a>Vi har eksporteret vores produkter til kunder over hele verden og har opn\u00e5et et godt omd\u00f8mme p\u00e5 grund af vores overlegne produktkvalitet og eftersalgsservice. Vi byder kunder i ind- og udland velkommen til at kontakte os for at forhandle forretninger, udveksle information og <a href=\"https:\/\/www.hydraulic-cylinders.net\/da\/contact-us\/\">samarbejde med os<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2214,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/product\/2205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/comments?post=2205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/media\/2214"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/media?parent=2205"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/product_brand?post=2205"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/product_cat?post=2205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/da\/wp-json\/wp\/v2\/product_tag?post=2205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}