{"id":2205,"date":"2023-11-01T03:32:55","date_gmt":"2023-11-01T03:32:55","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2205"},"modified":"2023-11-01T03:53:47","modified_gmt":"2023-11-01T03:53:47","slug":"4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/de\/produkt\/4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2213\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrzhe-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRZ\/H(E) series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilot-Operated Proportional Control<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>Diese Funktion gew\u00e4hrleistet eine pr\u00e4zise und reaktionsschnelle Steuerung, was zu einer verbesserten Systemleistung, einem geringeren Energieverbrauch und einer h\u00f6heren Produktivit\u00e4t f\u00fchrt.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Versatile Directional Control<\/li>\n<\/ol>\n<ul>\n<li>Dieses Ventil bietet eine vielseitige Steuerung der Hydraulikfl\u00fcssigkeitsrichtung und ist daher f\u00fcr eine breite Palette von Anwendungen geeignet.<\/li>\n<li>Es erm\u00f6glicht die nahtlose Aktivierung und Deaktivierung hydraulischer Komponenten wie Zylinder, Motoren und Aktuatoren in verschiedene Richtungen und verbessert so die Flexibilit\u00e4t und Anpassungsf\u00e4higkeit des Systems.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>High Flow Capacity<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Seine robuste Konstruktion gew\u00e4hrleistet eine zuverl\u00e4ssige Leistung auch unter anspruchsvollen Bedingungen und sorgt f\u00fcr eine konsistente und effiziente Durchflusskontrolle.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Energieeffizienz<\/li>\n<\/ol>\n<ul>\n<li>By incorporating pilot-operated proportional control, this valve minimizes pressure drops and optimizes energy usage.<\/li>\n<li>Es tr\u00e4gt zur Reduzierung des Energieverbrauchs bei, was zu Kosteneinsparungen und \u00f6kologischen Vorteilen f\u00fchrt.<\/li>\n<\/ul>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>GeneraL<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Installation<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Optional,preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Storage temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 bis +80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Umgebungstemperaturbereich<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 bis +70<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 to +50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Gewicht<\/td>\n<td align=\"left\" valign=\"middle\">NS 10<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 16<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.4<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 25<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.4<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 32<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.4<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hydraulisch\u00a0<\/strong>\u00a0\u00a0 (measured with HLPAG.p=100bar : 40 \u2103 \u00b1 5 \u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Gr\u00f6\u00dfe<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Betriebsdruck<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td align=\"left\" valign=\"middle\">External pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">30 to 100 bar<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Internal pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100 to 350 with &#8220;D3&#8221; only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Main valve<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">bis 350<\/td>\n<td align=\"left\" valign=\"middle\">bis 350<\/td>\n<td align=\"left\" valign=\"middle\">bis 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Return pressure<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (Port R) (external pilot oil drain))<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (internal pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Anschluss Y<\/td>\n<td align=\"left\" valign=\"middle\">Bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pilot oil volume input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">cm<sup>3<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">1.7<\/td>\n<td align=\"left\" valign=\"middle\">4.6<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">26.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Pilot oil flow in port X and Y with a stepped input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">3.5<\/td>\n<td align=\"left\" valign=\"middle\">5.5<\/td>\n<td align=\"left\" valign=\"middle\">7<\/td>\n<td align=\"left\" valign=\"middle\">15.