{"id":2183,"date":"2023-10-31T08:19:26","date_gmt":"2023-10-31T08:19:26","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2183"},"modified":"2023-10-31T08:19:31","modified_gmt":"2023-10-31T08:19:31","slug":"4wrae-series-direct-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/lv\/products\/4wrae-series-direct-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve <\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2200\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/4wrae-series-direct-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The 4WRA(E) series direct operated proportional directional hydraulic valve is a state-of-the-art hydraulic component designed to provide precise control and efficient operation in hydraulic systems. With its direct-operated proportional directional control technology, this valve offers accurate flow control, seamless direction changes, and optimized performance.<\/p>\n<p>The 4WRA(E) series direct operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and optimal energy efficiency. Its direct-operated proportional control technology ensures accurate and responsive operation, while the high flow capacity and energy-efficient design contribute to enhanced system performance. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRA(E) series valve, elevating your hydraulic system to new levels of precision and efficiency. Upgrade your hydraulic setup today and experience the power of the 4WRA(E) series direct operated proportional directional hydraulic valve.<\/p>\n<p>4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ul>\n<li>Direct Operated Proportional Control:\n<ul>\n<li>The 4WRA(E) series valve utilizes direct-operated proportional control, allowing for precise and immediate response to control signals.<\/li>\n<li>This feature ensures accurate flow control and seamless transitions between different hydraulic functions.<\/li>\n<\/ul>\n<\/li>\n<li>Augsta pl\u016bsmas jauda:\n<ul>\n<li>With its robust design, the valve offers high flow capacity, making it suitable for applications requiring substantial hydraulic power.<\/li>\n<li>It allows for efficient handling of large fluid volumes, contributing to enhanced system performance.<\/li>\n<\/ul>\n<\/li>\n<li>Versatile Directional Control:\n<ul>\n<li>The 4WRA(E) series valve provides versatile directional control, enabling smooth and precise changes in hydraulic fluid direction.<\/li>\n<li>It allows for the seamless activation of hydraulic components such as cylinders, motors, and actuators in different directions.<\/li>\n<\/ul>\n<\/li>\n<li>Energy Efficiency:\n<ul>\n<li>Designed with energy efficiency in mind, this valve minimizes pressure drops and optimizes flow control, resulting in reduced energy consumption.<\/li>\n<li>By efficiently managing hydraulic power, it helps maximize system performance while minimizing operational costs.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"9\" align=\"left\" valign=\"middle\"><strong>Hidraulisk\u0101<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161anas poz\u012bcija<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">optional, preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Izm\u0113rs<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">6<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">10<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Svars<\/td>\n<td align=\"left\" valign=\"middle\">4WRA&#8230;L2X<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Kg<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">6.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">4WRAE&#8230;L2X<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2.2<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">6.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow qnom\uff0cwhen \u0394p = 10 bar<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">7\u300115\u300126<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">30\u300160<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Hister\u0113ze<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u22645<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Atk\u0101rtojam\u012bba<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u22641<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Response sensitivity<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u22640.