{"id":2079,"date":"2023-10-26T06:23:21","date_gmt":"2023-10-26T06:23:21","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2079"},"modified":"2023-10-26T06:23:22","modified_gmt":"2023-10-26T06:23:22","slug":"gweh-series-explosion-proof-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/lv\/products\/gweh-series-explosion-proof-directional-hydraulic-valve\/","title":{"rendered":"GWEH Series Explosion-proof Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>GWEH Series Explosion-proof Directional Hydraulic Valve <\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2095\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/gweh-series-explosion-proof-directional-hydraulic-valve-1-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The GWEH series explosion-proof directional hydraulic valve is an innovative solution designed to provide optimal safety and precise control in hydraulic systems operating in hazardous environments. With its explosion-proof features, reliable performance, and advanced functionalities, this valve offers enhanced safety measures, efficient fluid flow control, and compatibility with various industrial applications.<\/p>\n<p>The GWEH series explosion-proof directional hydraulic valve is a reliable and efficient solution for industries operating in hazardous environments. With its explosion-proof design, precise directional control, versatility, and high performance, this valve ensures safety and control in hydraulic systems. Following the recommended usage methods and adhering to regular maintenance practices, the GWEH series valve delivers safe and efficient operation in explosive atmospheres. Upgrade your hydraulic system with the GWEH series explosion-proof directional hydraulic valve and experience enhanced safety, optimal fluid flow control, and reliable performance.<\/p>\n<p>GWEH Series Explosion-proof Directional Hydraulic Valve Key Characteristics:<\/p>\n<ul>\n<li>Explosion-proof Design:\n<ul>\n<li>The GWEH series valve is engineered with a robust explosion-proof design, ensuring safe operation in environments containing flammable gases or dust.<\/li>\n<li>It complies with stringent safety standards and certifications, minimizing the risk of ignition and ensuring the safety of personnel and equipment.<\/li>\n<\/ul>\n<\/li>\n<li>Virziena vad\u012bba:\n<ul>\n<li>This hydraulic valve provides precise directional control of fluid flow, allowing for the activation and deactivation of specific hydraulic actuators.<\/li>\n<li>It enables smooth and reliable operation of various hydraulic functions, such as cylinder extension and retraction or motor direction changes.<\/li>\n<\/ul>\n<\/li>\n<li>Versatility and Compatibility:\n<ul>\n<li>The GWEH series valve is highly versatile and compatible with various hydraulic systems and applications.<\/li>\n<li>It can seamlessly integrate into industrial machinery, mobile equipment, and automation systems operating in hazardous environments.<\/li>\n<\/ul>\n<\/li>\n<li>Augsta veiktsp\u0113ja:\n<ul>\n<li>With its advanced design and high-quality construction, the GWEH series hydraulic valve delivers exceptional performance and reliability.<\/li>\n<li>It ensures consistent and precise control over fluid flow, contributing to efficient and optimized system operation.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>GWEH Series Explosion-proof Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/p>\n<p>(not apply to \u00a0C, Z, F, G, H, P, T, V)<\/td>\n<td colspan=\"1\" rowspan=\"3\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 7<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<br \/>\n( apply to \u00a0C, Z, F, G, H, P, T, V)<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">\u00a04.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u0160\u0137idruma temperat\u016bras diapazons<\/td>\n<td colspan=\"1\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viskozit\u0101tes diapazons<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">2,8 l\u012bdz 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Controlled quantity in commutating process<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">cm3<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04 2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kundze<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u00a02-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kundze<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">3-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kundze<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">2-position valve<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">kundze<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">25<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"center\" valign=\"middle\">20<\/td>\n<td rowspan=\"1\" align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shortest switching time<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">L\/min<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">HC, HD, HK, HZ and HY of hydraulic return shall be installed horizontally. The rest are arbitrary<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">G-..WEH16..\/6B2.. \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B \u00a0bar<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"6\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0With internal pilot oil drain is impossible<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0bar<\/p>\n<p>With internal pilot oil supply\u00a0 bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 14<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<br \/>\n( apply to \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0 bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm2 \/s 2<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-Spring-centering 3-position valve \u00a0\u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-2-position valve \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" rowspan=\"1\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily\u3002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shorter switching time \u00a0 L\/min<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Weight of the valve \u00a0kg<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">about 10.