{"id":2079,"date":"2023-10-26T06:23:21","date_gmt":"2023-10-26T06:23:21","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2079"},"modified":"2023-10-26T06:23:22","modified_gmt":"2023-10-26T06:23:22","slug":"gweh-series-explosion-proof-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/hu\/termek\/gweh-series-explosion-proof-directional-hydraulic-valve\/","title":{"rendered":"GWEH Series Explosion-proof Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>GWEH Series Explosion-proof Directional Hydraulic Valve <\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2095\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/gweh-series-explosion-proof-directional-hydraulic-valve-1-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The GWEH series explosion-proof directional hydraulic valve is an innovative solution designed to provide optimal safety and precise control in hydraulic systems operating in hazardous environments. With its explosion-proof features, reliable performance, and advanced functionalities, this valve offers enhanced safety measures, efficient fluid flow control, and compatibility with various industrial applications.<\/p>\n<p>The GWEH series explosion-proof directional hydraulic valve is a reliable and efficient solution for industries operating in hazardous environments. With its explosion-proof design, precise directional control, versatility, and high performance, this valve ensures safety and control in hydraulic systems. Following the recommended usage methods and adhering to regular maintenance practices, the GWEH series valve delivers safe and efficient operation in explosive atmospheres. Upgrade your hydraulic system with the GWEH series explosion-proof directional hydraulic valve and experience enhanced safety, optimal fluid flow control, and reliable performance.<\/p>\n<p>GWEH Series Explosion-proof Directional Hydraulic Valve Key Characteristics:<\/p>\n<ul>\n<li>Explosion-proof Design:\n<ul>\n<li>The GWEH series valve is engineered with a robust explosion-proof design, ensuring safe operation in environments containing flammable gases or dust.<\/li>\n<li>It complies with stringent safety standards and certifications, minimizing the risk of ignition and ensuring the safety of personnel and equipment.<\/li>\n<\/ul>\n<\/li>\n<li>Ir\u00e1ny\u00edtott vez\u00e9rl\u00e9s:\n<ul>\n<li>This hydraulic valve provides precise directional control of fluid flow, allowing for the activation and deactivation of specific hydraulic actuators.<\/li>\n<li>It enables smooth and reliable operation of various hydraulic functions, such as cylinder extension and retraction or motor direction changes.<\/li>\n<\/ul>\n<\/li>\n<li>Versatility and Compatibility:\n<ul>\n<li>The GWEH series valve is highly versatile and compatible with various hydraulic systems and applications.<\/li>\n<li>It can seamlessly integrate into industrial machinery, mobile equipment, and automation systems operating in hazardous environments.<\/li>\n<\/ul>\n<\/li>\n<li>Nagy teljes\u00edtm\u00e9ny:\n<ul>\n<li>With its advanced design and high-quality construction, the GWEH series hydraulic valve delivers exceptional performance and reliability.<\/li>\n<li>It ensures consistent and precise control over fluid flow, contributing to efficient and optimized system operation.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>GWEH Series Explosion-proof Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/p>\n<p>(not apply to \u00a0C, Z, F, G, H, P, T, V)<\/td>\n<td colspan=\"1\" rowspan=\"3\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 7<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<br \/>\n( apply to \u00a0C, Z, F, G, H, P, T, V)<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">\u00a04.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Folyad\u00e9kh\u0151m\u00e9rs\u00e9klet-tartom\u00e1ny<\/td>\n<td colspan=\"1\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viszkozit\u00e1si tartom\u00e1ny<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Controlled quantity in commutating process<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">cm3<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04 2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u00e1r<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kisasszony<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u00a02-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kisasszony<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">3-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kisasszony<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">2-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kisasszony<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">25<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">20<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shortest switching time<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">L\/perc<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">HC, HD, HK, HZ and HY of hydraulic return shall be installed horizontally. The rest are arbitrary<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">G-..WEH16..