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of the main valve<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\">to 170<\/td>\n<td align=\"left\" valign=\"middle\">to 460<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0 to 870<\/td>\n<td align=\"left\" valign=\"middle\">to 1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulikfl\u00fcssigkeit<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP) to DIN 51524 Further fluids on enquiry<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 \u00a0to +80(preferably +40 to +50)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viskosit\u00e4tsbereich<\/td>\n<td align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">20 \u00a0to 380(preferably 30 to 46)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">Verschmutzungsgrad<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 or ISO 4406(c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x \u2265 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 7<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Main valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 9<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hysterese<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u22646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electrical<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Type of protection of the valve to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65 with cable socket mounted and locked<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Spannungstyp<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Gleichstrom<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value overlap<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. current<\/td>\n<td align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Solenoid coil resisance<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Cold value at 20\u2103<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maximaler Warmwert<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Faktor der Zyklusdauer<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Spulentemperatur<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Ventilschutz nach EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Control electronics<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">External amplifier for type WRZ<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">VT- VSPA2-L2X\/&#8230;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Befehlswertsignal<\/td>\n<td align=\"left\" valign=\"middle\">-Voltage input &#8220;A1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00b110<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">&#8211;Current input &#8220;F1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">mA<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">4 to 20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve, used to control the size and direction of the liquid flow<br \/>\n\u2022 Threaded connection type proportional solenoid, the coil can be disassembled separately<br \/>\n\u2022 Sub-plate mounting connection structure, connection size conforms to DIN2430 and ISO4401 standards<br \/>\n\u2022 Spool spring alignment alignment<br \/>\n\u2022 WRZE type with integrated proportional amplifierr<br \/>\n\u2022 WRZ type external amplifier (order separately)<\/p>\n<h2><strong>Usage Method Of 4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>System Evaluation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Bewerten Sie Ihr Hydrauliksystem und ermitteln Sie die spezifischen Anforderungen an die Durchfluss- und Richtungssteuerung.<\/li>\n<li>Determine if the 4WRZ\/H(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Valve Selection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRZ\/H(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Ber\u00fccksichtigen Sie Faktoren wie maximale Durchflussrate, Druckstufe, Reaktionszeit und Betriebsbedingungen.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Installation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Befolgen Sie die Installationsanweisungen des Herstellers sorgf\u00e4ltig und achten Sie auf die richtige Ausrichtung und sichere Montage des Ventils.<\/li>\n<li>Make leak-free connections and ensure the correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Control Signal Connection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Schlie\u00dfen Sie die Steuersignalleitungen des Ventils an ein geeignetes Steuerger\u00e4t an, beispielsweise einen Proportionalverst\u00e4rker oder eine elektronische Steuereinheit.<\/li>\n<li>Sorgen Sie f\u00fcr eine korrekte Verkabelung und Kompatibilit\u00e4t zwischen Ventil und Steuerger\u00e4t, um eine pr\u00e4zise und reaktionsschnelle Steuerung zu gew\u00e4hrleisten.<\/li>\n<\/ul>\n<h2><strong>How To Bleed Hydraulic Control Valve?<\/strong><\/h2>\n<p>Bleeding a hydraulic control valve is an essential maintenance procedure to remove any trapped air or gas from the system, ensuring optimal performance and efficiency. Here&#8217;s a step-by-step guide on how to bleed a hydraulic control valve:<\/p>\n<ol>\n<li><strong>Bereiten Sie das System vor:<\/strong>\n<ul>\n<li>Ensure that the hydraulic system is turned off and that the pressure is relieved. This step is crucial for your safety and to prevent any accidental movement or release of high-pressure fluids.<\/li>\n<li>Locate the bleeder valve or bleed screw on the hydraulic control valve. It is typically located on the top or side of the valve body and may have a protective cap or cover.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Positioning and Safety Measures:<\/strong>\n<ul>\n<li>Place a suitable container or absorbent material beneath the bleed valve to catch any fluid that may be expelled during the bleeding process.<\/li>\n<li>Wear appropriate personal protective equipment (PPE), such as safety goggles and gloves, to protect yourself from hydraulic fluid splashes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Opening the Bleed Valve:<\/strong>\n<ul>\n<li>Using an appropriate wrench or tool, carefully loosen the bleed valve or screw counterclockwise. Be cautious not to fully remove it at this stage.<\/li>\n<li>The bleed valve may have an O-ring or sealing washer. Take note of its position and ensure it is in good condition.