{"id":2207,"date":"2023-11-01T06:24:32","date_gmt":"2023-11-01T06:24:32","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2207"},"modified":"2023-11-01T06:24:33","modified_gmt":"2023-11-01T06:24:33","slug":"4wrpeh-series-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/lt\/produktas\/4wrpeh-series-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRPEH Series Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRPEH Series Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2217\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrpeh-series-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The 4WRPEH series proportional directional hydraulic valve is an advanced hydraulic component designed to deliver exceptional precision and control in hydraulic systems. With its innovative proportional directional control technology, this valve enables accurate flow regulation and smooth directional changes.<\/p>\n<p>The 4WRPEH series proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile functionality, and enhanced efficiency. Its proportional directional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRPEH series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRPEH series proportional directional hydraulic valve.<\/p>\n<p>4WRPEH Series Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Proportional Directional Control:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRPEH series valve utilizes state-of-the-art proportional directional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>\u0160i funkcija u\u017etikrina tiksl\u0173 ir greit\u0105 valdym\u0105, tod\u0117l pager\u0117ja sistemos na\u0161umas, suma\u017e\u0117ja energijos suvartojimas ir padid\u0117ja na\u0161umas.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Universalus funkcionalumas:<\/li>\n<\/ol>\n<ul>\n<li>\u0160is vo\u017etuvas si\u016blo universal\u0173 hidraulinio skys\u010dio krypties valdym\u0105, tod\u0117l tinka \u012fvairioms reikm\u0117ms.<\/li>\n<li>Tai leid\u017eia skland\u017eiai \u012fjungti ir i\u0161jungti hidraulinius komponentus, tokius kaip cilindrai, varikliai ir pavaros, skirtingomis kryptimis, taip padidinant sistemos lankstum\u0105 ir pritaikomum\u0105.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Didelis srautas:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRPEH series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Tvirta konstrukcija u\u017etikrina patikim\u0105 veikim\u0105 net ir sud\u0117tingomis s\u0105lygomis, u\u017etikrindama nuosekl\u0173 ir efektyv\u0173 srauto valdym\u0105.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Precise Metering:<\/li>\n<\/ol>\n<ul>\n<li>With its proportional control technology, this valve offers precise metering of hydraulic fluid, allowing for accurate control and regulation of flow rates.<\/li>\n<li>This precision enhances overall system performance and ensures precise movements of hydraulic actuators.<\/li>\n<\/ul>\n<h2><strong>4WRPEH Series Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<p><strong>NG6<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Bendra<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Dizainas<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Spool valve, direct operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u012ejungimas<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ry\u0161io tipas<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Subplate mounting, porting pattern according to ISO 4401-03-02-0-05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Montavimo pad\u0117tis<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Aplinkos temperat\u016bros diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Svoris<\/td>\n<td align=\"left\" valign=\"middle\">Kg<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">about 2.75<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hidraulinis\u00a0<\/strong>\u00a0 (measured at p=100bar, with HLP46 at \u03d1oil = 40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Sl\u0117ginis skystis<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP)to DIN 51 524<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Klampumo diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">rekomenduojama<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">maks. leid\u017eiamas<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Sl\u0117ginio skys\u010dio temperat\u016bros diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">nuo -20 iki +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Did\u017eiausias leid\u017eiamas sl\u0117ginio skys\u010dio u\u017eter\u0161tumo laipsnis Grynumo klas\u0117 pagal ISO 4406 (c)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">18\/16\/13 klas\u0117<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow (\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\">2<\/td>\n<td align=\"left\" valign=\"middle\">4<\/td>\n<td align=\"left\" valign=\"middle\">12<\/td>\n<td align=\"left\" valign=\"middle\">24<\/td>\n<td