50SD10-22 Solenoid Directional Valve

The 50sd10-22 solenoid directional valve is a cutting-edge component that enhances fluid control in various industrial applications. With its advanced features, precise functionality, and reliable performance, this solenoid directional valve offers optimal fluid control, improving efficiency and productivity. Let’s delve into this indispensable equipment’s key characteristics, usage methods, and maintenance guidelines.

The 50sd10-22 solenoid directional valve is a reliable and versatile component that optimizes fluid control in industrial applications. This solenoid directional valve improves efficiency and productivity with its robust construction, versatile functionality, precise control, and reliable performance. By following proper usage methods and conducting routine maintenance, you can maximize the performance and longevity of this essential equipment. Incorporate the 50sd10-22 solenoid directional valve into your industrial systems to achieve accurate fluid control, streamline operations, and enhance overall productivity.

30SD10-21 Solenoid Directional Valve Characteristics:

  • Robust Construction: The 50sd10-22 solenoid directional valve boasts a complete design, employing high-quality materials and meticulous engineering. Its sturdy construction ensures durability and longevity, even in demanding industrial environments.
  • Versatile Functionality: This solenoid directional valve provides versatile functionality, making it suitable for various applications. It effectively controls the direction of fluid flow, enabling precise and efficient operation in different industrial systems.
  • Precise Control: With its exceptional precision, the 50sd10-22 solenoid directional valve delivers accurate control over fluid flow. It allows for precise regulation and adjustment of fluid direction and pressure, optimizing industrial processes’ overall performance and efficiency.
  • Reliable Performance: This solenoid directional valve offers reliable performance, ensuring consistent and repeatable results. Its dependable operation enhances productivity and reduces the risk of system failures or interruptions.

50SD10-22 Solenoid Directional Valve Parameter:

Rated pressure350 bar (5075 psi)
Proof pressure525 bar (7612 psi)
Peak flow75.7 L/min (20 gpm)
Internal Leakage≤ 0.15 mL/min(3 drops /min)@350 bar
Coil Duty RatingContinuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20℃E-coil1.7A at 12VDC; 0.85A at 24VDC
D-coil1.67A at 12VDC; 0.83A at 24VDC
Minimum pull-in voltage85% of nominal at 350 bar
CavityVC10-2
FluidMineral-based or synthetics with lubricating properties
Fluid temperature range ℃-54 to 107 ℃ (Polyurethane seals)
-40 to 100 ℃ (Buna N seals)
-26 to 204 ℃ (Fluorocarbon seals)
Viscosity range7.4 to 420 mm2/s
Degree of contaminationThe minimum pollution level is ISO4406 level 18/16/13, and level 15/13/11 is recommended to prolong the service life

50SD10-22 Solenoid Directional Valve Advantages:

• Continuous-duty rated coil
• Efficient wet-armature construction
• Cartridges are voltage interchangeable
• Optional waterproof E-Coils rated up to IP69K
• Industry common cavity
• Hardened parts for long life and low leakage

Usage Method Of 50SD10-22 Solenoid Directional Valve:

  • System Integration: Integrate the 50sd10-22 solenoid directional valve into the fluid control system by following the manufacturer’s guidelines and specifications. Ensure proper alignment and connection between the valve and other system components to achieve optimal performance.
  • Electrical Connection: Establish a secure electrical connection for the solenoid directional valve. Refer to the provided wiring diagram and ensure correct polarity to prevent any electrical malfunctions. Adhere to safety guidelines while working with electrical connections.
  • Fluid Flow Direction Control: Adjust the solenoid directional valve to control the direction of fluid flow. The valve typically features a lever or actuator that allows for manual adjustment. Alternatively, it can be integrated into an automated control system for remote operation.
  • Pressure Adjustment: Utilize the solenoid directional valve to regulate fluid pressure within the system. By adjusting the valve’s settings, you can attain the desired pressure levels for optimal performance and efficiency.

How To Change Delta Shower Valve Cartridge?

