30SD10-21 Solenoid Directional Valve

Üheks hüdrosilindrite tootjaks, tarnijaks ja mehaaniliste toodete eksportijaks pakume hüdrosilindreid ja paljusid teisi tooteid.

Palun võtke meiega ühendust üksikasjade saamiseks.

Post:sales@hydraulic-cylinders.net

Tootja tarnija eksportija hüdrosilindrid.

30SD10-21 Solenoid Directional Valve

The 30SD10-21 solenoid directional valve is a high-performance component that optimizes fluid control in various industrial applications. With its advanced features, precise operation, and reliable performance, this solenoid valve offers exceptional functionality and efficiency, making it a valuable asset for fluid control systems. From manufacturing to automation, the 30SD10-21 solenoid directional valve delivers precise and reliable fluid control, empowering industries to enhance productivity and streamline operations.

The 30SD10-21 solenoid directional valve is a versatile and reliable component that enhances fluid control efficiency in industrial applications. With its robust construction, precise fluid control, versatility, and reliable performance, this solenoid valve offers exceptional functionality, ensuring optimal operations and increased productivity. By incorporating the 30SD10-21 solenoid directional valve into fluid control systems, industries can achieve enhanced efficiency, accuracy, and system performance. Invest in this advanced solenoid valve to streamline your fluid control processes, improve productivity, and gain a competitive edge in your industry.

30SD10-21 Solenoid Directional Valve Characteristics:

  • Robust Construction: The 30SD10-21 solenoid directional valve is built robustly, ensuring durability and longevity even in demanding environments. Its sturdy construction allows it to withstand high pressures, temperature variations, and harsh conditions, providing consistent and reliable performance.
  • Precise Fluid Control: This solenoid valve offers precise control over fluid flow, allowing for accurate regulation and efficient management of liquids or gases. With its responsive solenoid mechanism, the valve enables quick and reliable switching between different flow paths, ensuring precise control and minimizing disruptions.
  • Versatile Functionality: The 30SD10-21 solenoid directional valve offers versatile functionality, making it suitable for various applications. Whether directional control, on/off switch, or pressure regulation, this valve can be tailored to meet specific system requirements, providing flexibility and adaptability in fluid control systems.
  • Reliable Performance: This solenoid valve is designed for reliable performance, ensuring consistent and efficient fluid control operations. Its high-quality components and precision engineering contribute to its reliability, allowing for smooth and trouble-free operation even in critical applications.

30SD10-21 Solenoid Directional Valve Parameter:

Rated pressure241 bar (3500 psi)
Peak flow56.8 L/min (15 gpm) ; See performance chart
FluidMineral-based or synthetics with lubricating properties
Fluid temperature range ℃-54 to 107 ℃ (Polyurethane seals)
-40 to 100 ℃ (Buna N seals)
-26 to 204 ℃ (Fluorocarbon seals)
Viscosity range7.4 to 420 mm2/s
Degree of contaminationThe minimum pollution level is ISO4406 level 18/16/13, and level 15/13/11 is recommended to prolong the service life
Internal Leakage≤ 0.15 mL/min (3 drops /min) @241 bar
CavityVC10-2
Coil Duty RatingContinuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20℃E-coil1.7A at 12VDC; 0.85A at 24VDC
D-coil1.67A at 12VDC; 0.83A at 24VDC
Minimum pull-in voltage85% of nominal at 241 bar

30SD10-21 Solenoid Directional Valve Advantages:

• Continuous-duty rated coil
• Efficient wet-armature construction
• Cartridges are voltage interchangeable
• Optional waterproof E-Coils rated up to IP69K
• Industry common cavity
• Hardened parts for long life and low leakage

Usage Method Of 30SD10-21 Solenoid Directional Valve:

Installation:

  • Follow the manufacturer’s instructions for properly installing the 30SD10-21 Solenoid Directional Valve.
  • Ensure accurate alignment and connection to the fluid control system, using appropriate fittings and seals to maintain a leak-free operation.

Electrical Connections:

  • Connect the solenoid valve to the power supply, adhering to the specified voltage and electrical requirements.
  • Ensure proper wiring and insulation to ensure safe and reliable electrical operation.

Fluid Flow Direction:

  • Determine the desired fluid flow direction based on the application requirements.
  • The 30SD10-21 solenoid directional valve provides various ports and positions for inlet, outlet, and exhaust. Refer to the product documentation for correct port connections.

Control Signal:

  • Connect the control signal, whether electrical or pneumatic, to the solenoid valve to activate its switching mechanism.
  • Ensure that the control signal is compatible with the valve’s specifications and operating parameters.

How To Hook Up A Hydraulic Flow Control Valve?

