{"id":2049,"date":"2023-10-25T06:30:08","date_gmt":"2023-10-25T06:30:08","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2049"},"modified":"2023-10-25T06:30:15","modified_gmt":"2023-10-25T06:30:15","slug":"wmm-series-directional-hydraulic-valve-with-mechanical-manual-operation","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/de\/produkt\/wmm-series-directional-hydraulic-valve-with-mechanical-manual-operation\/","title":{"rendered":"WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2063\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/wmm-series-directional-valve-with-mechanical-manual-operation-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The WMM series directional hydraulic valve with mechanical, manual operation is a versatile and reliable solution designed to control hydraulic systems precisely. This hydraulic valve offers enhanced efficiency and flexibility with its advanced features and robust construction.<\/p>\n<p>The WMM series directional hydraulic valve with mechanical, manual operation is a reliable and versatile solution for hydraulic systems. Its automatic manual operation and precise directional control offer enhanced flexibility and control for various applications. Following the recommended usage methods and adhering to regular maintenance practices, the WMM series hydraulic valve will continue providing efficient and reliable operation. Upgrade your hydraulic system with the WMM series directional valve and experience the benefits of enhanced control and versatility.<\/p>\n<p>WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation Key Characteristics:<\/p>\n<ul>\n<li>Mechanisch, manuelle Bedienung:\n<ul>\n<li>The WMM series hydraulic valve features a mechanical, manual operation, allowing operators to control the valve position manually.<\/li>\n<li>Dies bietet Flexibilit\u00e4t und Kontrolle bei Anwendungen, bei denen eine manuelle Bedienung gew\u00fcnscht oder erforderlich ist.<\/li>\n<\/ul>\n<\/li>\n<li>Richtungssteuerung:\n<ul>\n<li>Dieses Hydraulikventil erm\u00f6glicht eine pr\u00e4zise Steuerung des gerichteten Fl\u00fcssigkeitsstroms innerhalb des Hydrauliksystems.<\/li>\n<li>Es erm\u00f6glicht dem Bediener, den gew\u00fcnschten Str\u00f6mungsweg auszuw\u00e4hlen und so einen effizienten und zuverl\u00e4ssigen Betrieb sicherzustellen.<\/li>\n<\/ul>\n<\/li>\n<li>Langlebige Konstruktion:\n<ul>\n<li>The WMM series hydraulic valve is constructed with high-quality materials, ensuring durability and longevity.<\/li>\n<li>Dank seiner robusten Bauweise h\u00e4lt es auch anspruchsvollen Betriebsbedingungen stand und bietet zuverl\u00e4ssige Leistung.<\/li>\n<\/ul>\n<\/li>\n<li>Kompakte Gr\u00f6\u00dfe:\n<ul>\n<li>The valve&#8217;s compact size allows easy integration into hydraulic systems with limited space.<\/li>\n<li>It is ideal for applications where space is a constraint without compromising performance.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation Parameter:<\/strong><\/h2>\n<p><strong>NG6<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" style=\"height: 301px;\">\n<tbody>\n<tr class=\"firstRow\" style=\"height: 23px;\">\n<td style=\"height: 46px; width: 298.6px;\" colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeitstemperaturbereich<\/td>\n<td style=\"height: 46px; width: 44.6125px;\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0\u2103<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">-30 bis +80 (NBR-Dichtungen)<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">-20 bis +80 (FKM-Dichtungen)<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"height: 70px; width: 226.775px;\" rowspan=\"2\" align=\"left\" valign=\"middle\">Anschluss Max. Betriebsdruck<\/td>\n<td style=\"height: 47px; width: 66.625px;\" align=\"left\" valign=\"middle\">Port ABP<\/td>\n<td style=\"height: 47px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0Bar<\/td>\n<td style=\"height: 47px; width: 569.987px;\" align=\"left\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 66.625px;\" align=\"left\" valign=\"middle\">Anschluss T<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0Bar<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">160<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 298.6px;\" colspan=\"2\" align=\"left\" valign=\"middle\">Max. Durchfluss<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0L\/min<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">60<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 46px; width: 226.775px;\" rowspan=\"2\" align=\"left\" valign=\"middle\">Flowrea (Schaltneutralstellung)<\/td>\n<td style=\"height: 23px; width: 66.625px;\" align=\"left\" valign=\"middle\">Q-Typ<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup><\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">F\u00fcr Symbol Q, 6% des Nennquerschnitts<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 