{"id":2055,"date":"2023-10-25T08:13:01","date_gmt":"2023-10-25T08:13:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2055"},"modified":"2023-10-25T08:13:02","modified_gmt":"2023-10-25T08:13:02","slug":"weh-series-directional-hydraulic-valves-of-pilot-operated","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/hu\/termek\/weh-series-directional-hydraulic-valves-of-pilot-operated\/","title":{"rendered":"WEH Series Directional Hydraulic Valves Of Pilot Operated"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2071\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/weh-series-directional-hydraulic-valves-of-pilot-operated-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility.<\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are reliable, high-performance components that empower operators with precise control and efficient fluid management in hydraulic systems. With their pilot-operated design, exceptional directional control, a wide range of configurations, and high flow capacity, these valves offer the reliability and versatility required in various industries. Following the recommended usage methods and adhering to regular maintenance practices, the WEH series valves will continue delivering\u00a0exceptional performance. Upgrade your hydraulic system with the WEH series directional hydraulic valves operated and experience the benefits of precision, control, and reliability.<\/p>\n<p>WEH Series Directional Hydraulic Valves Of Pilot Operated Key Characteristics:<\/p>\n<ul>\n<li>Pil\u00f3ta \u00e1ltal vez\u00e9relt kialak\u00edt\u00e1s:\n<ul>\n<li>The WEH series valves utilize a pilot-operated design, which enhances their responsiveness and control accuracy.<\/li>\n<li>This design enables the valves to handle high-pressure applications, ensuring optimal performance easily.<\/li>\n<\/ul>\n<\/li>\n<li>Ir\u00e1ny\u00edtott vez\u00e9rl\u00e9s:\n<ul>\n<li>These hydraulic valves excel in providing precise directional control of hydraulic fluid.<\/li>\n<li>A kezel\u0151k k\u00f6nnyen kezelhetik a folyad\u00e9k\u00e1raml\u00e1st, \u00e9s ir\u00e1ny\u00edthatj\u00e1k azt a hidraulikus rendszeren bel\u00fcli k\u00fcl\u00f6nb\u00f6z\u0151 m\u0171k\u00f6dtet\u0151kh\u00f6z vagy alkatr\u00e9szekhez.<\/li>\n<\/ul>\n<\/li>\n<li>Wide Range of Configurations:\n<ul>\n<li>The WEH series valves are available in various configurations, including various sizes, flow rates, and pressure ratings.<\/li>\n<li>This versatility allows them to be tailored to specific application requirements and system specifications.<\/li>\n<\/ul>\n<\/li>\n<li>Nagy \u00e1raml\u00e1si kapacit\u00e1s:\n<ul>\n<li>These valves are designed to handle high flow rates, making them suitable for applications that demand substantial fluid flow.<\/li>\n<li>Optimaliz\u00e1lt bels\u0151 \u00e1tj\u00e1r\u00f3ik \u00e9s robusztus konstrukci\u00f3juk minim\u00e1lis nyom\u00e1ses\u00e9st \u00e9s hat\u00e9kony folyad\u00e9kkezel\u00e9st biztos\u00edtanak.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">WEH10 \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Switching pilot oil volume\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08AC and DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0\u00a0ms<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">60<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">55<\/td>\n<td align=\"left\" valign=\"middle\">15<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0\u00a0 ms<\/td>\n<td align=\"left\" valign=\"middle\">35<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">75<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">70<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0 \u00a0ms<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">40<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">20<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">HC\u3001HD\u3001HK\u3001HZ\u3001HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">S\u00faly<\/td>\n<td