{"id":2206,"date":"2023-11-01T03:57:46","date_gmt":"2023-11-01T03:57:46","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2206"},"modified":"2023-11-01T03:57:47","modified_gmt":"2023-11-01T03:57:47","slug":"4wrke-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/fr\/produit\/4wrke-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2215\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrke-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The 4WRKE series pilot-operated proportional directional hydraulic valve is a cutting-edge hydraulic component designed to provide superior precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRKE series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRKE series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4wrke series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Commande proportionnelle pilot\u00e9e<\/li>\n<\/ol>\n<ul>\n<li>The 4WRKE series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>Cette fonctionnalit\u00e9 garantit un contr\u00f4le pr\u00e9cis et r\u00e9actif, ce qui am\u00e9liore les performances du syst\u00e8me, r\u00e9duit la consommation d'\u00e9nergie et accro\u00eet la productivit\u00e9.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Commande directionnelle polyvalente<\/li>\n<\/ol>\n<ul>\n<li>Cette vanne offre un contr\u00f4le polyvalent de la direction du fluide hydraulique, ce qui la rend adapt\u00e9e \u00e0 une large gamme d'applications.<\/li>\n<li>Il permet l'activation et la d\u00e9sactivation en douceur des composants hydrauliques tels que les cylindres, les moteurs et les actionneurs dans diff\u00e9rentes directions, am\u00e9liorant ainsi la flexibilit\u00e9 et l'adaptabilit\u00e9 du syst\u00e8me.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Capacit\u00e9 de d\u00e9bit \u00e9lev\u00e9e<\/li>\n<\/ol>\n<ul>\n<li>The 4WRKE series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Sa construction robuste garantit des performances fiables m\u00eame dans des conditions exigeantes, assurant un contr\u00f4le de d\u00e9bit constant et efficace.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Efficacit\u00e9 \u00e9nerg\u00e9tique<\/li>\n<\/ol>\n<ul>\n<li>Gr\u00e2ce \u00e0 l'int\u00e9gration d'une commande proportionnelle pilot\u00e9e, cette vanne minimise les pertes de charge et optimise la consommation d'\u00e9nergie.<\/li>\n<li>Cela contribue \u00e0 r\u00e9duire la consommation d'\u00e9nergie, ce qui engendre des \u00e9conomies et des avantages environnementaux.<\/li>\n<\/ul>\n<h2><strong>4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"10\" align=\"left\" valign=\"middle\"><strong>G\u00e9n\u00e9ral<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">Taille<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">10<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">16<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">25<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">27<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">32<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">Installation and commissioning guidelines<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">facultatif, de pr\u00e9f\u00e9rence horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Plage de temp\u00e9rature de stockage<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">\u00b0C<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u2013 20 \u00a0to + 80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Plage de temp\u00e9rature ambiante<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">\u00b0C<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">-20 \u00a0to + 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Poids<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">kg<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">8.7<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">11.2<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">16.8<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">20<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">37.2<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\" align=\"left\" valign=\"middle\"><strong>Hydraulique\u00a0<\/strong>( measured at p=100bar,with HLP46 at \u03d1oil =40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Pression de service<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">-Pilot control valve<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">25 \u00a0to 315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\" width=\"82\">-Main valve<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Port \u00a0P A B<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">bar<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 315<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 350<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 350<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 210<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 350<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">Up to 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Pression de retour<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Port T<\/p>\n<p>(Pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Internal<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Static \uff1c 10<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\" width=\"82\">External<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">bar<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 315<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 250<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 250<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 210<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">Up to 250<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">Up to 250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Port Y<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Static &lt; 10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Nominal flow qVnom \u00b110% at \u0394p=10bar<br \/>\n(\u0394p = valve pressure differential)<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">25 \u00a0 \u00a0 \u00a0 \u00a050<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">&#8211; \u00a0 \u00a0 \u00a0 \u00a0125<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">&#8211; \u00a0 \u00a0 \u00a0 \u00a0220<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">&#8211; \u00a0 \u00a0 \u00a0 \u00a0&#8211;<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">&#8211; \u00a0 \u00a0 \u00a0 \u00a0440<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\" width=\"82\">100<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">180<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">350<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">500<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">600<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Flow of main valve (max. permissible)<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">170<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">460<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">870<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">1000<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">1600<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">3000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Pilot oil flow at port X or Y with a step form of input signal from 0 to 100 % (315 bar)<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">4.1<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">8.5<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">11.7<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">11.7<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">13<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\" width=\"82\">13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">Fluide sous pression<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Mineral oil(HL,HLP)to DIN 51 524 Phosphate ester (HFD-R)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Plage de temp\u00e9rature du fluide<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">\u00b0C<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">10 to 80, preferably 40 to 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Plage de viscosit\u00e9<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">20 to 380, preferably 30 to 45<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Degr\u00e9 de contamination<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\"><\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Maximum permissible degree of contamination: NAS 1638.<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x = 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Pilot control valve<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Class 7<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">x = 5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\" width=\"82\">Vanne principale<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Class 9<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">x = 7<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Hyst\u00e9r\u00e8se<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u22641<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Sensibilit\u00e9 de la r\u00e9ponse<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u22640,5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"10\" align=\"left\" valign=\"middle\"><strong>\u00c9lectrique<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">Type de tension<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">raccordement \u00e9lectrique<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Plug-in connector to DIN EN175 201-804<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\" width=\"82\">Power, max.<\/td>\n<td align=\"left\" valign=\"middle\" width=\"82\">W<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">72 (average = 24W)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\" width=\"82\">\u00e9lectronique de contr\u00f4le<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Integrated into the valve<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve with electrical position feedback of the main spool, used to control the size and direction of the liquid flow<br \/>\n\u2022 Sub-plate mounting type connection structure, connection size conforms to ISO 4401 standard<br \/>\n\u2022 Spring centred main spool<br \/>\n\u2022 With integrated proportional amplifier<br \/>\n\u2022 The pilot control is a single-stage proportional directional valve<br \/>\n\u2022 The pilot valve is a threaded proportional solenoid, and the coil can be disassembled separately<\/p>\n<h2><strong>Usage Method Of 4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>\u00c9valuation du syst\u00e8me<\/strong><\/li>\n<\/ol>\n<ul>\n<li>\u00c9valuez votre syst\u00e8me hydraulique et identifiez les exigences sp\u00e9cifiques en mati\u00e8re de d\u00e9bit et de contr\u00f4le directionnel.<\/li>\n<li>Determine if the 4WRKE Series Valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>S\u00e9lection de vannes<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRKE Series Valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Tenez compte de facteurs tels que le d\u00e9bit maximal, la pression nominale, le temps de r\u00e9ponse et les conditions de fonctionnement.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Installation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Suivez attentivement les instructions d'installation du fabricant, en veillant \u00e0 un alignement correct et \u00e0 une fixation s\u00e9curis\u00e9e de la vanne.<\/li>\n<li>R\u00e9alisez des raccords \u00e9tanches et assurez-vous du bon alignement du sens d'\u00e9coulement pour garantir des performances optimales.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Connexion du signal de commande<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Raccordez les fils de signal de commande de la vanne \u00e0 un dispositif de commande appropri\u00e9, tel qu'un amplificateur proportionnel ou une unit\u00e9 de commande \u00e9lectronique.<\/li>\n<li>Assurez-vous d'un c\u00e2blage correct et d'une compatibilit\u00e9 entre la vanne et le dispositif de commande pour une r\u00e9gulation pr\u00e9cise et r\u00e9active.<\/li>\n<\/ul>\n<h2><strong>How To Clean Hydraulic Valve Lifters?<\/strong><\/h2>\n<p>Cleaning hydraulic valve lifters is an important maintenance task that helps ensure proper engine performance and reduce noise caused by dirt or debris buildup. Here&#8217;s a step-by-step guide on how to clean hydraulic valve lifters:<\/p>\n<ol>\n<li>Rassemblez les outils et mat\u00e9riaux n\u00e9cessaires :\n<ul>\n<li>New engine oil<\/li>\n<li>Chiffons ou serviettes propres<\/li>\n<li>Engine degreaser or parts cleaner<\/li>\n<li>Small brush or toothbrush<\/li>\n<li>Plastic container or tray<\/li>\n<\/ul>\n<\/li>\n<li>Pr\u00e9paration:\n<ul>\n<li>Allow the engine to cool down completely before starting the cleaning process.<\/li>\n<li>Remove the valve cover or covers to access the hydraulic valve lifters. Refer to the manufacturer&#8217;s instructions or a repair manual for your specific engine to locate and remove the valve cover(s) properly.<\/li>\n<\/ul>\n<\/li>\n<li>Removal of Hydraulic Valve Lifters:\n<ul>\n<li>Identify the hydraulic valve lifters in the engine.