66.625px;\" align=\"left\" valign=\"middle\">W-Typ<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup><\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">F\u00fcr Symbol W, 3% des Nennquerschnitts<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 348.413px;\" colspan=\"3\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeit<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">Mineral\u00f6l; Phosphatester<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 298.6px;\" colspan=\"2\" align=\"left\" valign=\"middle\">Viskosit\u00e4tsbereich<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">2,8 bis 500<\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"height: 47px; width: 348.413px;\" colspan=\"3\" align=\"left\" valign=\"middle\">Verschmutzungsgrad<\/td>\n<td style=\"height: 47px; width: 569.987px;\" align=\"left\" valign=\"middle\">Maximal zul\u00e4ssiger Verschmutzungsgrad der Fl\u00fcssigkeit: Klasse 9. NAS 1638 oder 20\/18\/15, ISO4406<\/td>\n<\/tr>\n<tr style=\"height: 23px;\">\n<td style=\"height: 23px; width: 298.6px;\" colspan=\"2\" align=\"left\" valign=\"middle\">Gewicht<\/td>\n<td style=\"height: 23px; width: 44.6125px;\" align=\"left\" valign=\"middle\">\u00a0kg<\/td>\n<td style=\"height: 23px; width: 569.987px;\" align=\"left\" valign=\"middle\">1.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeitstemperaturbereich<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0\u2103<\/td>\n<td align=\"left\" valign=\"middle\">-30 bis +80 (NBR-Dichtungen)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">-20 bis +80 (FKM-Dichtungen)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Anschluss Max. Betriebsdruck<\/td>\n<td align=\"left\" valign=\"middle\">Port ABP<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0Bar<\/td>\n<td align=\"left\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Anschluss T<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0Bar<\/td>\n<td align=\"left\" valign=\"middle\">160<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. Durchfluss<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0L\/min<\/td>\n<td align=\"left\" valign=\"middle\">120<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Durchflussquerschnitt (Schaltneutralstellung)<\/td>\n<td align=\"left\" valign=\"middle\">V-Typ<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">11(A\/B \u2192 T);10.3(P \u2192 A\/B)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">W-Typ<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">2,5 (A\/B \u2192 T)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">Q-Typ<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">mm<sup>2<\/sup><\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">5,5 (A\/B \u2192 T)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeit<\/td>\n<td align=\"left\" valign=\"middle\">Mineral\u00f6l; Phosphatester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Viskosit\u00e4tsbereich<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td align=\"left\" valign=\"middle\">2,8 bis 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Verschmutzungsgrad<\/td>\n<td align=\"left\" valign=\"middle\">Maximal zul\u00e4ssiger Verschmutzungsgrad der Fl\u00fcssigkeit: Klasse 9. NAS 1638 oder 20\/18\/15, ISO4406<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Gewicht<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0kg<\/td>\n<td align=\"left\" valign=\"middle\">4.4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16-32<\/strong><\/p>\n<table data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td align=\"left\" valign=\"middle\">NS<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Gewicht<\/td>\n<td align=\"left\" valign=\"middle\">about 8<\/td>\n<td align=\"left\" valign=\"middle\">about 12.2<\/td>\n<td align=\"left\" valign=\"middle\">about 49<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Actuation force\u00a0 \u00a0with detent \u00a0N<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">about 75<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">about 105<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">about 170<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 with spring return N<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Actuation angle about the neutral position<\/td>\n<td align=\"left\" valign=\"middle\">2*26\u00b0<\/td>\n<td align=\"left\" valign=\"middle\">2*32<sup>\u00b0<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">2*30<sup>\u00b0<\/sup><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\u00a0Port A,B,P\u00a0bar<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port T\u00a0bar<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeit<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Mineral\u00f6l geeignet f\u00fcr NBR- und FKM-Dichtungen<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Phosphate ester &#8211; for FKM seal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fl\u00fcssigkeitstemperaturbereich<\/td>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-30 to +80\uff08NBR