align=\"left\" valign=\"middle\">Single solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Double solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">7.1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Switching time regulator kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">1.0<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Reducing valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH16&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V)bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">3-position valve \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply ( apply to \u00a0C\u3001Z\u3001F\u3001 G\u3001<br \/>\nH\u3001P\u3001T\u3001V) bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 9.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">WEH25&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">95<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight\u00a0 \u00a0kg<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG32<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH32&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0 \u00a03-position valve \u00a0\u00a0 8.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a015<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range \u00a0\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">29.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">58.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">( DC \uff1a50\uff0cAC \uff1a60)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C\u3001D\u3001K\u3001Z\u3001YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"pro_d\">\n<div class=\"wrap\">\n<div class=\"content sidebar-content clearfix\">\n<div class=\"right-cont\">\n<div class=\"show-model-bobx\">\n<div class=\"bottom\">\n<div class=\"val-bar-box\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Advantages:<\/strong><\/h2>\n<p>\u2022 Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Wet DC or AC solenoid (optional)<br \/>\n\u2022 With manual emergency control<br \/>\n\u2022 Electropneumatic connection as single or center connection<br \/>\n\u2022 Spring or hydraulic alignment or bias<\/p>\n<h2><strong>Usage Method Of WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Rendszerintegr\u00e1ci\u00f3:<\/strong>\n<ul>\n<li>Identify the optimal location for installing the WEH series valves within the hydraulic system, considering the desired flow path and control requirements.<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg a rendszer nyom\u00e1s- \u00e9s \u00e1raml\u00e1si specifik\u00e1ci\u00f3ival val\u00f3 kompatibilit\u00e1sr\u00f3l.<\/li>\n<li>Szerelje fel biztons\u00e1gosan a szelepeket megfelel\u0151 konzolok vagy szerel\u00e9si tartoz\u00e9kok seg\u00edts\u00e9g\u00e9vel.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pilot Control Setup:<\/strong>\n<ul>\n<li>Connect the pilot control lines to the designated ports on the valves, following the manufacturer&#8217;s instructions.<\/li>\n<li>Ensure proper sizing and routing of the pilot lines to maintain optimal control signal integrity.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Folyad\u00e9kcsatlakoz\u00e1sok:<\/strong>\n<ul>\n<li>V\u00e1lasszon kompatibilis hidraulikus szerelv\u00e9nyeket \u00e9s t\u00f6ml\u0151ket a biztons\u00e1gos \u00e9s sziv\u00e1rg\u00e1smentes csatlakoz\u00e1sok \u00e9rdek\u00e9ben.<\/li>\n<li>A telep\u00edt\u00e9s sor\u00e1n k\u00f6vesse a gy\u00e1rt\u00f3 utas\u00edt\u00e1sait a megfelel\u0151 nyomat\u00e9k\u00e9rt\u00e9kek tekintet\u00e9ben.<\/li>\n<li>Haszn\u00e1ljon megfelel\u0151 menett\u00f6m\u00edt\u0151ket vagy szalagot a megb\u00edzhat\u00f3 t\u00f6m\u00edt\u00e9sek biztos\u00edt\u00e1s\u00e1hoz.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Szab\u00e1lyoz\u00e1s \u00e9s be\u00e1ll\u00edt\u00e1s:<\/strong>\n<ul>\n<li>To operate the WEH series valves, utilize the recommended control method, such as manual levers or electrical controls.