{"id":2055,"date":"2023-10-25T08:13:01","date_gmt":"2023-10-25T08:13:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2055"},"modified":"2023-10-25T08:13:02","modified_gmt":"2023-10-25T08:13:02","slug":"weh-series-directional-hydraulic-valves-of-pilot-operated","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/it\/prodotto\/weh-series-directional-hydraulic-valves-of-pilot-operated\/","title":{"rendered":"WEH Series Directional Hydraulic Valves Of Pilot Operated"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2071\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/weh-series-directional-hydraulic-valves-of-pilot-operated-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility.<\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are reliable, high-performance components that empower operators with precise control and efficient fluid management in hydraulic systems. With their pilot-operated design, exceptional directional control, a wide range of configurations, and high flow capacity, these valves offer the reliability and versatility required in various industries. Following the recommended usage methods and adhering to regular maintenance practices, the WEH series valves will continue delivering\u00a0exceptional performance. Upgrade your hydraulic system with the WEH series directional hydraulic valves operated and experience the benefits of precision, control, and reliability.<\/p>\n<p>WEH Series Directional Hydraulic Valves Of Pilot Operated Key Characteristics:<\/p>\n<ul>\n<li>Progettazione a pilotaggio remoto:\n<ul>\n<li>The WEH series valves utilize a pilot-operated design, which enhances their responsiveness and control accuracy.<\/li>\n<li>This design enables the valves to handle high-pressure applications, ensuring optimal performance easily.<\/li>\n<\/ul>\n<\/li>\n<li>Controllo direzionale:\n<ul>\n<li>These hydraulic valves excel in providing precise directional control of hydraulic fluid.<\/li>\n<li>Operators can easily manage fluid flow and direct it to different actuators or components within the hydraulic system.<\/li>\n<\/ul>\n<\/li>\n<li>Wide Range of Configurations:\n<ul>\n<li>The WEH series valves are available in various configurations, including various sizes, flow rates, and pressure ratings.<\/li>\n<li>This versatility allows them to be tailored to specific application requirements and system specifications.<\/li>\n<\/ul>\n<\/li>\n<li>Elevata capacit\u00e0 di flusso:\n<ul>\n<li>These valves are designed to handle high flow rates, making them suitable for applications that demand substantial fluid flow.<\/li>\n<li>Their optimized internal passages and robust construction ensure minimal pressure drop and efficient fluid management.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifiche<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">WEH10 \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Porto T<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Porta Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fluido<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Olio minerale, estere fosfatico<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Da 2,8 a 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Switching pilot oil volume\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08AC and DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0\u00a0ms<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">60<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">55<\/td>\n<td align=\"left\" valign=\"middle\">15<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0\u00a0 ms<\/td>\n<td align=\"left\" valign=\"middle\">35<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">75<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">70<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0 \u00a0ms<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">40<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">20<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Posizione di installazione<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">HC\u3001HD\u3001HK\u3001HZ\u3001HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Peso<\/td>\n<td align=\"left\" valign=\"middle\">Single solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Double solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">7.1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Switching time regulator kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">1.0<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Reducing valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifiche<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH16&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Porto T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Porta Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V)bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">3-position valve \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply ( apply to \u00a0C\u3001Z\u3001F\u3001 G\u3001<br \/>\nH\u3001P\u3001T\u3001V) bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fluido<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Olio minerale, estere fosfatico<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Da 2,8 a 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Posizione di installazione<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 9.