seal\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 bis +80 (FKM-Dichtung)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">Viscosity range\u00a0\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0380<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">Verschmutzungsgrad<\/td>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Maximal zul\u00e4ssiger Verschmutzungsgrad der Fl\u00fcssigkeit: Klasse 9. NAS 1638 oder 20\/18\/15, ISO4406<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation Advantages:<\/strong><\/h2>\n<p>\u2022 Direktwirkendes Wegeschieberventil Direktwirkendes Wegeschieberventil<br \/>\n\u2022 Unterplattenmontage<br \/>\n\u2022 Handle control<br \/>\n\u2022 Einbauseite nach DIN 24340 A, ISO 4401<\/p>\n<h2><strong>Usage Method Of WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Systemintegration:<\/strong>\n<ul>\n<li>Identify the appropriate location for the WMM series hydraulic valve within the hydraulic system, considering the desired flow direction and control requirements.<\/li>\n<li>Stellen Sie die Kompatibilit\u00e4t mit den Druck- und Durchflussspezifikationen des Systems sicher.<\/li>\n<li>Montieren Sie das Ventil sicher mit entsprechenden Halterungen oder Montagezubeh\u00f6r.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Fluidanschl\u00fcsse:<\/strong>\n<ul>\n<li>W\u00e4hlen Sie kompatible Hydraulikarmaturen und -schl\u00e4uche f\u00fcr sichere und leckagefreie Verbindungen.<\/li>\n<li>Befolgen Sie w\u00e4hrend des Installationsvorgangs die Anweisungen des Herstellers hinsichtlich der richtigen Drehmomentwerte.<\/li>\n<li>Verwenden Sie geeignete Gewindedichtmittel oder Klebeband, um eine zuverl\u00e4ssige Abdichtung zu gew\u00e4hrleisten.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Manuelle Bedienung:<\/strong>\n<ul>\n<li>Familiarize yourself with the manual operation mechanism of the valve, including the lever or knob used to control the hydraulic valve position.<\/li>\n<li>Stellen Sie sicher, dass der Bediener die korrekte Vorgehensweise zum manuellen Einstellen der Ventilposition versteht.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Systemkalibrierung:<\/strong>\n<ul>\n<li>Calibrate the hydraulic valve position and movement according to the desired flow direction and control requirements.<\/li>\n<li>Stellen Sie das Ventil manuell ein, um den gew\u00fcnschten Durchflussweg zu erreichen und die ordnungsgem\u00e4\u00dfe Funktionalit\u00e4t sicherzustellen.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How To Adjust Valves On A Hydraulic Roller Cam?<\/strong><\/h2>\n<p>Adjusting valves on a hydraulic roller cam requires careful attention to detail and following the proper procedure. Here&#8217;s a step-by-step guide to help you adjust the valves correctly:<\/p>\n<ol>\n<li><strong>Bereiten Sie den Motor vor:<\/strong>\n<ul>\n<li>Ensure the engine is turned off and cool to the touch before starting the adjustment process.<\/li>\n<li>Locate the valve covers and remove them to access the valve train components.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Ermitteln Sie die korrekte Reihenfolge der Ventileinstellung:<\/strong>\n<ul>\n<li>Konsultieren Sie die Spezifikationen oder das Servicehandbuch des Motorenherstellers, um die korrekte Ventilspiel-Einstellreihenfolge f\u00fcr Ihren spezifischen Motor zu ermitteln.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Ermitteln Sie die Position des oberen Totpunkts (OT):<\/strong>\n<ul>\n<li>Rotate the engine&#8217;s crankshaft in the normal direction of rotation until the number one piston reaches the top dead center position on its compression stroke.<\/li>\n<li>Use a timing mark on the harmonic balancer or flywheel and a timing pointer to identify the TDC position accurately.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Adjusting Valve Lash:<\/strong>\n<ul>\n<li>Begin with the first cylinder in the valve adjustment sequence.<\/li>\n<li>Loosen the lock nut on the rocker arm stud using an appropriate wrench or socket.<\/li>\n<li>Use a feeler gauge of the recommended thickness specified by the engine manufacturer to check the valve lash (clearance) between the rocker arm and the valve stem.<\/li>\n<li>Slide the feeler gauge between the rocker arm and the valve stem. You should feel slight resistance but still be able to move the gauge back and forth.<\/li>\n<li>Adjust the valve lash by either tightening or loosening the rocker arm stud until the proper clearance is achieved. Turning the stud clockwise decreases the clearance, while counterclockwise increases it.<\/li>\n<li>Once you&#8217;ve set the correct valve lash, hold the rocker arm stud in place and tighten the lock nut securely.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Wiederholen Sie den Vorgang:<\/strong>\n<ul>\n<li>Move to the next cylinder in the valve adjustment sequence and repeat steps 4 and 5 until all the valves have been adjusted.