\/6B2.. \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B \u00a0bar<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0With internal pilot oil drain is impossible<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0bar<\/p>\n<p>With internal pilot oil supply\u00a0 bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 14<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<br \/>\n( apply to \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0 bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm2 \/s 2<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-Spring-centering 3-position valve \u00a0\u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-2-position valve \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily\u3002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shorter switching time \u00a0 L\/min<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Weight of the valve \u00a0kg<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">about 10.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Specifik\u00e1ci\u00f3k<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">G-H-&#8230;WEH25..\/6B2&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">T. port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0With internal pilot oil drain is impossible<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y port<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0bar<\/p>\n<p>With internal pilot oil supply\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a018<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0\u00a0\u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a018<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Folyad\u00e9k<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm2 \/s 2<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">2,8-t\u00f3l 500-ig<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-Spring-centering 3-position valve \u00a0\u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-2-position valve \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Be\u00e9p\u00edt\u00e9si poz\u00edci\u00f3<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily\u3002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shorter switching time \u00a0 L\/min<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Weight of the valve \u00a0kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 19<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>GWEH Series Explosion-proof Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Directional valve directional the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Two-position four-way or three-position four-way<br \/>\n\u2022 Installation face follows DIN 24340 A, ISO 4401, and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Cser\u00e9lje ki a tekercset olaj kiereszt\u00e9se n\u00e9lk\u00fcl<\/p>\n<h2><strong>Usage Method Of GWEH Series Explosion-proof Directional Hydraulic Valve <\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li>Hazardous Area Assessment:\n<ul>\n<li>Conduct a thorough assessment of the hazardous area to identify the specific explosion-proof requirements and classification.<\/li>\n<li>Determine the appropriate safety measures and precautions needed to comply with the regulations.<\/li>\n<\/ul>\n<\/li>\n<li>Szelepv\u00e1laszt\u00e1s:\n<ul>\n<li>Select the GWEH Series Valve with the suitable specifications, considering factors such as pressure ratings, flow capacity, and voltage requirements.<\/li>\n<li>Ensure compatibility with the hydraulic system and the specific hazardous environment.<\/li>\n<\/ul>\n<\/li>\n<li>Telep\u00edt\u00e9s:\n<ul>\n<li>Follow the manufacturer&#8217;s instructions for proper installation of the GWEH Series Valve in the hydraulic system.<\/li>\n<li>Ensure secure mounting and proper electrical connections, adhering to the recommended torque values and wiring guidelines.