align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maks. darbinis sl\u0117gis<\/td>\n<td align=\"left\" valign=\"middle\">baras<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Port \u00a0A\u3001B\u3001P\uff1a315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maks. sl\u0117gis<\/td>\n<td align=\"left\" valign=\"middle\">baras<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">T prievadas: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;150<\/td>\n<td align=\"left\" valign=\"middle\">&lt;180<\/td>\n<td align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;500<\/td>\n<td align=\"left\" valign=\"middle\">&lt;900;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td align=\"left\" valign=\"middle\">&lt;450;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Statinis\/Dinaminis<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Histerez\u0117<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">ms<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electric, control electronics integrated in the valve<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Apsaugos laipsnis<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Plug-in connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V (ripple max. 2)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">nput, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (<sub>ID-E<\/sub>)<br \/>\nTerminal E (<sub>ID-E<\/sub>)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (<sub>UTest<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT signal 4 &#8230; (12) &#8230; 20 mA on external load 200 &#8230; 500 \u03a9maximum<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4 &#8230; (12) &#8230; 20mA (output)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Adjustment<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Calibrated before delivery, see characteristic curves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Bendra<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Dizainas<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Spool valve, directly operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u012ejungimas<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ry\u0161io tipas<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Plate port, porting pattern (ISO 4401-05-04-0-05)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Montavimo pad\u0117tis<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Aplinkyb\u0117s, temperat\u016bros diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Svoris<\/td>\n<td align=\"left\" valign=\"middle\">Kg<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">about 7.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Hydraulic \u00a0 (measured with HLP 46, \u03d1oil =40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Sl\u0117ginis skystis<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic oil according to DIN 51524&#8230;535<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Klampumo diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">rekomenduojama<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. permitted<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Sl\u0117ginio skys\u010dio temperat\u016bros diapazonas<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">nuo -20 iki +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. admissible degree of contamination of the hydraulic fluid,cleanliness class according to ISO 4406 (c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">18\/16\/13 klas\u0117<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow(\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<td colspan=\"2\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maks. darbinis sl\u0117gis<\/td>\n<td align=\"left\" valign=\"middle\">baras<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0P A B: 315<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maks. sl\u0117gis<\/td>\n<td align=\"left\" valign=\"middle\">baras<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">T prievadas: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;1200<\/td>\n<td colspan=\"2\">&lt;1500<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;600<\/td>\n<td colspan=\"2\">&lt;600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Statinis\/Dinaminis<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Histerez\u0117<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">ms<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Electric, control electronics integrated in the valve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Apsaugos laipsnis<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">IP65(with mating connector mounted and locked )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Mating connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ripple max. 2 VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (I<sub>D-E<\/sub>)<br \/>\nTerminal E (I<sub>D-E<\/sub>)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (U<sub>Test<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;20 