Changing the Delta shower valve cartridge is a relatively straightforward process that can be done with a few basic tools. Follow the step-by-step instructions below to replace the cartridge:

  1. Gather The Necessary Tools: You will need an adjustable wrench, pliers, and a screwdriver (Phillips or flat-head) for this task.
  2. Turn Off The Water Supply: Locate the main water shut-off valve for your home and turn it off to cut off the water supply to the shower. This step is crucial to prevent water from flowing when you remove the cartridge.
  3. Remove The Handle: Start by removing the handle of the shower valve. Look for a screw or set screw on the handle and use a screwdriver or Allen wrench to loosen and remove it. Once the screw is removed, gently pull the handle away from the valve to expose the cartridge.
  4. Remove The Cartridge Retaining Clip: Depending on the model of your Delta shower valve, there may be a retaining clip securing the cartridge in place. Locate the clip and use pliers to carefully remove it. Be cautious not to damage the clip during removal.
  5. Pull Out The Cartridge: With the retaining clip removed, you can now pull the cartridge straight out from the valve body. It may require a bit of force, but be careful not to twist or bend the cartridge during extraction.
  6. Install The New Cartridge: Take the new Delta shower valve cartridge and align it with the valve body. Make sure it is inserted straight and fully seated. Apply gentle pressure to push it into place until it is firmly positioned.
  7. Reassemble The Valve: Once the new cartridge is in place, reattach the retaining clip to secure it. Ensure the clip is properly engaged and holds the cartridge securely.
  8. Reinstall The Handle: Slide the shower handle back onto the valve stem and tighten the screw or set screw to secure it in place. Test the handle to ensure it operates smoothly and without any excessive play.
  9. Turn On The Water Supply: Return to the main water shut-off valve and turn it back on to restore the water supply to the shower.
  10. Check For Leaks: Turn on the shower and let the water flow to check for any leaks around the valve. If you notice any leaks, tighten the connections or consider replacing any worn-out seals or gaskets.

Tehtaan kapasiteetti ja kapasiteetti:

(1) Kokoonpano

Meillä on ensiluokkainen riippumaton tutkimus- ja kehitystyön kokoonpanoalusta. Hydraulisylinterien tuotantopajassa on neljä puoliautomaattista nostosylinterin kokoonpanolinjaa ja yksi automaattinen kallistussylinterin kokoonpanolinja, joiden suunniteltu vuotuinen tuotantokapasiteetti on 1 miljoona kappaletta. Erikoissylinterin työpaja on varustettu erilaisilla eritelmillä puoliautomaattisen puhdistusasennuksen kokoonpanojärjestelmällä, jonka suunniteltu vuotuinen tuotantokapasiteetti on 200 000, ja se on varustettu kuuluisilla CNC-työstölaitteilla, työstökeskuksella, korkean tarkkuuden sylinterin käsittelyyn tarkoitetuilla erityislaitteilla, robottihitsauskoneella, automaattisella puhdistuslaitteella, automaattisella sylinterin kokoonpanokoneella ja automaattisella maalaustuotantolinjalla. Olemassa olevat kriittiset laitteet yli 300 sarjaa (sarjaa). Laiteresurssien optimaalinen kohdentaminen ja tehokas käyttö varmistavat tuotteiden tarkkuusvaatimukset ja täyttävät tuotteiden laatuvaatimukset.

(2) Koneistus

Työstöpaja on varustettu räätälöidyllä kaltevalla kiskosorvauskeskuksella, työstökeskuksella, suurnopeus-hiontakoneella, hitsausrobotilla ja muilla vastaavilla laitteilla, joilla voidaan käsitellä sylinteriputkia, joiden sisähalkaisija on enintään 400 mm ja enimmäispituus on 6 metriä.

(3) Hitsaus

(4) Maalaus ja pinnoitus

Pienillä ja keskisuurilla sylinterin automaattisilla vesipohjaisilla maalipinnoituslinjoilla automaattisen robotin lastaus- ja purku- ja automaattisen ruiskutuksen saavuttamiseksi, suunnittelukapasiteetti on 4000 kappaletta vuorossa;
Meillä on myös puoliautomaattinen maalauslinja suurille sylintereille, joka toimii voimaketjulla ja jonka suunnittelukapasiteetti on 60 laatikkoa työvuorossa.

(5) Testaus

Meillä on ensiluokkaiset tarkastustilat ja testialustat, joilla varmistetaan, että sylinterin suorituskyky täyttää vaatimukset.

 

 

We are one of the best hydraulic cylinder manufacturers. We can offer comprehensive hydraulic cylinders. We also provide corresponding maatalousvaihteistot. We have exported our products to clients worldwide and earned a good reputation because of our superior product quality and after-sales service. We welcome customers at home and abroad to contact us to negotiate business, exchange information, and tehdä yhteistyötä kanssamme!

 

Tutustu VR-tehtaaseemme:

Tutustu VR-tehtaaseemme seuraavalla kierroksella

Miten haarukkatrukin hydraulisylinteri toimii?

Hydraulisylinteri Sovellus:

Hydraulisylinterin kaksi perustyyppiä ja toimintaperiaatteet:

    fiFI