{"id":2055,"date":"2023-10-25T08:13:01","date_gmt":"2023-10-25T08:13:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2055"},"modified":"2023-10-25T08:13:02","modified_gmt":"2023-10-25T08:13:02","slug":"weh-series-directional-hydraulic-valves-of-pilot-operated","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/lv\/products\/weh-series-directional-hydraulic-valves-of-pilot-operated\/","title":{"rendered":"WEH Series Directional Hydraulic Valves Of Pilot Operated"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2071\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/weh-series-directional-hydraulic-valves-of-pilot-operated-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility.<\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are reliable, high-performance components that empower operators with precise control and efficient fluid management in hydraulic systems. With their pilot-operated design, exceptional directional control, a wide range of configurations, and high flow capacity, these valves offer the reliability and versatility required in various industries. Following the recommended usage methods and adhering to regular maintenance practices, the WEH series valves will continue delivering\u00a0exceptional performance. Upgrade your hydraulic system with the WEH series directional hydraulic valves operated and experience the benefits of precision, control, and reliability.<\/p>\n<p>WEH Series Directional Hydraulic Valves Of Pilot Operated Key Characteristics:<\/p>\n<ul>\n<li>Pilot Operated Design:\n<ul>\n<li>The WEH series valves utilize a pilot-operated design, which enhances their responsiveness and control accuracy.<\/li>\n<li>This design enables the valves to handle high-pressure applications, ensuring optimal performance easily.<\/li>\n<\/ul>\n<\/li>\n<li>Virziena vad\u012bba:\n<ul>\n<li>These hydraulic valves excel in providing precise directional control of hydraulic fluid.<\/li>\n<li>Operatori var viegli p\u0101rvald\u012bt \u0161\u0137idruma pl\u016bsmu un novirz\u012bt to uz da\u017e\u0101diem izpildmeh\u0101nismiem vai komponentiem hidrauliskaj\u0101 sist\u0113m\u0101.<\/li>\n<\/ul>\n<\/li>\n<li>Wide Range of Configurations:\n<ul>\n<li>The WEH series valves are available in various configurations, including various sizes, flow rates, and pressure ratings.<\/li>\n<li>This versatility allows them to be tailored to specific application requirements and system specifications.<\/li>\n<\/ul>\n<\/li>\n<li>Augsta pl\u016bsmas jauda:\n<ul>\n<li>These valves are designed to handle high flow rates, making them suitable for applications that demand substantial fluid flow.<\/li>\n<li>To optimiz\u0113t\u0101s iek\u0161\u0113j\u0101s ejas un iztur\u012bg\u0101 konstrukcija nodro\u0161ina minim\u0101lu spiediena kritumu un efekt\u012bvu \u0161\u0137idruma p\u0101rvald\u012bbu.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">WEH10 \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Switching pilot oil volume\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08AC and DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0\u00a0ms<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">60<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">55<\/td>\n<td align=\"left\" valign=\"middle\">15<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0\u00a0 ms<\/td>\n<td align=\"left\" valign=\"middle\">35<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">75<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">70<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0 \u00a0ms<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">40<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">20<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">HC\u3001HD\u3001HK\u3001HZ\u3001HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Svars<\/td>\n<td align=\"left\" valign=\"middle\">Single solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Double solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">7.1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Switching time regulator kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">1.0<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Reducing valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH16&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V)bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">3-position valve \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply ( apply to \u00a0C\u3001Z\u3001F\u3001 G\u3001<br \/>\nH\u3001P\u3001T\u3001V) bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 9.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">WEH25&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">95<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight\u00a0 \u00a0kg<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG32<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH32&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0 \u00a03-position valve \u00a0\u00a0 8.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a015<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range \u00a0\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">29.