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifiche<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">WEH25&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Porto T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Porta Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fluido<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Olio minerale, estere fosfatico<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">95<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Posizione di installazione<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight\u00a0 \u00a0kg<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG32<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifiche<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH32&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Porto T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Porta Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0 \u00a03-position valve \u00a0\u00a0 8.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a015<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fluido<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Olio minerale, estere fosfatico<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range \u00a0\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Da 2,8 a 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">29.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">58.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">( DC \uff1a50\uff0cAC \uff1a60)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Posizione di installazione<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C\u3001D\u3001K\u3001Z\u3001YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"pro_d\">\n<div class=\"wrap\">\n<div class=\"content sidebar-content clearfix\">\n<div class=\"right-cont\">\n<div class=\"show-model-bobx\">\n<div class=\"bottom\">\n<div class=\"val-bar-box\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Advantages:<\/strong><\/h2>\n<p>\u2022 Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Wet DC or AC solenoid (optional)<br \/>\n\u2022 With manual emergency control<br \/>\n\u2022 Electropneumatic connection as single or center connection<br \/>\n\u2022 Spring or hydraulic alignment or bias<\/p>\n<h2><strong>Usage Method Of WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Integrazione di sistema:<\/strong>\n<ul>\n<li>Identify the optimal location for installing the WEH series valves within the hydraulic system, considering the desired flow path and control requirements.<\/li>\n<li>Assicurare la compatibilit\u00e0 con le specifiche di pressione e portata del sistema.<\/li>\n<li>Mount the valves securely using appropriate brackets or mounting accessories.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pilot Control Setup:<\/strong>\n<ul>\n<li>Connect the pilot control lines to the designated ports on the valves, following the manufacturer&#8217;s instructions.<\/li>\n<li>Ensure proper sizing and routing of the pilot lines to maintain optimal control signal integrity.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Collegamenti fluidi:<\/strong>\n<ul>\n<li>Selezionare raccordi idraulici e tubi flessibili compatibili per collegamenti sicuri e senza perdite.<\/li>\n<li>Seguire le istruzioni del produttore per i valori di coppia corretti durante il processo di installazione.<\/li>\n<li>Per garantire una tenuta affidabile, utilizzare sigillanti o nastri adatti per filettature.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Controllo e regolazione:<\/strong>\n<ul>\n<li>To operate the WEH series valves, utilize the recommended control method, such as manual levers or electrical controls.<\/li>\n<li>Adjust the valves&#8217; settings to achieve the desired flow direction and rates, ensuring optimal performance.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Do Hydraulic Valve Lifters Work?<\/strong><\/h2>\n<p>Hydraulic valve lifters, also known as hydraulic tappets or hydraulic lash adjusters, play a vital role in the proper operation of an internal combustion engine. They are responsible for maintaining the proper clearance, or &#8220;lash,&#8221; between the engine&#8217;s camshaft and valve train components. Here&#8217;s an overview of how hydraulic valve lifters work:<\/p>\n<ol>\n<li><strong>Structure:<\/strong>\n<ul>\n<li>Hydraulic valve lifters are small cylindrical devices typically made of metal.<\/li>\n<li>They are between the camshaft and the engine&#8217;s valve train components, such as the pushrods, rocker arms, or overhead cam followers.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Hydraulic Operation:<\/strong>\n<ul>\n<li>Inside the hydraulic valve lifter, a small piston mechanism operates based on hydraulic pressure.<\/li>\n<li>The lifter is filled with hydraulic fluid, typically engine oil, which acts as a working fluid.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Camshaft Interaction:<\/strong>\n<ul>\n<li>The camshaft has lobes or eccentric shapes that push against the lifters as it rotates.<\/li>\n<li>As the camshaft lobe comes into contact with the lifter, it applies a force that compresses its internal piston.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Adjustment:<\/strong>\n<ul>\n<li>When the lifter&#8217;s piston is compressed, it pushes the hydraulic fluid out of the lifter through a small orifice.