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Maks. darba spiediens<\/td>\n<td align=\"left\" valign=\"middle\">Port s A B P<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port \u00a0T<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">210<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0\u0160\u0137idrums<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Miner\u0101le\u013c\u013ca, kas piem\u0113rota NBR un FKM bl\u012bv\u0113jumiem<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Fosf\u0101ta esteris FKM bl\u012bv\u0113jumam<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0\u0160\u0137idruma temperat\u016bras diapazons<\/td>\n<td align=\"left\" valign=\"middle\">4WRA&#8230;L2X<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">-20\u2103 to 70\u2103\uff08-4\u00b0F to 158\u00b0F\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">4WRAE&#8230;L2X<\/td>\n<td colspan=\"1\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">-20\u2103\u00a0to\u00a050\u2103\uff08-4\u00b0 F\u00a0to\u00a0122\u00b0 F\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Viskozit\u0101tes diapazons<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0mm\u00b2\/s<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">20 to 380\uff08preferably 30 to 46\uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u00a0Pies\u0101r\u0146ojuma pak\u0101pe<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">NAS1638 class9 or ISO 4406 class 20\/18\/15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" align=\"left\" valign=\"middle\"><strong>Elektriskie dati<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" align=\"left\" valign=\"middle\"><strong>1)solenoid<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Voltage type<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value signal<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">\u00b110V or 4\uff5e20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. current per solenoid<\/td>\n<td align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">2.5<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">0.8<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Spoles pretest\u012bba<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0Cold value<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">19.5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u00a0Max. warm value<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">3<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">28.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Duty<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">ED100%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Coil temperature<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Valve protection to EN 60529<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" align=\"left\" valign=\"middle\"><strong>2)Control electronics<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Ampilfier<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4WRA&#8230;L2X<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">VT-VSPA2-L2X<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4WRAE&#8230;L2X<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Integrated in the valve(OBE)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Operating voltage<\/td>\n<td align=\"left\" valign=\"middle\">Nominal voltage<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">VDC<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">24<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Lower limiting value<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">21\/22(4WRA)\uff0c19(4WRAE)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Upper limiting value<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">35<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Amplifier current consumption<\/td>\n<td align=\"left\" valign=\"middle\">Imax<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">&lt;1.8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Imax<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"6\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Direct-acting proportional directional valve, used to control the flow and direction of liquid flow<br \/>\n\u2022 Panel type installation<br \/>\n\u2022 The proportional solenoid actuates the valve core through the threaded connection, and the coil can be removed separately<br \/>\n\u2022 Spool spring alignment alignment<br \/>\n\u2022 Optional with built-in amplifier, 4WRAE&#8230;L2X type input can be A1 or F1<br \/>\n\u2022 Supporting supply of external amplifier<\/p>\n<h2><strong>Usage Method Of 4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Sist\u0113mas nov\u0113rt\u0113\u0161ana:<\/strong>\n<ul>\n<li>Evaluate your hydraulic system and identify the specific flow control and directional requirements.<\/li>\n<li>Determine if the 4WRA(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<\/li>\n<li><strong>V\u0101rsta izv\u0113le:<\/strong>\n<ul>\n<li>Select the appropriate variant of the 4WRA(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>\u0145emiet v\u0113r\u0101 t\u0101dus faktorus k\u0101 maksim\u0101lais pl\u016bsmas \u0101trums, spiediena v\u0113rt\u0113jums, reakcijas laiks un ekspluat\u0101cijas apst\u0101k\u013ci.