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Ventildeckel wieder einbauen:<\/strong>\n<ul>\n<li>Sobald Sie die Ventileinstellung an allen Zylindern abgeschlossen haben, montieren Sie die Ventildeckel wieder und stellen Sie sicher, dass sie ordnungsgem\u00e4\u00df abgedichtet sind, um \u00d6llecks zu vermeiden.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Doppelt pr\u00fcfen:<\/strong>\n<ul>\n<li>After adjusting the valves, it&#8217;s a good practice to go through the entire valve adjustment sequence once more to confirm that all clearances are within the specified range.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>F\u00e4higkeit und Kapazit\u00e4t der Fabrik:<\/strong><\/h2>\n<h3>(1) Montage<\/h3>\n<p>Wir verf\u00fcgen \u00fcber eine erstklassige, unabh\u00e4ngige Forschungs- und Entwicklungsmontageplattform. Die Hydraulikzylinder-Produktionswerkstatt verf\u00fcgt \u00fcber vier halbautomatische Montagelinien f\u00fcr Hubzylinder und eine automatische Montagelinie f\u00fcr Kippzylinder mit einer geplanten j\u00e4hrlichen Produktionskapazit\u00e4t von 1 Million St\u00fcck. Die Spezialzylinderwerkstatt ist mit verschiedenen Spezifikationen eines halbautomatischen Reinigungsmontagesystems mit einer geplanten j\u00e4hrlichen Produktionskapazit\u00e4t von 200.000 ausgestattet und mit renommierten CNC-Bearbeitungsger\u00e4ten, einem Bearbeitungszentrum, einer hochpr\u00e4zisen Spezialausr\u00fcstung f\u00fcr die Zylinderverarbeitung, einer Roboterschwei\u00dfmaschine, einer automatischen Reinigungsmaschine, einer automatischen Zylindermontagemaschine und einer automatischen Lackierproduktionslinie ausgestattet. Es sind mehr als 300 Sets (S\u00e4tze) an kritischer Ausr\u00fcstung vorhanden. Die optimale Zuweisung und effiziente Nutzung der Ausr\u00fcstungsressourcen gew\u00e4hrleistet die Genauigkeitsanforderungen der Produkte und erf\u00fcllt die hohen Qualit\u00e4tsanforderungen der Produkte.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Bearbeitungen<\/h3>\n<p>Die Bearbeitungswerkstatt ist mit einem ma\u00dfgeschneiderten Schr\u00e4gschienen-Drehzentrum, einem Bearbeitungszentrum, einer Hochgeschwindigkeits-Honmaschine, einem Schwei\u00dfroboter und anderen zugeh\u00f6rigen Ger\u00e4ten ausgestattet, die die Bearbeitung von Zylinderrohren mit einem maximalen Innendurchmesser von 400 mm und einer maximalen L\u00e4nge von 6 Metern erm\u00f6glichen.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Schwei\u00dfen<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Malerei und Beschichtung<\/h3>\n<p>Mit kleinen und mittleren Zylinder automatische Lackieranlagen auf Wasserbasis, zu erreichen automatische Roboter Be-und Entladen und automatische Spritzen, die Design-Kapazit\u00e4t von 4000 St\u00fcck pro Schicht;<br \/>\nWir verf\u00fcgen auch \u00fcber eine halbautomatische Lackieranlage f\u00fcr gro\u00dfe Zylinder, die von einer Energiekette angetrieben wird und eine Kapazit\u00e4t von 60 Kisten pro Schicht hat.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Pr\u00fcfung<\/h3>\n<p>Wir verf\u00fcgen \u00fcber erstklassige Pr\u00fcfeinrichtungen und Pr\u00fcfst\u00e4nde, um sicherzustellen, dass die Leistung des Zylinders den Anforderungen entspricht.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Wir sind einer der besten Hydraulikzylinderhersteller. Wir k\u00f6nnen umfassende Hydraulikzylinder anbieten. Wir bieten auch entsprechende <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">landwirtschaftliche Getriebe<\/a>. Wir haben unsere Produkte an Kunden weltweit exportiert und uns aufgrund unserer hervorragenden Produktqualit\u00e4t und unseres Kundendienstes einen guten Ruf erworben. Wir begr\u00fc\u00dfen Kunden im In- und Ausland, die uns kontaktieren, um Gesch\u00e4fte zu verhandeln, Informationen auszutauschen und <a href=\"https:\/\/www.hydraulic-cylinders.net\/de\/contact-us\/\">mit uns zusammenarbeiten<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WMM Series Directional Hydraulic Valve With Mechanical, Manual Operation The WMM series directional hydraulic valve with mechanical, manual operation is a versatile and reliable solution designed to control hydraulic systems precisely. This hydraulic valve offers enhanced efficiency and flexibility with its advanced features and robust construction. The WMM series directional hydraulic valve with mechanical, manual [&hellip;]<\/p>","protected":false},"featured_media":2064,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2049","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product\/2049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/comments?post=2049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/media\/2064"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/media?parent=2049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_brand?post=2049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_cat?post=2049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_tag?post=2049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}