<\/li>\n<li>One at a time, carefully remove the hydraulic valve lifters from their respective locations. Depending on your engine, you may need to remove other components or parts to access the lifters.<\/li>\n<li>Place each lifter in a plastic container or tray in the order they were removed. This will help ensure they are reinstalled correctly later.<\/li>\n<\/ul>\n<\/li>\n<li>Cleaning the Lifters:\n<ul>\n<li>Pour a small amount of engine degreaser or parts cleaner into a container.<\/li>\n<li>Place one hydraulic valve lifter into the container, ensuring it is fully submerged in the cleaner.<\/li>\n<li>Allow the lifter to soak for the recommended duration specified by the cleaner manufacturer. This usually ranges from 15 minutes to an hour.<\/li>\n<li>Use a small brush or toothbrush to gently scrub the lifter&#8217;s exterior surfaces, removing any deposits or dirt.<\/li>\n<li>Rinse the lifter thoroughly with clean water to remove any remaining cleaner or debris.<\/li>\n<li>Dry the lifter using a clean rag or towel. Ensure there are no traces of moisture before reinstallation.<\/li>\n<\/ul>\n<\/li>\n<li>Reinstallation:\n<ul>\n<li>Apply a small amount of fresh engine oil to the cleaned lifter&#8217;s exterior surface.<\/li>\n<li>Carefully place the lifter back into its original position in the engine, ensuring it is properly aligned and seated.<\/li>\n<li>Repeat the cleaning process for each hydraulic valve lifter, following the same steps.<\/li>\n<li>Once all the lifters are cleaned and reinstalled, make sure they are secured properly.<\/li>\n<\/ul>\n<\/li>\n<li>Remontage:\n<ul>\n<li>Reinstall the valve cover(s) according to the manufacturer&#8217;s instructions.<\/li>\n<li>Double-check that all components and parts are properly secured and tightened.<\/li>\n<\/ul>\n<\/li>\n<li>Test and Inspection:\n<ul>\n<li>Start the engine and let it run for a few minutes to ensure proper operation and to allow the lifters to refill with oil.<\/li>\n<li>Listen for any abnormal noises or ticking sounds that could indicate further issues.<\/li>\n<li>If noise or performance problems persist, it may be necessary to consult a professional mechanic for further diagnosis and repair.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Capacit\u00e9 de l'usine :<\/strong><\/h2>\n<h3>(1) Assemblage<\/h3>\n<p>Nous disposons d'une plateforme d'assemblage ind\u00e9pendante de recherche et d\u00e9veloppement de premier ordre. Notre atelier de production de v\u00e9rins hydrauliques dispose de quatre lignes d'assemblage semi-automatiques de v\u00e9rins de levage et d'une ligne d'assemblage automatique de v\u00e9rins d'inclinaison, pour une capacit\u00e9 de production annuelle pr\u00e9vue d'un million de pi\u00e8ces. L'atelier de v\u00e9rins sp\u00e9ciaux est \u00e9quip\u00e9 d'un syst\u00e8me d'assemblage de nettoyage semi-automatique de diverses sp\u00e9cifications, d'une capacit\u00e9 de production annuelle pr\u00e9vue de 200\u00a0000 pi\u00e8ces et dispose d'\u00e9quipements d'usinage CNC de pointe, d'un centre d'usinage, d'\u00e9quipements sp\u00e9ciaux d'usinage de haute pr\u00e9cision, d'une machine de soudage robotis\u00e9e, d'une machine de nettoyage automatique, d'une machine d'assemblage automatique de v\u00e9rins et d'une ligne de peinture automatique. Nous disposons de plus de 300 \u00e9quipements critiques. L'allocation optimale et l'utilisation efficace des ressources garantissent la pr\u00e9cision et la qualit\u00e9 des produits.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Usinage<\/h3>\n<p>L'atelier d'usinage est \u00e9quip\u00e9 d'un centre de tournage sur rail inclin\u00e9 personnalis\u00e9, d'un centre d'usinage, d'une machine \u00e0 honer \u00e0 grande vitesse, d'un robot de soudage et d'autres \u00e9quipements connexes, qui peuvent traiter des tubes cylindriques d'un diam\u00e8tre int\u00e9rieur maximal de 400 mm et d'une longueur maximale de 6 m\u00e8tres.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Soudage<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Peinture et rev\u00eatement<\/h3>\n<p>Avec des lignes de rev\u00eatement de peinture \u00e0 base d'eau automatiques \u00e0 cylindre de petite et moyenne taille, pour r\u00e9aliser le chargement et le d\u00e9chargement automatiques par robot et la pulv\u00e9risation automatique, la capacit\u00e9 de conception est de 4 000 pi\u00e8ces par \u00e9quipe ;<br \/>\nNous disposons \u00e9galement d'une ligne de production de peinture semi-automatique pour gros cylindres, aliment\u00e9e par une cha\u00eene de traction, d'une capacit\u00e9 de conception de 60 caisses par \u00e9quipe.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Essais<\/h3>\n<p>Nous disposons d'installations d'inspection et de bancs d'essai de premier ordre pour garantir que les performances de la bouteille sont conformes aux exigences.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Nous sommes l'un des meilleurs fabricants de v\u00e9rins hydrauliques. Nous proposons une gamme compl\u00e8te de v\u00e9rins hydrauliques. Nous fournissons \u00e9galement les v\u00e9rins correspondants. <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">bo\u00eetes de vitesses agricoles<\/a>Nous exportons nos produits dans le monde entier et nous avons acquis une excellente r\u00e9putation gr\u00e2ce \u00e0 la qualit\u00e9 sup\u00e9rieure de nos produits et \u00e0 notre service apr\u00e8s-vente. Nous invitons nos clients, nationaux et internationaux, \u00e0 nous contacter pour n\u00e9gocier, \u00e9changer des informations et\u2026 <a href=\"https:\/\/www.hydraulic-cylinders.net\/fr\/contact-us\/\">coop\u00e9rer avec nous<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRKE Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRKE series pilot-operated proportional directional hydraulic valve is a cutting-edge hydraulic component designed to provide superior precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRKE series pilot-operated proportional directional [&hellip;]<\/p>","protected":false},"featured_media":2216,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2206","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/product\/2206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/comments?post=2206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/media\/2216"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/media?parent=2206"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/product_brand?post=2206"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/product_cat?post=2206"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/fr\/wp-json\/wp\/v2\/product_tag?post=2206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}