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Uzst\u0101d\u012b\u0161ana:<\/strong>\n<ul>\n<li>R\u016bp\u012bgi iev\u0113rojiet ra\u017eot\u0101ja uzst\u0101d\u012b\u0161anas instrukcijas, nodro\u0161inot pareizu izl\u012bdzin\u0101\u0161anu un dro\u0161u v\u0101rsta stiprin\u0101jumu.<\/li>\n<li>Pievienojiet v\u0101rstu hidrauliskajai sist\u0113mai, nodro\u0161inot savienojumus bez nopl\u016bd\u0113m un pareizu pl\u016bsmas virziena izl\u012bdzin\u0101\u0161anu.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Vad\u012bbas sign\u0101la savienojums:<\/strong>\n<ul>\n<li>Connect the control signal wires of the valve to the appropriate control device, such as a proportional amplifier or electronic control unit.<\/li>\n<li>Ensure proper wiring and compatibility between the valve and the control device to enable accurate and responsive control.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How To Adjust Valve Lash On Hydraulic Lifters?<\/strong><\/h2>\n<p>Adjusting valve lash on hydraulic lifters is a crucial maintenance task to ensure proper engine performance and prevent issues such as noisy valves or reduced power. Here&#8217;s a step-by-step guide on how to adjust valve lash on hydraulic lifters:<\/p>\n<ol>\n<li><strong>Sagatavo\u0161ana:<\/strong>\n<ul>\n<li>Ensure the engine is off and cool before starting the adjustment process.<\/li>\n<li>Familiarize yourself with the engine&#8217;s firing order and the specific valve lash specifications provided by the manufacturer for your engine model.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Identify the Correct Cylinder:<\/strong>\n<ul>\n<li>Locate the firing position of the engine by referring to the engine&#8217;s firing order diagram.<\/li>\n<li>Identify the cylinder that corresponds to the specific valve you want to adjust.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Novietojiet cilindru:<\/strong>\n<ul>\n<li>Rotate the engine crankshaft manually using a socket wrench or the engine&#8217;s built-in turning mechanism.<\/li>\n<li>Position the cylinder you want to adjust at the top dead center (TDC) on the compression stroke. You can do this by aligning the timing marks on the crankshaft pulley or using a piston stop tool.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Loosen the Rocker Arm:<\/strong>\n<ul>\n<li>Locate the rocker arm on the specific valve you want to adjust.<\/li>\n<li>Loosen the rocker arm nut or adjuster screw using an appropriate wrench or socket.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Adjust the Valve Lash:<\/strong>\n<ul>\n<li>With the rocker arm loose, you can now adjust the valve lash. The valve lash is the clearance between the rocker arm and the valve stem.<\/li>\n<li>Use a feeler gauge to measure the existing valve lash. Insert the appropriate thickness gauge between the rocker arm and the valve stem.<\/li>\n<li>If the clearance is too tight, meaning the feeler gauge does not fit or has excessive resistance, you need to increase the valve lash. If the clearance is too loose, meaning the feeler gauge slides in too easily, you need to decrease the valve lash.<\/li>\n<li>To adjust the valve lash, tighten or loosen the rocker arm nut or adjuster screw accordingly. Refer to the manufacturer&#8217;s specifications for the recommended amount of adjustment to be made.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Recheck the Valve Lash:<\/strong>\n<ul>\n<li>After making the adjustment, recheck the valve lash using the feeler gauge to ensure it falls within the recommended specifications.<\/li>\n<li>Repeat the adjustment process if necessary until the correct valve lash is achieved.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Repeat for Other Cylinders:<\/strong>\n<ul>\n<li>Proceed to the next cylinder in the firing order and repeat steps 4 to 6 for each cylinder you want to adjust.<\/li>\n<li>Remember to rotate the crankshaft and position each cylinder at TDC on the compression stroke before adjusting its valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Secure the Rocker Arm:<\/strong>\n<ul>\n<li>Once the valve lash is properly adjusted for each cylinder, tighten the rocker arm nut or adjuster screw to the manufacturer&#8217;s recommended torque specification.<\/li>\n<li>Double-check that the valve lash remains within the specified range after tightening.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Nosl\u0113guma p\u0101rbaudes:<\/strong>\n<ul>\n<li>Rotate the engine crankshaft a few times to ensure smooth rotation and check for any unusual noises or resistance.<\/li>\n<li>Start the engine and listen for any abnormal valve noises. If you hear excessive tapping or knocking, recheck the valve lash adjustment.