<\/li>\n<li>Adjust the valves&#8217; settings to achieve the desired flow direction and rates, ensuring optimal performance.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Do Hydraulic Valve Lifters Work?<\/strong><\/h2>\n<p>Hydraulic valve lifters, also known as hydraulic tappets or hydraulic lash adjusters, play a vital role in the proper operation of an internal combustion engine. They are responsible for maintaining the proper clearance, or &#8220;lash,&#8221; between the engine&#8217;s camshaft and valve train components. Here&#8217;s an overview of how hydraulic valve lifters work:<\/p>\n<ol>\n<li><strong>Szerkezet:<\/strong>\n<ul>\n<li>Hydraulic valve lifters are small cylindrical devices typically made of metal.<\/li>\n<li>They are between the camshaft and the engine&#8217;s valve train components, such as the pushrods, rocker arms, or overhead cam followers.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Hydraulic Operation:<\/strong>\n<ul>\n<li>Inside the hydraulic valve lifter, a small piston mechanism operates based on hydraulic pressure.<\/li>\n<li>The lifter is filled with hydraulic fluid, typically engine oil, which acts as a working fluid.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Camshaft Interaction:<\/strong>\n<ul>\n<li>The camshaft has lobes or eccentric shapes that push against the lifters as it rotates.<\/li>\n<li>As the camshaft lobe comes into contact with the lifter, it applies a force that compresses its internal piston.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Adjustment:<\/strong>\n<ul>\n<li>When the lifter&#8217;s piston is compressed, it pushes the hydraulic fluid out of the lifter through a small orifice.<\/li>\n<li>This hydraulic fluid is expelled into the engine&#8217;s oil galleries or passages.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Compensation:<\/strong>\n<ul>\n<li>The expelled hydraulic fluid creates a hydraulic cushion or &#8220;spring&#8221; effect, compensating for any clearance or lash between the camshaft lobe and the valve train components.<\/li>\n<li>This compensation eliminates excessive clearance and ensures that the valve train remains in constant contact with the camshaft lobes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Maintenance of Lash:<\/strong>\n<ul>\n<li>If there is excessive clearance or lash in the valve train due to wear or other factors, the lifter&#8217;s internal piston will extend further to maintain the necessary hydraulic pressure.<\/li>\n<li>This extended position allows the lifter to take up the additional clearance, thus maintaining proper valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Oil Pressure and Lubrication:<\/strong>\n<ul>\n<li>The hydraulic valve lifters rely on the engine&#8217;s oil pressure for proper operation.<\/li>\n<li>The oil pump circulates oil through the engine, and the lifters receive a continuous oil supply to maintain hydraulic pressure and lubrication.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>A gy\u00e1r kapacit\u00e1sa \u00e9s kapacit\u00e1sa:<\/strong><\/h2>\n<h3>(1) \u00d6sszeszerel\u00e9s<\/h3>\n<p>Els\u0151 oszt\u00e1ly\u00fa f\u00fcggetlen kutat\u00e1si \u00e9s fejleszt\u00e9si \u00f6sszeszerel\u00e9si platformmal rendelkez\u00fcnk. A hidraulikus hengergy\u00e1rt\u00f3 m\u0171hely n\u00e9gy f\u00e9lautomata emel\u0151henger-\u00f6sszeszerel\u0151 sorral \u00e9s egy automata billen\u0151henger-\u00f6sszeszerel\u0151 sorral rendelkezik, tervezett \u00e9ves gy\u00e1rt\u00e1si kapacit\u00e1sa 1 milli\u00f3 darab. A speci\u00e1lis henger m\u0171hely k\u00fcl\u00f6nb\u00f6z\u0151 specifik\u00e1ci\u00f3j\u00fa f\u00e9lautomata tiszt\u00edt\u00f3 \u00f6sszeszerel\u0151 rendszerrel van felszerelve, amelynek tervezett \u00e9ves termel\u00e9si kapacit\u00e1sa 200.000, \u00e9s h\u00edres CNC megmunk\u00e1l\u00f3 berendez\u00e9ssel, megmunk\u00e1l\u00f3 k\u00f6zponttal, nagy pontoss\u00e1g\u00fa hengerfeldolgoz\u00f3 speci\u00e1lis berendez\u00e9ssel, robothegeszt\u0151 g\u00e9ppel, automatikus tiszt\u00edt\u00f3g\u00e9ppel, automatikus