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">58.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">( DC \uff1a50\uff0cAC \uff1a60)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C\u3001D\u3001K\u3001Z\u3001YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"pro_d\">\n<div class=\"wrap\">\n<div class=\"content sidebar-content clearfix\">\n<div class=\"right-cont\">\n<div class=\"show-model-bobx\">\n<div class=\"bottom\">\n<div class=\"val-bar-box\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Advantages:<\/strong><\/h2>\n<p>\u2022 Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Wet DC or AC solenoid (optional)<br \/>\n\u2022 With manual emergency control<br \/>\n\u2022 Electropneumatic connection as single or center connection<br \/>\n\u2022 Spring or hydraulic alignment or bias<\/p>\n<h2><strong>Usage Method Of WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Sist\u0113mas integr\u0101cija:<\/strong>\n<ul>\n<li>Identify the optimal location for installing the WEH series valves within the hydraulic system, considering the desired flow path and control requirements.<\/li>\n<li>Nodro\u0161iniet sader\u012bbu ar sist\u0113mas spiediena un pl\u016bsmas specifik\u0101cij\u0101m.<\/li>\n<li>Dro\u0161i uzst\u0101diet v\u0101rstus, izmantojot atbilsto\u0161us kron\u0161teinus vai mont\u0101\u017eas piederumus.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pilot Control Setup:<\/strong>\n<ul>\n<li>Connect the pilot control lines to the designated ports on the valves, following the manufacturer&#8217;s instructions.<\/li>\n<li>Ensure proper sizing and routing of the pilot lines to maintain optimal control signal integrity.<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u0160\u0137idruma savienojumi:<\/strong>\n<ul>\n<li>Izv\u0113lieties sader\u012bgus hidrauliskos savienojumus un \u0161\u013c\u016btenes, lai nodro\u0161in\u0101tu dro\u0161us un herm\u0113tiskus savienojumus.<\/li>\n<li>Uzst\u0101d\u012b\u0161anas proces\u0101 iev\u0113rojiet ra\u017eot\u0101ja nor\u0101d\u012bjumus par pareizaj\u0101m griezes momenta v\u0113rt\u012bb\u0101m.<\/li>\n<li>Lai nodro\u0161in\u0101tu uzticamu bl\u012bv\u0113jumu, izmantojiet atbilsto\u0161us v\u012bt\u0146u herm\u0113ti\u0137us vai lenti.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Vad\u012bba un regul\u0113\u0161ana:<\/strong>\n<ul>\n<li>To operate the WEH series valves, utilize the recommended control method, such as manual levers or electrical controls.<\/li>\n<li>Adjust the valves&#8217; settings to achieve the desired flow direction and rates, ensuring optimal performance.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Do Hydraulic Valve Lifters Work?<\/strong><\/h2>\n<p>Hydraulic valve lifters, also known as hydraulic tappets or hydraulic lash adjusters, play a vital role in the proper operation of an internal combustion engine. They are responsible for maintaining the proper clearance, or &#8220;lash,&#8221; between the engine&#8217;s camshaft and valve train components. Here&#8217;s an overview of how hydraulic valve lifters work:<\/p>\n<ol>\n<li><strong>Strukt\u016bra:<\/strong>\n<ul>\n<li>Hydraulic valve lifters are small cylindrical devices typically made of metal.<\/li>\n<li>They are between the camshaft and the engine&#8217;s valve train components, such as the pushrods, rocker arms, or overhead cam followers.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Hydraulic Operation:<\/strong>\n<ul>\n<li>Inside the hydraulic valve lifter, a small piston mechanism operates based on hydraulic pressure.<\/li>\n<li>The lifter is filled with hydraulic fluid, typically engine oil, which acts as a working fluid.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Camshaft Interaction:<\/strong>\n<ul>\n<li>The camshaft has lobes or eccentric shapes that push against the lifters as it rotates.<\/li>\n<li>As the camshaft lobe comes into contact with the lifter, it applies a force that compresses its internal piston.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Adjustment:<\/strong>\n<ul>\n<li>When the lifter&#8217;s piston is compressed, it pushes the hydraulic fluid out of the lifter through a small orifice.<\/li>\n<li>This hydraulic fluid is expelled into the engine&#8217;s oil galleries or passages.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Compensation:<\/strong>\n<ul>\n<li>The expelled hydraulic fluid creates a hydraulic cushion or &#8220;spring&#8221; effect, compensating for any clearance or lash between the camshaft lobe and the valve train components.<\/li>\n<li>This compensation eliminates excessive clearance and ensures that the valve train remains in constant contact with the camshaft lobes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Maintenance of Lash:<\/strong>\n<ul>\n<li>If there is excessive clearance or lash in the valve train due to wear or other factors, the lifter&#8217;s internal piston will extend further to maintain the necessary hydraulic pressure.