<\/li>\n<\/ul>\n<\/li>\n<li>Control and Activation:\n<ul>\n<li>Utilize the recommended control method, such as electrical signals or remote activation, to operate the GWEH Series Valve.<\/li>\n<li>Connect the valve to a suitable power source and control system, following the provided wiring diagrams.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Does A Hydraulic Control Valve Work?<\/strong><\/h2>\n<p>A hydraulic control valve is a critical component in hydraulic systems that regulates the flow and direction of hydraulic fluid to control the operation of hydraulic actuators. It enables precise control over various hydraulic functions, such as extending or retracting cylinders, controlling motor speed and direction, or adjusting the flow rate of hydraulic fluid. Here&#8217;s an overview of how a hydraulic control valve works:<\/p>\n<ol>\n<li><strong>Szelepszerkezet:<\/strong>\n<ul>\n<li>A hydraulic control valve typically consists of a valve body, spools or poppets, and various internal passages.<\/li>\n<li>The valve body contains inlet and outlet ports for fluid connection and chambers that direct the flow.<\/li>\n<li>The spools or poppets are movable elements within the valve body that control the flow paths and connect the appropriate ports.<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u00c1raml\u00e1sszab\u00e1lyoz\u00e1s:<\/strong>\n<ul>\n<li>The hydraulic control valve regulates the flow of hydraulic fluid by opening and closing specific flow paths within the valve.<\/li>\n<li>The position of the spools or poppets determines which ports are connected and allows fluid to flow in the desired direction.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Ir\u00e1ny\u00edtott vez\u00e9rl\u00e9s:<\/strong>\n<ul>\n<li>Hydraulic control valves provide directional control by selectively connecting or blocking fluid flow to different hydraulic actuators.<\/li>\n<li>By adjusting the position of the spools or poppets, the valve determines which actuator receives fluid and in which direction it moves.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Actuation Methods:<\/strong>\n<ul>\n<li>Hydraulic control valves can be actuated using manual levers, mechanical linkages, solenoids, or pilot pressure control.<\/li>\n<li>Manual control valves are operated by moving the levers or handles to position the spools or poppets.<\/li>\n<li>Solenoid-controlled valves use electromagnetic coils to actuate the valve, allowing for remote or automated control.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Control Modes:<\/strong>\n<ul>\n<li>Hydraulic control valves offer different control modes, such as 2-way, 3-way, or 4-way control.<\/li>\n<li>A 2-way control valve controls flow in one direction, allowing or blocking fluid flow.<\/li>\n<li>A 3-way control valve has three ports and can control the flow between two ports while blocking the third.<\/li>\n<li>A 4-way control valve has four ports and can route fluid between two actuator ports while blocking the other two.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pressure Compensation:<\/strong>\n<ul>\n<li>Some hydraulic control valves are equipped with pressure compensation features to maintain a consistent flow rate despite changes in system pressure.<\/li>\n<li>These valves adjust the flow passages based on pressure differentials, allowing for precise control regardless of varying operating conditions.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Feedback and Control Loops:<\/strong>\n<ul>\n<li>Advanced hydraulic control valves may incorporate feedback mechanisms, such as position or pressure sensors, to provide feedback to a control system.<\/li>\n<li>This feedback enables closed-loop control, where the system can monitor and adjust the valve&#8217;s position or flow based on desired setpoints or operating conditions.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>A gy\u00e1r kapacit\u00e1sa \u00e9s kapacit\u00e1sa:<\/strong><\/h2>\n<h3>(1) \u00d6sszeszerel\u00e9s<\/h3>\n<p>Els\u0151 oszt\u00e1ly\u00fa f\u00fcggetlen kutat\u00e1si \u00e9s fejleszt\u00e9si \u00f6sszeszerel\u00e9si platformmal rendelkez\u00fcnk. A hidraulikus hengergy\u00e1rt\u00f3 m\u0171hely n\u00e9gy f\u00e9lautomata emel\u0151henger-\u00f6sszeszerel\u0151 sorral \u00e9s egy automata billen\u0151henger-\u00f6sszeszerel\u0151 sorral rendelkezik, tervezett \u00e9ves gy\u00e1rt\u00e1si kapacit\u00e1sa 1 milli\u00f3 darab. A speci\u00e1lis henger m\u0171hely k\u00fcl\u00f6nb\u00f6z\u0151 specifik\u00e1ci\u00f3j\u00fa f\u00e9lautomata tiszt\u00edt\u00f3 \u00f6sszeszerel\u0151 rendszerrel van felszerelve, amelynek tervezett \u00e9ves termel\u00e9si