mA output<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0feedback<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRPEH Series Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Direct-acting servo solenoid valve with control piston and valve sleeve, with servo performance<br \/>\n\u2022 Single-side drive, optional with power-off safety function<br \/>\nControl solenoid with built-in feedback and integrated amplifier board (OBE), factory preset<br \/>\n\u2022 Electrical connection 6P+PE signal input differential amplifier with interface, input optional A1: \u00b110V, or interface F1: 4&#8230;20mA (Rsh =200\u03a9)<br \/>\n\u2022 Panel mounting, the mounting surface complies with ISO 4401-03-02<\/p>\n<h2><strong>Usage Method Of 4WRPEH Series Proportional Directional Hydraulic Valve <\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li>Sistemos vertinimas:<\/li>\n<\/ol>\n<ul>\n<li>\u012evertinkite savo hidraulin\u0119 sistem\u0105 ir nustatykite konkre\u010dius srauto ir krypties valdymo reikalavimus.<\/li>\n<li>Determine if the 4WRPEH series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Vo\u017etuvo pasirinkimas:<\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRPEH series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Atsi\u017evelkite \u012f tokius veiksnius kaip maksimalus srautas, sl\u0117gio lygis, atsako laikas ir eksploatavimo s\u0105lygos.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>\u012erengimas:<\/li>\n<\/ol>\n<ul>\n<li>Atid\u017eiai laikykit\u0117s gamintojo montavimo instrukcij\u0173, u\u017etikrindami tinkam\u0105 vo\u017etuvo sulygiavim\u0105 ir saug\u0173 pritvirtinim\u0105.<\/li>\n<li>Make leak-free connections and ensure correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Control Signal Connection:<\/li>\n<\/ol>\n<ul>\n<li>Prijunkite vo\u017etuvo valdymo signalo laidus prie tinkamo valdymo \u012ftaiso, pvz., proporcinio stiprintuvo arba elektroninio valdymo bloko.<\/li>\n<li>U\u017etikrinkite tinkam\u0105 laid\u0173 sujungim\u0105 ir suderinamum\u0105 tarp vo\u017etuvo ir valdymo \u012ftaiso, kad valdymas b\u016bt\u0173 tikslus ir greitas.<\/li>\n<\/ul>\n<h2><strong>How To Hook Two Hydraulic Valves Together?<\/strong><\/h2>\n<p>Hooking two hydraulic valves together requires careful consideration of the valve types, their functions, and the specific hydraulic system requirements. Here are general guidelines on how to hook two hydraulic valves together:<\/p>\n<ol>\n<li><strong>Identify Valve Types:<\/strong>\n<ul>\n<li>Determine the types of valves you are working with, such as directional control valves, pressure control valves, flow control valves, or any other specific valves required for your system.<\/li>\n<li>Ensure that both valves are compatible in terms of size, pressure ratings, flow capacity, and function.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Understand Valve Functions:<\/strong>\n<ul>\n<li>Familiarize yourself with the functions of each valve. For example, directional control valves regulate fluid flow direction, pressure control valves control system pressure, and flow control valves manage flow rates.<\/li>\n<li>Determine how the combination of these valves will contribute to achieving the desired hydraulic system operation.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Determine Valve Placement:<\/strong>\n<ul>\n<li>Decide where in the hydraulic system you want to install the two valves. Consider factors such as fluid flow path, pressure requirements, and the desired control sequence.<\/li>\n<li>Ensure that the valve placement allows for proper fluid flow and accessibility for maintenance and operation.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Connect Valve Ports:<\/strong>\n<ul>\n<li>Identify the inlet and outlet ports of each valve. These ports may be labeled or indicated in the valve documentation.<\/li>\n<li>Use appropriate hydraulic fittings, adapters, or connectors to connect the ports of the two valves together.<\/li>\n<li>Ensure a secure and leak-free connection by using suitable sealing materials, such as O-rings or thread sealants.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Consider Valve Interactions:<\/strong>\n<ul>\n<li>Evaluate how the interaction between the two valves will affect the hydraulic system&#8217;s overall performance.<\/li>\n<li>Ensure that the combined operation of the valves does not create conflicts or result in unintended consequences, such as pressure spikes, flow restrictions, or unintended movements.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Valdymo signalo integravimas:<\/strong>\n<ul>\n<li>If the valves require control signals, such as electrical or pneumatic signals, determine how these signals will be integrated.<\/li>\n<li>Connect the control signal lines of both valves to the appropriate control devices, such as hydraulic control modules, electronic control units, or manual control levers.