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>R\u016bpn\u012bcas iesp\u0113jas un jauda:<\/strong><\/h2>\n<h3>(1) Mont\u0101\u017ea<\/h3>\n<p>Mums ir pirmklas\u012bga neatkar\u012bga p\u0113tniec\u012bbas un att\u012bst\u012bbas mont\u0101\u017eas platforma. Hidraulisko cilindru ra\u017eo\u0161anas darbn\u012bc\u0101 ir \u010detras pusautom\u0101tiskas pacel\u0161anas cilindru mont\u0101\u017eas l\u012bnijas un viena autom\u0101tisk\u0101 sl\u012bpuma cilindru mont\u0101\u017eas l\u012bnija ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 1 miljons vien\u012bbu. Speci\u0101lo cilindru darbn\u012bca ir apr\u012bkota ar da\u017e\u0101du specifik\u0101ciju pusautom\u0101tisku t\u012br\u012b\u0161anas mont\u0101\u017eas sist\u0113mu ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 200 000 vien\u012bbu un apr\u012bkota ar slaven\u0101m CNC apstr\u0101des iek\u0101rt\u0101m, apstr\u0101des centru, augstas precizit\u0101tes cilindru apstr\u0101des speci\u0101lo apr\u012bkojumu, robotiz\u0113tu metin\u0101\u0161anas iek\u0101rtu, autom\u0101tisku t\u012br\u012b\u0161anas iek\u0101rtu, autom\u0101tisku cilindru mont\u0101\u017eas iek\u0101rtu un autom\u0101tisku kr\u0101so\u0161anas ra\u017eo\u0161anas l\u012bniju. Eso\u0161ais kritiskais apr\u012bkojums ir vair\u0101k nek\u0101 300 komplektu (komplektu). Optim\u0101la iek\u0101rtu resursu sadale un efekt\u012bva izmanto\u0161ana nodro\u0161ina produktu precizit\u0101tes pras\u012bbas un apmierina produktu augst\u0101s kvalit\u0101tes pras\u012bbas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Apstr\u0101de<\/h3>\n<p>Apstr\u0101des cehs ir apr\u012bkots ar piel\u0101gotu sl\u012bpo slie\u017eu virpo\u0161anas centru, apstr\u0101des centru, \u0101trgaitas asin\u0101\u0161anas ma\u0161\u012bnu, metin\u0101\u0161anas robotu un citu saist\u012btu apr\u012bkojumu, kas var apstr\u0101d\u0101t cilindriskas caurules ar maksim\u0101lo iek\u0161\u0113jo diametru 400 mm un maksim\u0101lo garumu 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Metin\u0101\u0161ana<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Kr\u0101so\u0161ana un p\u0101rkl\u0101\u0161ana<\/h3>\n<p>Ar maz\u0101m un vid\u0113ja izm\u0113ra cilindrisk\u0101m autom\u0101tisk\u0101m \u016bdens b\u0101zes kr\u0101su p\u0101rkl\u0101\u0161anas l\u012bnij\u0101m, lai pan\u0101ktu autom\u0101tisku robotu iekrau\u0161anu un izkrau\u0161anu un autom\u0101tisku izsmidzin\u0101\u0161anu, projekt\u0113t\u0101 jauda ir 4000 gabali mai\u0146\u0101;<br \/>\nMums ir ar\u012b pusautom\u0101tiska kr\u0101su ra\u017eo\u0161anas l\u012bnija lieliem baloniem, ko darbina \u0137\u0113des piedzi\u0146a, ar 60 kastu konstrukcijas jaudu vien\u0101 mai\u0146\u0101.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test\u0113\u0161ana<\/h3>\n<p>Mums ir augst\u0101k\u0101s klases p\u0101rbaudes iek\u0101rtas un test\u0113\u0161anas stendi, lai nodro\u0161in\u0101tu, ka balona veiktsp\u0113ja atbilst pras\u012bb\u0101m.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>M\u0113s esam viens no lab\u0101kajiem hidraulisko cilindru ra\u017eot\u0101jiem. M\u0113s varam pied\u0101v\u0101t visaptvero\u0161us hidrauliskos cilindrus. M\u0113s nodro\u0161in\u0101m ar\u012b atbilsto\u0161us <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">lauksaimniec\u012bbas p\u0101rnesumk\u0101rbas<\/a>. M\u0113s esam eksport\u0113ju\u0161i savus produktus klientiem vis\u0101 pasaul\u0113 un esam ieguvu\u0161i labu reput\u0101ciju, pateicoties m\u016bsu izcilajai produktu kvalit\u0101tei un p\u0113cp\u0101rdo\u0161anas servisam. M\u0113s aicin\u0101m klientus no valsts un \u0101rvalst\u012bm sazin\u0101ties ar mums, lai risin\u0101tu biznesa sarunas, apmain\u012btos ar inform\u0101ciju un... <a href=\"https:\/\/www.hydraulic-cylinders.net\/lv\/contact-us\/\">sadarboties ar mums<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRA(E) Series Direct operated Proportional Directional Hydraulic Valve The 4WRA(E) series direct operated proportional directional hydraulic valve is a state-of-the-art hydraulic component designed to provide precise control and efficient operation in hydraulic systems. With its direct-operated proportional directional control technology, this valve offers accurate flow control, seamless direction changes, and optimized performance. The 4WRA(E) series [&hellip;]<\/p>","protected":false},"featured_media":2201,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2183","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product\/2183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/comments?post=2183"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media\/2201"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media?parent=2183"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_brand?post=2183"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_cat?post=2183"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_tag?post=2183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}