To hook up a hydraulic flow control valve, follow these steps:

  1. Identify Valve Type: Determine the specific type of flow control valve you are working with. Common types include needle valves, adjustable flow control valves, or pressure-compensated flow control valves. Ensure that the valve is suitable for your application and compatible with your hydraulic system.
  2. Gather Required Tools and Materials: Collect the necessary tools and materials, including appropriate hydraulic fittings, adapters, hoses, and wrenches.
  3. Prepare the Hydraulic System: Shut down the hydraulic system and relieve any pressure in the system by activating the relief valve or retracting any hydraulic cylinders. This step is crucial for safety.
  4. Identify Flow Direction: Identify the flow direction in your hydraulic system. Typically, the flow direction is indicated by arrows on the hydraulic components. Ensure that you understand the correct flow direction before proceeding.
  5. Locate Installation Point: Determine the optimal location to install the flow control valve in your hydraulic system. Consider factors such as accessibility, proximity to the actuator or hydraulic component, and ease of adjustment.
  6. Mount the Valve: Securely mount the flow control valve in the chosen location using appropriate brackets or clamps. Ensure the valve is positioned correctly, aligning the inlet and outlet ports with the flow direction.
  7. Connect the Inlet and Outlet Ports: Attach hydraulic hoses or tubing to the inlet and outlet ports of the flow control valve. Use suitable hydraulic fittings and adapters to create a leak-free connection. Tighten the connections using wrenches to ensure a secure fit, but avoid over-tightening.
  8. Adjust the Flow Control: Depending on the type of flow control valve, it may have adjustable features such as a needle valve or a flow control knob. Adjust the valve according to your desired flow rate or speed. Refer to the manufacturer’s instructions for specific adjustment procedures.
  9. Test the System: Once the flow control valve is installed and adjusted, slowly restore hydraulic system pressure. Test the system to ensure that the flow control valve is functioning correctly. Monitor the flow rate or speed of the hydraulic actuator to verify that it is within the desired range.
  10. Fine-tune and Monitor: Adjust the flow control valve to achieve the desired flow rate or speed. Regularly monitor the hydraulic system for leaks, pressure inconsistencies, or unusual behavior.

Tehase võimekus ja suutlikkus:

(1) Kokkupanek

Meil on esmaklassiline sõltumatu teadus- ja arendustegevuse montaažiplatvorm. Hüdrosilindrite tootmistöökojas on neli poolautomaatset tõstesilindrite koosteliini ja üks automaatne kallutussilindrite koosteliin, mille kavandatud aastane tootmisvõimsus on 1 miljon tükki. Spetsiaalsete silindrite töökoda on varustatud erinevate spetsifikatsioonidega poolautomaatse puhastusmontaažisüsteemiga, mille kavandatud aastane tootmisvõimsus on 200 000 ja mis on varustatud kuulsate CNC-töötlemisseadmete, mehaanilise töötlemise keskuse, suure täpsusega silindrite töötlemise eriseadmete, robotkeevitusmasina, automaatse puhastusmasina, automaatse silindri kokkupanemise masina ja automaatse värvimise tootmisliiniga. Olemasolevad kriitilised seadmed rohkem kui 300 komplekti (komplekti). Seadmete ressursside optimaalne jaotamine ja tõhus kasutamine tagavad toodete täpsusnõuded ja vastavad toodete kvaliteedinõuetele.

(2) Töötlemine

Töödeldav töökoda on varustatud kohandatud kallutatud rööpse treipingi keskuse, mehaanilise keskuse, kiire lihvimismasina, keevitusroboti ja muude seotud seadmetega, mis suudavad töödelda silindritorusid, mille maksimaalne siseläbimõõt on 400 mm ja maksimaalne pikkus on 6 meetrit.

(3) Keevitamine

(4) Värvimine ja katmine

Väikese ja keskmise suurusega silindri automaatse veepõhise värvipinnakattega liinide abil, et saavutada automaatne robotlaadimine ja mahalaadimine ning automaatne pihustamine, projekteerimisvõimsus 4000 tükki vahetuse kohta;
Meil on ka poolautomaatne suurte balloonide värvimise tootmisliin, mis töötab jõukettaga ja mille projekteerimisvõimsus on 60 kasti ühe vahetuse kohta.

(5) Testimine

Meil on esmaklassilised kontrolliseadmed ja katsestendid, et tagada silindri jõudlus vastavus nõuetele.

 

 

We are one of the best hydraulic cylinder manufacturers. We can offer comprehensive hydraulic cylinders. We also provide corresponding põllumajanduslikud käigukastid. Oleme eksportinud oma tooteid klientidele üle maailma ja teeninud hea maine tänu meie suurepärasele tootekvaliteedile ja müügijärgsele teenindusele. Me tervitame kliente kodus ja välismaal, et võtta meiega ühendust, et pidada läbirääkimisi äri, vahetada teavet ja teha meiega koostööd!

 

Tehke ekskursioon meie VR-tehases:

Tehke ekskursioon meie VR-tehases koos järgmisega

Kuidas töötab kahveltõstuki hüdrosilinder?

Hüdrosilindri kasutamine:

Hüdrosilindri kaks põhitüüpi ja tööpõhimõtted:

    etET