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Specifik\u0101cijas<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">G-H-&#8230;WEH25..\/6B2&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Working pressureP,A,B \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0With internal pilot oil drain is impossible<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Y osta<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0bar<\/p>\n<p>With internal pilot oil supply\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-centering 3-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a018<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0\u00a0\u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a018<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil supply<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as \u00a0C\u3001Z\u3001F\u3001G\u3001H\u3001P\u3001T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u0160\u0137idrums<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm2 \/s 2<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.8 \u00a0to \u00a0500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-Spring-centering 3-position valve \u00a0\u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">-2-position valve \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" rowspan=\"1\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily\u3002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Flow of shorter switching time \u00a0 L\/min<\/td>\n<td colspan=\"8\" rowspan=\"1\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\" align=\"left\" valign=\"middle\">Weight of the valve \u00a0kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 19<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>GWEH Series Explosion-proof Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Directional valve directional the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Two-position four-way or three-position four-way<br \/>\n\u2022 Installation face follows DIN 24340 A, ISO 4401, and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Nomainiet spoli, neizlai\u017eot e\u013c\u013cu<\/p>\n<h2><strong>Usage Method Of GWEH Series Explosion-proof Directional Hydraulic Valve <\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li>Hazardous Area Assessment:\n<ul>\n<li>Conduct a thorough assessment of the hazardous area to identify the specific explosion-proof requirements and classification.<\/li>\n<li>Determine the appropriate safety measures and precautions needed to comply with the regulations.<\/li>\n<\/ul>\n<\/li>\n<li>V\u0101rsta izv\u0113le:\n<ul>\n<li>Select the GWEH Series Valve with the suitable specifications, considering factors such as pressure ratings, flow capacity, and voltage requirements.<\/li>\n<li>Ensure compatibility with the hydraulic system and the specific hazardous environment.<\/li>\n<\/ul>\n<\/li>\n<li>Uzst\u0101d\u012b\u0161ana:\n<ul>\n<li>Follow the manufacturer&#8217;s instructions for proper installation of the GWEH Series Valve in the hydraulic system.<\/li>\n<li>Ensure secure mounting and proper electrical connections, adhering to the recommended torque values and wiring guidelines.<\/li>\n<\/ul>\n<\/li>\n<li>Control and Activation:\n<ul>\n<li>Utilize the recommended control method, such as electrical signals or remote activation, to operate the GWEH Series Valve.<\/li>\n<li>Connect the valve to a suitable power source and control system, following the provided wiring diagrams.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Does A Hydraulic Control Valve Work?<\/strong><\/h2>\n<p>A hydraulic control valve is a critical component in hydraulic systems that regulates the flow and direction of hydraulic fluid to control the operation of hydraulic actuators. It enables precise control over various hydraulic functions, such as extending or retracting cylinders, controlling motor speed and direction, or adjusting the flow rate of hydraulic fluid. Here&#8217;s an overview of how a hydraulic control valve works:<\/p>\n<ol>\n<li><strong>V\u0101rsta strukt\u016bra:<\/strong>\n<ul>\n<li>A hydraulic control valve typically consists of a valve body, spools or poppets, and various internal passages.<\/li>\n<li>The valve body contains inlet and outlet ports for fluid connection and chambers that direct the flow.<\/li>\n<li>The spools or poppets are movable elements within the valve body that control the flow paths and connect the appropriate ports.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Flow Control:<\/strong>\n<ul>\n<li>The hydraulic control valve regulates the flow of hydraulic fluid by opening and closing specific flow paths within the valve.<\/li>\n<li>The position of the spools or poppets determines which ports are connected and allows fluid to flow in the desired direction.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Virziena vad\u012bba:<\/strong>\n<ul>\n<li>Hydraulic control valves provide directional control by selectively connecting or blocking fluid flow to different hydraulic actuators.<\/li>\n<li>By adjusting the position of the spools or poppets, the valve determines which actuator receives fluid and in which direction it moves.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Actuation Methods:<\/strong>\n<ul>\n<li>Hydraulic control valves can be actuated using manual levers, mechanical linkages, solenoids, or pilot pressure control.<\/li>\n<li>Manual control valves are operated by moving the levers or handles to position the spools or poppets.<\/li>\n<li>Solenoid-controlled valves use electromagnetic coils to actuate the valve, allowing for remote or automated control.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Control Modes:<\/strong>\n<ul>\n<li>Hydraulic control valves offer different control modes, such as 2-way, 3-way, or 4-way control.<\/li>\n<li>A 2-way control valve controls flow in one direction, allowing or blocking fluid flow.