kapacit\u00e1sa 200.000, \u00e9s h\u00edres CNC megmunk\u00e1l\u00f3 berendez\u00e9ssel, megmunk\u00e1l\u00f3 k\u00f6zponttal, nagy pontoss\u00e1g\u00fa hengerfeldolgoz\u00f3 speci\u00e1lis berendez\u00e9ssel, robothegeszt\u0151 g\u00e9ppel, automatikus tiszt\u00edt\u00f3g\u00e9ppel, automatikus henger \u00f6sszeszerel\u0151 g\u00e9ppel \u00e9s automatikus fest\u00e9si gy\u00e1rt\u00f3sorral van felszerelve. A megl\u00e9v\u0151 kritikus berendez\u00e9sek t\u00f6bb mint 300 k\u00e9szlet (k\u00e9szlet). A berendez\u00e9sek er\u0151forr\u00e1sainak optim\u00e1lis eloszt\u00e1sa \u00e9s hat\u00e9kony felhaszn\u00e1l\u00e1sa biztos\u00edtja a term\u00e9kek pontoss\u00e1gi k\u00f6vetelm\u00e9nyeit \u00e9s megfelel a term\u00e9kek min\u0151s\u00e9gi ig\u00e9nyeinek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Megmunk\u00e1l\u00e1s<\/h3>\n<p>A megmunk\u00e1l\u00f3m\u0171hely egyedi, ferde s\u00edneszterg\u00e1l\u00f3 k\u00f6zponttal, megmunk\u00e1l\u00f3k\u00f6zponttal, nagysebess\u00e9g\u0171 h\u00f3nol\u00f3g\u00e9ppel, hegeszt\u0151robottal \u00e9s egy\u00e9b kapcsol\u00f3d\u00f3 berendez\u00e9sekkel van felszerelve, amelyek legfeljebb 400 mm bels\u0151 \u00e1tm\u00e9r\u0151j\u0171 \u00e9s legfeljebb 6 m\u00e9ter hossz\u00fa hengercs\u00f6vek megmunk\u00e1l\u00e1s\u00e1ra k\u00e9pesek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Hegeszt\u00e9s<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Fest\u00e9s \u00e9s bevonatol\u00e1s<\/h3>\n<p>Kis \u00e9s k\u00f6zepes m\u00e9ret\u0171 hengeres automatikus v\u00edzb\u00e1zis\u00fa fest\u00e9kbevon\u00f3 sorokkal, az automatikus robot be- \u00e9s kirakod\u00e1s, valamint az automatikus permetez\u00e9s megval\u00f3s\u00edt\u00e1s\u00e1hoz, a tervez\u00e9si kapacit\u00e1s m\u0171szakonk\u00e9nt 4000 darab;<br \/>\nRendelkez\u00fcnk egy f\u00e9lautomata fest\u00e9kgy\u00e1rt\u00f3sorral is nagym\u00e9ret\u0171 palackokhoz, amelyet egy er\u0151\u00e1tviteli l\u00e1nc hajt, m\u0171szakonk\u00e9nt 60 doboz tervez\u00e9si kapacit\u00e1ssal.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Tesztel\u00e9s<\/h3>\n<p>Els\u0151 oszt\u00e1ly\u00fa ellen\u0151rz\u0151 l\u00e9tes\u00edtm\u00e9nyekkel \u00e9s tesztpadokkal rendelkez\u00fcnk annak biztos\u00edt\u00e1s\u00e1ra, hogy a palack teljes\u00edtm\u00e9nye megfeleljen a k\u00f6vetelm\u00e9nyeknek.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Mi vagyunk az egyik legjobb hidraulikus henger gy\u00e1rt\u00f3. \u00c1tfog\u00f3 hidraulikus hengereket k\u00edn\u00e1lunk. Megfelel\u0151 szolg\u00e1ltat\u00e1sokat is biztos\u00edtunk. <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">mez\u0151gazdas\u00e1gi sebess\u00e9gv\u00e1lt\u00f3k<\/a>Term\u00e9keinket vil\u00e1gszerte export\u00e1ltuk \u00fcgyfeleinknek, \u00e9s kiv\u00e1l\u00f3 term\u00e9kmin\u0151s\u00e9g\u00fcnknek \u00e9s \u00e9rt\u00e9kes\u00edt\u00e9s ut\u00e1ni szolg\u00e1ltat\u00e1sunknak k\u00f6sz\u00f6nhet\u0151en j\u00f3 h\u00edrnevet szerezt\u00fcnk. Szeretettel v\u00e1rjuk belf\u00f6ldi \u00e9s k\u00fclf\u00f6ldi \u00fcgyfeleinket, hogy \u00fczleti t\u00e1rgyal\u00e1sok, inform\u00e1ci\u00f3csere \u00e9s egy\u00e9b lehet\u0151s\u00e9gek c\u00e9lj\u00e1b\u00f3l kapcsolatba l\u00e9pjenek vel\u00fcnk. <a href=\"https:\/\/www.hydraulic-cylinders.net\/hu\/contact-us\/\">egy\u00fcttm\u0171k\u00f6dni vel\u00fcnk<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>GWEH Series Explosion-proof Directional Hydraulic Valve The GWEH series explosion-proof directional hydraulic valve is an innovative solution designed to provide optimal safety and precise control in hydraulic systems operating in hazardous environments. With its explosion-proof features, reliable performance, and advanced functionalities, this valve offers enhanced safety measures, efficient fluid flow control, and compatibility with various [&hellip;]<\/p>","protected":false},"featured_media":2094,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2079","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product\/2079","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/comments?post=2079"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/media\/2094"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/media?parent=2079"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_brand?post=2079"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_cat?post=2079"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/hu\/wp-json\/wp\/v2\/product_tag?post=2079"}],"curies":[{"name":"munkaf\u00fczet","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}