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Activation:<\/strong>\n<ul>\n<li>Activate the hydraulic system by turning on the power source, such as an engine or hydraulic pump.<\/li>\n<li>Operate the control mechanism associated with the hydraulic control valve, such as a joystick or lever, to allow fluid flow through the valve.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bleeding Process:<\/strong>\n<ul>\n<li>Slowly open the bleed valve by turning it counterclockwise until you start to see hydraulic fluid or air bubbles escaping from the valve.<\/li>\n<li>Allow the fluid to flow for a few seconds or until you observe a steady stream of fluid without any air bubbles. This indicates that the air has been purged from the system.<\/li>\n<li>Be cautious not to open the bleed valve too much, as it may lead to excessive fluid loss or system damage.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Closing the Bleed Valve:<\/strong>\n<ul>\n<li>Once you have successfully bled the system, close the bleed valve by turning it clockwise. Ensure it is tightened securely but avoid over-tightening.<\/li>\n<li>Check for any leaks around the bleed valve or other connections. If you notice any leaks, address them promptly to prevent further issues.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Systempr\u00fcfung:<\/strong>\n<ul>\n<li>Turn off the hydraulic system and inspect the fluid level in the reservoir. Add hydraulic fluid as necessary to maintain the recommended level.<\/li>\n<li>Test the operation of the hydraulic control valve and associated components to ensure proper functionality.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>F\u00e4higkeit und Kapazit\u00e4t der Fabrik:<\/strong><\/h2>\n<h3>(1) Montage<\/h3>\n<p>Wir verf\u00fcgen \u00fcber eine erstklassige, unabh\u00e4ngige Forschungs- und Entwicklungsmontageplattform. Die Hydraulikzylinder-Produktionswerkstatt verf\u00fcgt \u00fcber vier halbautomatische Montagelinien f\u00fcr Hubzylinder und eine automatische Montagelinie f\u00fcr Kippzylinder mit einer geplanten j\u00e4hrlichen Produktionskapazit\u00e4t von 1 Million St\u00fcck. Die Spezialzylinderwerkstatt ist mit verschiedenen Spezifikationen eines halbautomatischen Reinigungsmontagesystems mit einer geplanten j\u00e4hrlichen Produktionskapazit\u00e4t von 200.000 ausgestattet und mit renommierten CNC-Bearbeitungsger\u00e4ten, einem Bearbeitungszentrum, einer hochpr\u00e4zisen Spezialausr\u00fcstung f\u00fcr die Zylinderverarbeitung, einer Roboterschwei\u00dfmaschine, einer automatischen Reinigungsmaschine, einer automatischen Zylindermontagemaschine und einer automatischen Lackierproduktionslinie ausgestattet. Es sind mehr als 300 Sets (S\u00e4tze) an kritischer Ausr\u00fcstung vorhanden. Die optimale Zuweisung und effiziente Nutzung der Ausr\u00fcstungsressourcen gew\u00e4hrleistet die Genauigkeitsanforderungen der Produkte und erf\u00fcllt die hohen Qualit\u00e4tsanforderungen der Produkte.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Bearbeitungen<\/h3>\n<p>Die Bearbeitungswerkstatt ist mit einem ma\u00dfgeschneiderten Schr\u00e4gschienen-Drehzentrum, einem Bearbeitungszentrum, einer Hochgeschwindigkeits-Honmaschine, einem Schwei\u00dfroboter und anderen zugeh\u00f6rigen Ger\u00e4ten ausgestattet, die die Bearbeitung von Zylinderrohren mit einem maximalen Innendurchmesser von 400 mm und einer maximalen L\u00e4nge von 6 Metern erm\u00f6glichen.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Schwei\u00dfen<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Malerei und Beschichtung<\/h3>\n<p>Mit kleinen und mittleren Zylinder automatische Lackieranlagen auf Wasserbasis, zu erreichen automatische Roboter Be-und Entladen und automatische Spritzen, die Design-Kapazit\u00e4t von 4000 St\u00fcck pro Schicht;<br \/>\nWir verf\u00fcgen auch \u00fcber eine halbautomatische Lackieranlage f\u00fcr gro\u00dfe Zylinder, die von einer Energiekette angetrieben wird und eine Kapazit\u00e4t von 60 Kisten pro Schicht hat.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Pr\u00fcfung<\/h3>\n<p>Wir verf\u00fcgen \u00fcber erstklassige Pr\u00fcfeinrichtungen und Pr\u00fcfst\u00e4nde, um sicherzustellen, dass die Leistung des Zylinders den Anforderungen entspricht.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Wir sind einer der besten Hydraulikzylinderhersteller. Wir k\u00f6nnen umfassende Hydraulikzylinder anbieten. Wir bieten auch entsprechende <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">landwirtschaftliche Getriebe<\/a>. Wir haben unsere Produkte an Kunden weltweit exportiert und uns aufgrund unserer hervorragenden Produktqualit\u00e4t und unseres Kundendienstes einen guten Ruf erworben. Wir begr\u00fc\u00dfen Kunden im In- und Ausland, die uns kontaktieren, um Gesch\u00e4fte zu verhandeln, Informationen auszutauschen und <a href=\"https:\/\/www.hydraulic-cylinders.net\/de\/contact-us\/\">mit uns zusammenarbeiten<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2214,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product\/2205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/comments?post=2205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/media\/2214"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/media?parent=2205"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_brand?post=2205"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_cat?post=2205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/de\/wp-json\/wp\/v2\/product_tag?post=2205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}