<\/li>\n<li>A 3-way control valve has three ports and can control the flow between two ports while blocking the third.<\/li>\n<li>A 4-way control valve has four ports and can route fluid between two actuator ports while blocking the other two.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Spiediena kompens\u0101cija:<\/strong>\n<ul>\n<li>Some hydraulic control valves are equipped with pressure compensation features to maintain a consistent flow rate despite changes in system pressure.<\/li>\n<li>These valves adjust the flow passages based on pressure differentials, allowing for precise control regardless of varying operating conditions.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Feedback and Control Loops:<\/strong>\n<ul>\n<li>Advanced hydraulic control valves may incorporate feedback mechanisms, such as position or pressure sensors, to provide feedback to a control system.<\/li>\n<li>This feedback enables closed-loop control, where the system can monitor and adjust the valve&#8217;s position or flow based on desired setpoints or operating conditions.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>R\u016bpn\u012bcas iesp\u0113jas un jauda:<\/strong><\/h2>\n<h3>(1) Mont\u0101\u017ea<\/h3>\n<p>Mums ir pirmklas\u012bga neatkar\u012bga p\u0113tniec\u012bbas un att\u012bst\u012bbas mont\u0101\u017eas platforma. Hidraulisko cilindru ra\u017eo\u0161anas darbn\u012bc\u0101 ir \u010detras pusautom\u0101tiskas pacel\u0161anas cilindru mont\u0101\u017eas l\u012bnijas un viena autom\u0101tisk\u0101 sl\u012bpuma cilindru mont\u0101\u017eas l\u012bnija ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 1 miljons vien\u012bbu. Speci\u0101lo cilindru darbn\u012bca ir apr\u012bkota ar da\u017e\u0101du specifik\u0101ciju pusautom\u0101tisku t\u012br\u012b\u0161anas mont\u0101\u017eas sist\u0113mu ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 200 000 vien\u012bbu un apr\u012bkota ar slaven\u0101m CNC apstr\u0101des iek\u0101rt\u0101m, apstr\u0101des centru, augstas precizit\u0101tes cilindru apstr\u0101des speci\u0101lo apr\u012bkojumu, robotiz\u0113tu metin\u0101\u0161anas iek\u0101rtu, autom\u0101tisku t\u012br\u012b\u0161anas iek\u0101rtu, autom\u0101tisku cilindru mont\u0101\u017eas iek\u0101rtu un autom\u0101tisku kr\u0101so\u0161anas ra\u017eo\u0161anas l\u012bniju. Eso\u0161ais kritiskais apr\u012bkojums ir vair\u0101k nek\u0101 300 komplektu (komplektu). Optim\u0101la iek\u0101rtu resursu sadale un efekt\u012bva izmanto\u0161ana nodro\u0161ina produktu precizit\u0101tes pras\u012bbas un apmierina produktu augst\u0101s kvalit\u0101tes pras\u012bbas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Apstr\u0101de<\/h3>\n<p>Apstr\u0101des cehs ir apr\u012bkots ar piel\u0101gotu sl\u012bpo slie\u017eu virpo\u0161anas centru, apstr\u0101des centru, \u0101trgaitas asin\u0101\u0161anas ma\u0161\u012bnu, metin\u0101\u0161anas robotu un citu saist\u012btu apr\u012bkojumu, kas var apstr\u0101d\u0101t cilindriskas caurules ar maksim\u0101lo iek\u0161\u0113jo diametru 400 mm un maksim\u0101lo garumu 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Metin\u0101\u0161ana<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Kr\u0101so\u0161ana un p\u0101rkl\u0101\u0161ana<\/h3>\n<p>Ar maz\u0101m un vid\u0113ja izm\u0113ra cilindrisk\u0101m autom\u0101tisk\u0101m \u016bdens b\u0101zes kr\u0101su p\u0101rkl\u0101\u0161anas l\u012bnij\u0101m, lai pan\u0101ktu autom\u0101tisku robotu iekrau\u0161anu un izkrau\u0161anu un autom\u0101tisku izsmidzin\u0101\u0161anu, projekt\u0113t\u0101 jauda ir 4000 gabali mai\u0146\u0101;<br \/>\nMums ir ar\u012b pusautom\u0101tiska kr\u0101su ra\u017eo\u0161anas l\u012bnija lieliem baloniem, ko darbina \u0137\u0113des piedzi\u0146a, ar 60 kastu konstrukcijas jaudu vien\u0101 mai\u0146\u0101.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test\u0113\u0161ana<\/h3>\n<p>Mums ir augst\u0101k\u0101s klases p\u0101rbaudes iek\u0101rtas un test\u0113\u0161anas stendi, lai nodro\u0161in\u0101tu, ka balona veiktsp\u0113ja atbilst pras\u012bb\u0101m.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>M\u0113s esam viens no lab\u0101kajiem hidraulisko cilindru ra\u017eot\u0101jiem. M\u0113s varam pied\u0101v\u0101t visaptvero\u0161us hidrauliskos cilindrus. M\u0113s nodro\u0161in\u0101m ar\u012b atbilsto\u0161us <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">lauksaimniec\u012bbas p\u0101rnesumk\u0101rbas<\/a>. M\u0113s esam eksport\u0113ju\u0161i savus produktus klientiem vis\u0101 pasaul\u0113 un esam ieguvu\u0161i labu reput\u0101ciju, pateicoties m\u016bsu izcilajai produktu kvalit\u0101tei un p\u0113cp\u0101rdo\u0161anas servisam. M\u0113s aicin\u0101m klientus no valsts un \u0101rvalst\u012bm sazin\u0101ties ar mums, lai risin\u0101tu biznesa sarunas, apmain\u012btos ar inform\u0101ciju un... <a href=\"https:\/\/www.hydraulic-cylinders.net\/lv\/contact-us\/\">sadarboties ar mums<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>GWEH Series Explosion-proof Directional Hydraulic Valve The GWEH series explosion-proof directional hydraulic valve is an innovative solution designed to provide optimal safety and precise control in hydraulic systems operating in hazardous environments. With its explosion-proof features, reliable performance, and advanced functionalities, this valve offers enhanced safety measures, efficient fluid flow control, and compatibility with various [&hellip;]<\/p>","protected":false},"featured_media":2094,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2079","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product\/2079","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/comments?post=2079"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media\/2094"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media?parent=2079"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_brand?post=2079"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_cat?post=2079"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_tag?post=2079"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}