<\/li>\n<li>This hydraulic fluid is expelled into the engine&#8217;s oil galleries or passages.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Compensation:<\/strong>\n<ul>\n<li>The expelled hydraulic fluid creates a hydraulic cushion or &#8220;spring&#8221; effect, compensating for any clearance or lash between the camshaft lobe and the valve train components.<\/li>\n<li>This compensation eliminates excessive clearance and ensures that the valve train remains in constant contact with the camshaft lobes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Maintenance of Lash:<\/strong>\n<ul>\n<li>If there is excessive clearance or lash in the valve train due to wear or other factors, the lifter&#8217;s internal piston will extend further to maintain the necessary hydraulic pressure.<\/li>\n<li>This extended position allows the lifter to take up the additional clearance, thus maintaining proper valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Oil Pressure and Lubrication:<\/strong>\n<ul>\n<li>The hydraulic valve lifters rely on the engine&#8217;s oil pressure for proper operation.<\/li>\n<li>The oil pump circulates oil through the engine, and the lifters receive a continuous oil supply to maintain hydraulic pressure and lubrication.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Capacit\u00e0 e capacit\u00e0 della fabbrica:<\/strong><\/h2>\n<h3>(1) Montaggio<\/h3>\n<p>Disponiamo di una piattaforma di assemblaggio indipendente di ricerca e sviluppo di prima classe. L'officina di produzione di cilindri idraulici dispone di quattro linee di assemblaggio semiautomatiche per cilindri di sollevamento e una linea di assemblaggio automatica per cilindri di inclinazione, con una capacit\u00e0 produttiva annua progettata di 1 milione di pezzi. L'officina per cilindri speciali \u00e8 dotata di un sistema di assemblaggio semiautomatico per la pulizia con diverse specifiche, con una capacit\u00e0 produttiva annua progettata di 200.000 pezzi e dotata di rinomate macchine per lavorazioni meccaniche CNC, un centro di lavoro, attrezzature speciali per la lavorazione di cilindri ad alta precisione, una macchina per saldatura robotizzata, una macchina per la pulizia automatica, una macchina per l'assemblaggio automatico dei cilindri e una linea di produzione per la verniciatura automatica. Sono disponibili oltre 300 set di attrezzature critiche. L'allocazione ottimale e l'uso efficiente delle risorse delle attrezzature garantiscono i requisiti di precisione dei prodotti e ne soddisfano le elevate esigenze di qualit\u00e0.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Lavorazione<\/h3>\n<p>L'officina di lavorazione \u00e8 dotata di un centro di tornitura su rotaia inclinata personalizzato, di un centro di lavorazione, di una levigatrice ad alta velocit\u00e0, di un robot di saldatura e di altre attrezzature correlate, in grado di gestire la lavorazione di tubi cilindrici con un diametro interno massimo di 400 mm e una lunghezza massima di 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Saldatura<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Verniciatura e rivestimento<\/h3>\n<p>Con linee automatiche di verniciatura a base d'acqua a cilindro di piccole e medie dimensioni, per realizzare il carico e lo scarico automatico con robot e la spruzzatura automatica, la capacit\u00e0 di progettazione \u00e8 di 4000 pezzi per turno;<br \/>\nDisponiamo anche di una linea di produzione semiautomatica di vernici per cilindri di grandi dimensioni alimentata da una catena di potenza, con una capacit\u00e0 di progettazione di 60 casse per turno.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test<\/h3>\n<p>Disponiamo di strutture di ispezione e banchi di prova di prim'ordine per garantire che le prestazioni del cilindro siano conformi ai requisiti.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Siamo uno dei migliori produttori di cilindri idraulici. Offriamo una gamma completa di cilindri idraulici. Forniamo anche i relativi componenti. <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">riduttori agricoli<\/a>Abbiamo esportato i nostri prodotti a clienti in tutto il mondo e ci siamo guadagnati un'ottima reputazione grazie alla qualit\u00e0 superiore dei nostri prodotti e al servizio post-vendita. Invitiamo i clienti nazionali e internazionali a contattarci per negoziare affari, scambiare informazioni e <a href=\"https:\/\/www.hydraulic-cylinders.net\/it\/contact-us\/\">collaborare con noi<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WEH Series Directional Hydraulic Valves Of Pilot Operated The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility. The WEH series directional hydraulic valves of pilot operated are [&hellip;]<\/p>","protected":false},"featured_media":2072,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2055","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/product\/2055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/comments?post=2055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/media\/2072"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/media?parent=2055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/product_brand?post=2055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/product_cat?post=2055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/it\/wp-json\/wp\/v2\/product_tag?post=2055"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}