henger \u00f6sszeszerel\u0151 g\u00e9ppel \u00e9s automatikus fest\u00e9si gy\u00e1rt\u00f3sorral van felszerelve. A megl\u00e9v\u0151 kritikus berendez\u00e9sek t\u00f6bb mint 300 k\u00e9szlet (k\u00e9szlet). A berendez\u00e9sek er\u0151forr\u00e1sainak optim\u00e1lis eloszt\u00e1sa \u00e9s hat\u00e9kony felhaszn\u00e1l\u00e1sa biztos\u00edtja a term\u00e9kek pontoss\u00e1gi k\u00f6vetelm\u00e9nyeit \u00e9s megfelel a term\u00e9kek min\u0151s\u00e9gi ig\u00e9nyeinek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Megmunk\u00e1l\u00e1s<\/h3>\n<p>A megmunk\u00e1l\u00f3m\u0171hely egyedi, ferde s\u00edneszterg\u00e1l\u00f3 k\u00f6zponttal, megmunk\u00e1l\u00f3k\u00f6zponttal, nagysebess\u00e9g\u0171 h\u00f3nol\u00f3g\u00e9ppel, hegeszt\u0151robottal \u00e9s egy\u00e9b kapcsol\u00f3d\u00f3 berendez\u00e9sekkel van felszerelve, amelyek legfeljebb 400 mm bels\u0151 \u00e1tm\u00e9r\u0151j\u0171 \u00e9s legfeljebb 6 m\u00e9ter hossz\u00fa hengercs\u00f6vek megmunk\u00e1l\u00e1s\u00e1ra k\u00e9pesek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Hegeszt\u00e9s<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Fest\u00e9s \u00e9s bevonatol\u00e1s<\/h3>\n<p>Kis \u00e9s k\u00f6zepes m\u00e9ret\u0171 hengeres automatikus v\u00edzb\u00e1zis\u00fa fest\u00e9kbevon\u00f3 sorokkal, az automatikus robot be- \u00e9s kirakod\u00e1s, valamint az automatikus permetez\u00e9s megval\u00f3s\u00edt\u00e1s\u00e1hoz, a tervez\u00e9si kapacit\u00e1s m\u0171szakonk\u00e9nt 4000 darab;<br \/>\nRendelkez\u00fcnk egy f\u00e9lautomata fest\u00e9kgy\u00e1rt\u00f3sorral is nagym\u00e9ret\u0171 palackokhoz, amelyet egy er\u0151\u00e1tviteli l\u00e1nc hajt, m\u0171szakonk\u00e9nt 60 doboz tervez\u00e9si kapacit\u00e1ssal.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Tesztel\u00e9s<\/h3>\n<p>Els\u0151 oszt\u00e1ly\u00fa ellen\u0151rz\u0151 l\u00e9tes\u00edtm\u00e9nyekkel \u00e9s tesztpadokkal rendelkez\u00fcnk annak biztos\u00edt\u00e1s\u00e1ra, hogy a palack teljes\u00edtm\u00e9nye megfeleljen a k\u00f6vetelm\u00e9nyeknek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Mi vagyunk az egyik legjobb hidraulikus henger gy\u00e1rt\u00f3. \u00c1tfog\u00f3 hidraulikus hengereket k\u00edn\u00e1lunk. Megfelel\u0151 szolg\u00e1ltat\u00e1sokat is biztos\u00edtunk. <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">mez\u0151gazdas\u00e1gi sebess\u00e9gv\u00e1lt\u00f3k<\/a>Term\u00e9keinket vil\u00e1gszerte export\u00e1ltuk \u00fcgyfeleinknek, \u00e9s kiv\u00e1l\u00f3 term\u00e9kmin\u0151s\u00e9g\u00fcnknek \u00e9s \u00e9rt\u00e9kes\u00edt\u00e9s ut\u00e1ni szolg\u00e1ltat\u00e1sunknak k\u00f6sz\u00f6nhet\u0151en j\u00f3 h\u00edrnevet szerezt\u00fcnk. Szeretettel v\u00e1rjuk belf\u00f6ldi \u00e9s k\u00fclf\u00f6ldi \u00fcgyfeleinket, hogy \u00fczleti t\u00e1rgyal\u00e1sok, inform\u00e1ci\u00f3csere \u00e9s egy\u00e9b lehet\u0151s\u00e9gek c\u00e9lj\u00e1b\u00f3l kapcsolatba l\u00e9pjenek vel\u00fcnk. <a href=\"https:\/\/www.hydraulic-cylinders.net\/hu\/contact-us\/\">egy\u00fcttm\u0171k\u00f6dni vel\u00fcnk<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WEH Series Directional Hydraulic Valves Of Pilot Operated The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility. The WEH series directional hydraulic valves of pilot operated are [&hellip;]<\/p>","protected":false},"featured_media":2072,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2055","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product\/2055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/comments?post=2055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/media\/2072"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/media?parent=2055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_brand?post=2055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_cat?post=2055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_tag?post=2055"}],"curies":[{"name":"munkaf\u00fczet","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}