<\/li>\n<li>Ensure proper wiring, compatibility, and synchronization between the control devices and the valves to achieve the desired control and coordination.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Test and Adjust:<\/strong>\n<ul>\n<li>After hooking the valves together, thoroughly test the hydraulic system to ensure proper operation.<\/li>\n<li>Monitor the system for any issues, such as leaks, excessive pressure drops, or unexpected behavior.<\/li>\n<li>Make necessary adjustments, such as fine-tuning control settings or modifying valve placement if required.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Gamyklos paj\u0117gumai ir talpa:<\/strong><\/h2>\n<h3>(1) Surinkimas<\/h3>\n<p>Turime pirmos klas\u0117s nepriklausom\u0105 tyrim\u0173 ir pl\u0117tros surinkimo platform\u0105. Hidraulini\u0173 cilindr\u0173 gamybos ceche yra keturios pusiau automatin\u0117s k\u0117limo cilindr\u0173 surinkimo linijos ir viena automatin\u0117 pakreipimo cilindr\u0173 surinkimo linija, kuri\u0173 projektinis metinis gamybos paj\u0117gumas yra 1 milijonas vienet\u0173. Speciali\u0173j\u0173 cilindr\u0173 ceche \u012frengta \u012fvairi\u0173 specifikacij\u0173 pusiau automatin\u0117 valymo surinkimo sistema, kurios projektinis metinis gamybos paj\u0117gumas yra 200 000 vienet\u0173, ir garsi CNC apdirbimo \u012franga, apdirbimo centras, didelio tikslumo cilindr\u0173 apdirbimo speciali \u012franga, robotinis suvirinimo aparatas, automatinis valymo aparatas, automatinis cilindr\u0173 surinkimo aparatas ir automatin\u0117 da\u017eymo gamybos linija. Esama daugiau nei 300 rinkini\u0173 (komplekt\u0173) kritin\u0117 \u012franga. Optimalus \u012frangos i\u0161tekli\u0173 paskirstymas ir efektyvus naudojimas u\u017etikrina gamini\u0173 tikslumo reikalavimus ir auk\u0161tus gamini\u0173 kokyb\u0117s poreikius.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Apdirbimas<\/h3>\n<p>Mechaninio apdirbimo ceche \u012frengtas pritaikytas nuo\u017eulnaus b\u0117gio tekinimo centras, apdirbimo centras, greitaeigis galandimo stakl\u0117s, suvirinimo robotas ir kita susijusi \u012franga, galinti apdirbti cilindrinius vamzd\u017eius, kuri\u0173 maksimalus vidinis skersmuo yra 400 mm, o maksimalus ilgis \u2013 6 metrai.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Suvirinimas<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Da\u017eymas ir dengimas<\/h3>\n<p>Su ma\u017eomis ir vidutinio dyd\u017eio cilindrin\u0117mis automatin\u0117mis vandens pagrindo da\u017e\u0173 dengimo linijomis, siekiant automatinio robot\u0173 pakrovimo ir i\u0161krovimo bei automatinio pur\u0161kimo, projektinis paj\u0117gumas yra 4000 vienet\u0173 per pamain\u0105;<br \/>\nTaip pat turime pusiau automatin\u0119 dideli\u0173 cilindr\u0173 da\u017e\u0173 gamybos linij\u0105, varom\u0105 grandin\u0117s, kurios projektinis na\u0161umas yra 60 d\u0117\u017ei\u0173 per pamain\u0105.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testavimas<\/h3>\n<p>Turime auk\u0161\u010diausios klas\u0117s patikros patalpas ir bandym\u0173 stendus, kad u\u017etikrintume, jog baliono veikimas atitinka reikalavimus.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Esame vienas geriausi\u0173 hidraulini\u0173 cilindr\u0173 gamintoj\u0173. Galime pasi\u016blyti i\u0161samius hidraulinius cilindrus. Taip pat teikiame atitinkamus <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">\u017eem\u0117s \u016bkio pavar\u0173 d\u0117\u017e\u0117s<\/a>Mes eksportuojame savo gaminius klientams visame pasaulyje ir peln\u0117me ger\u0105 reputacij\u0105 d\u0117l auk\u0161\u010diausios gamini\u0173 kokyb\u0117s ir aptarnavimo po pardavimo. Mes laukiame klient\u0173 \u0161alyje ir u\u017esienyje, norin\u010di\u0173 susisiekti su mumis der\u0117tis d\u0117l verslo, keistis informacija ir... <a href=\"https:\/\/www.hydraulic-cylinders.net\/lt\/contact-us\/\">bendradarbiauti su mumis<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRPEH Series Proportional Directional Hydraulic Valve The 4WRPEH series proportional directional hydraulic valve is an advanced hydraulic component designed to deliver exceptional precision and control in hydraulic systems. With its innovative proportional directional control technology, this valve enables accurate flow regulation and smooth directional changes. The 4WRPEH series proportional directional hydraulic valve empowers hydraulic systems [&hellip;]<\/p>","protected":false},"featured_media":2218,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2207","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/product\/2207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/comments?post=2207"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/media\/2218"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/media?parent=2207"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/product_brand?post=2207"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/product_cat?post=2207"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lt\/wp-json\/wp\/v2\/product_tag?post=2207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}