<\/li>\n<li>This extended position allows the lifter to take up the additional clearance, thus maintaining proper valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Oil Pressure and Lubrication:<\/strong>\n<ul>\n<li>The hydraulic valve lifters rely on the engine&#8217;s oil pressure for proper operation.<\/li>\n<li>The oil pump circulates oil through the engine, and the lifters receive a continuous oil supply to maintain hydraulic pressure and lubrication.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>R\u016bpn\u012bcas iesp\u0113jas un jauda:<\/strong><\/h2>\n<h3>(1) Mont\u0101\u017ea<\/h3>\n<p>Mums ir pirmklas\u012bga neatkar\u012bga p\u0113tniec\u012bbas un att\u012bst\u012bbas mont\u0101\u017eas platforma. Hidraulisko cilindru ra\u017eo\u0161anas darbn\u012bc\u0101 ir \u010detras pusautom\u0101tiskas pacel\u0161anas cilindru mont\u0101\u017eas l\u012bnijas un viena autom\u0101tisk\u0101 sl\u012bpuma cilindru mont\u0101\u017eas l\u012bnija ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 1 miljons vien\u012bbu. Speci\u0101lo cilindru darbn\u012bca ir apr\u012bkota ar da\u017e\u0101du specifik\u0101ciju pusautom\u0101tisku t\u012br\u012b\u0161anas mont\u0101\u017eas sist\u0113mu ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 200 000 vien\u012bbu un apr\u012bkota ar slaven\u0101m CNC apstr\u0101des iek\u0101rt\u0101m, apstr\u0101des centru, augstas precizit\u0101tes cilindru apstr\u0101des speci\u0101lo apr\u012bkojumu, robotiz\u0113tu metin\u0101\u0161anas iek\u0101rtu, autom\u0101tisku t\u012br\u012b\u0161anas iek\u0101rtu, autom\u0101tisku cilindru mont\u0101\u017eas iek\u0101rtu un autom\u0101tisku kr\u0101so\u0161anas ra\u017eo\u0161anas l\u012bniju. Eso\u0161ais kritiskais apr\u012bkojums ir vair\u0101k nek\u0101 300 komplektu (komplektu). Optim\u0101la iek\u0101rtu resursu sadale un efekt\u012bva izmanto\u0161ana nodro\u0161ina produktu precizit\u0101tes pras\u012bbas un apmierina produktu augst\u0101s kvalit\u0101tes pras\u012bbas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Apstr\u0101de<\/h3>\n<p>Apstr\u0101des cehs ir apr\u012bkots ar piel\u0101gotu sl\u012bpo slie\u017eu virpo\u0161anas centru, apstr\u0101des centru, \u0101trgaitas asin\u0101\u0161anas ma\u0161\u012bnu, metin\u0101\u0161anas robotu un citu saist\u012btu apr\u012bkojumu, kas var apstr\u0101d\u0101t cilindriskas caurules ar maksim\u0101lo iek\u0161\u0113jo diametru 400 mm un maksim\u0101lo garumu 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Metin\u0101\u0161ana<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Kr\u0101so\u0161ana un p\u0101rkl\u0101\u0161ana<\/h3>\n<p>Ar maz\u0101m un vid\u0113ja izm\u0113ra cilindrisk\u0101m autom\u0101tisk\u0101m \u016bdens b\u0101zes kr\u0101su p\u0101rkl\u0101\u0161anas l\u012bnij\u0101m, lai pan\u0101ktu autom\u0101tisku robotu iekrau\u0161anu un izkrau\u0161anu un autom\u0101tisku izsmidzin\u0101\u0161anu, projekt\u0113t\u0101 jauda ir 4000 gabali mai\u0146\u0101;<br \/>\nMums ir ar\u012b pusautom\u0101tiska kr\u0101su ra\u017eo\u0161anas l\u012bnija lieliem baloniem, ko darbina \u0137\u0113des piedzi\u0146a, ar 60 kastu konstrukcijas jaudu vien\u0101 mai\u0146\u0101.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test\u0113\u0161ana<\/h3>\n<p>Mums ir augst\u0101k\u0101s klases p\u0101rbaudes iek\u0101rtas un test\u0113\u0161anas stendi, lai nodro\u0161in\u0101tu, ka balona veiktsp\u0113ja atbilst pras\u012bb\u0101m.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>M\u0113s esam viens no lab\u0101kajiem hidraulisko cilindru ra\u017eot\u0101jiem. M\u0113s varam pied\u0101v\u0101t visaptvero\u0161us hidrauliskos cilindrus. M\u0113s nodro\u0161in\u0101m ar\u012b atbilsto\u0161us <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">lauksaimniec\u012bbas p\u0101rnesumk\u0101rbas<\/a>. M\u0113s esam eksport\u0113ju\u0161i savus produktus klientiem vis\u0101 pasaul\u0113 un esam ieguvu\u0161i labu reput\u0101ciju, pateicoties m\u016bsu izcilajai produktu kvalit\u0101tei un p\u0113cp\u0101rdo\u0161anas servisam. M\u0113s aicin\u0101m klientus no valsts un \u0101rvalst\u012bm sazin\u0101ties ar mums, lai risin\u0101tu biznesa sarunas, apmain\u012btos ar inform\u0101ciju un... <a href=\"https:\/\/www.hydraulic-cylinders.net\/lv\/contact-us\/\">sadarboties ar mums<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WEH Series Directional Hydraulic Valves Of Pilot Operated The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility. The WEH series directional hydraulic valves of pilot operated are [&hellip;]<\/p>","protected":false},"featured_media":2072,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2055","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product\/2055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/comments?post=2055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media\/2072"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media?parent=2055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_brand?post=2055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_cat?post=2055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_tag?post=2055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}