{"id":2205,"date":"2023-11-01T03:32:55","date_gmt":"2023-11-01T03:32:55","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2205"},"modified":"2023-11-01T03:53:47","modified_gmt":"2023-11-01T03:53:47","slug":"4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/lv\/products\/4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2213\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrzhe-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRZ\/H(E) series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilot-Operated Proportional Control<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>\u0160\u012b funkcija nodro\u0161ina prec\u012bzu un atsauc\u012bgu vad\u012bbu, k\u0101 rezult\u0101t\u0101 uzlabojas sist\u0113mas veiktsp\u0113ja, samazin\u0101s ener\u0123ijas pat\u0113ri\u0146\u0161 un palielin\u0101s produktivit\u0101te.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Versatile Directional Control<\/li>\n<\/ol>\n<ul>\n<li>\u0160is v\u0101rsts pied\u0101v\u0101 daudzpus\u012bgu hidraulisk\u0101 \u0161\u0137idruma virziena kontroli, padarot to piem\u0113rotu pla\u0161am pielietojumu kl\u0101stam.<\/li>\n<li>Tas nodro\u0161ina neman\u0101mu hidraulisko komponentu, piem\u0113ram, cilindru, motoru un izpildmeh\u0101nismu, aktiviz\u0113\u0161anu un deaktiviz\u0113\u0161anu da\u017e\u0101dos virzienos, uzlabojot sist\u0113mas elast\u012bbu un piel\u0101gojam\u012bbu.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>High Flow Capacity<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>T\u0101 iztur\u012bg\u0101 konstrukcija nodro\u0161ina uzticamu darb\u012bbu pat sare\u017e\u0123\u012btos apst\u0101k\u013cos, nodro\u0161inot vienm\u0113r\u012bgu un efekt\u012bvu pl\u016bsmas kontroli.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Energoefektivit\u0101te<\/li>\n<\/ol>\n<ul>\n<li>By incorporating pilot-operated proportional control, this valve minimizes pressure drops and optimizes energy usage.<\/li>\n<li>It helps reduce energy consumption, resulting in cost savings and environmental benefits.<\/li>\n<\/ul>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>GeneraL<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Uzst\u0101d\u012b\u0161ana<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Optional,preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Storage temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 to +80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Apk\u0101rt\u0113j\u0101s vides temperat\u016bras diapazons<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 l\u012bdz +70<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 to +50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Svars<\/td>\n<td align=\"left\" valign=\"middle\">NS 10<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 16<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.4<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 25<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.4<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 32<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.4<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hidraulisk\u0101\u00a0<\/strong>\u00a0\u00a0 (measured with HLPAG.p=100bar : 40 \u2103 \u00b1 5 \u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Izm\u0113rs<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Darba spiediens<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td align=\"left\" valign=\"middle\">External pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">30 to 100 bar<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Internal pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100 to 350 with &#8220;D3&#8221; only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Main valve<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Return pressure<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (Port R) (external pilot oil drain))<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (internal pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Y osta<\/td>\n<td align=\"left\" valign=\"middle\">b\u0101rs<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pilot oil volume input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">cm<sup>3<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">1.7<\/td>\n<td align=\"left\" valign=\"middle\">4.6<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">26.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Pilot oil flow in port X and Y with a stepped input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">3.5<\/td>\n<td align=\"left\" valign=\"middle\">5.5<\/td>\n<td align=\"left\" valign=\"middle\">7<\/td>\n<td align=\"left\" valign=\"middle\">15.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of the main valve<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\">to 170<\/td>\n<td align=\"left\" valign=\"middle\">to 460<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0 to 870<\/td>\n<td align=\"left\" valign=\"middle\">to 1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP) to DIN 51524 Further fluids on enquiry<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 \u00a0to +80(preferably +40 to +50)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viskozit\u0101tes diapazons<\/td>\n<td align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">20 \u00a0to 380(preferably 30 to 46)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">Pies\u0101r\u0146ojuma pak\u0101pe<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 or ISO 4406(c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x \u2265 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 7<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Main valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 9<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hister\u0113ze<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u22646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electrical<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Type of protection of the valve to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65 with cable socket mounted and locked<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Voltage type<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">L\u012bdzstr\u0101va<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value overlap<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. current<\/td>\n<td align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Solenoid coil resisance<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Cold value at 20\u2103<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. warm value<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Cyclic duration factor<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Coil temperature<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve protection to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Control electronics<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">External amplifier for type WRZ<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">VT- VSPA2-L2X\/&#8230;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Command value signal<\/td>\n<td align=\"left\" valign=\"middle\">-Voltage input &#8220;A1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00b110<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">&#8211;Current input &#8220;F1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">mA<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">4 to 20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve, used to control the size and direction of the liquid flow<br \/>\n\u2022 Threaded connection type proportional solenoid, the coil can be disassembled separately<br \/>\n\u2022 Sub-plate mounting connection structure, connection size conforms to DIN2430 and ISO4401 standards<br \/>\n\u2022 Spool spring alignment alignment<br \/>\n\u2022 WRZE type with integrated proportional amplifierr<br \/>\n\u2022 WRZ type external amplifier (order separately)<\/p>\n<h2><strong>Usage Method Of 4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>System Evaluation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Nov\u0113rt\u0113jiet savu hidraulisko sist\u0113mu un nosakiet \u012bpa\u0161\u0101s pl\u016bsmas un virziena vad\u012bbas pras\u012bbas.<\/li>\n<li>Determine if the 4WRZ\/H(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Valve Selection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRZ\/H(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>\u0145emiet v\u0113r\u0101 t\u0101dus faktorus k\u0101 maksim\u0101lais pl\u016bsmas \u0101trums, spiediena v\u0113rt\u0113jums, reakcijas laiks un ekspluat\u0101cijas apst\u0101k\u013ci.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Uzst\u0101d\u012b\u0161ana<\/strong><\/li>\n<\/ol>\n<ul>\n<li>R\u016bp\u012bgi iev\u0113rojiet ra\u017eot\u0101ja uzst\u0101d\u012b\u0161anas instrukcijas, nodro\u0161inot pareizu v\u0101rsta izl\u012bdzin\u0101\u0161anu un dro\u0161u stiprin\u0101jumu.<\/li>\n<li>Make leak-free connections and ensure the correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Control Signal Connection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Pievienojiet v\u0101rsta vad\u012bbas sign\u0101la vadus piem\u0113rotai vad\u012bbas ier\u012bcei, piem\u0113ram, proporcion\u0101lajam pastiprin\u0101t\u0101jam vai elektroniskajam vad\u012bbas blokam.<\/li>\n<li>Lai vad\u012bba b\u016btu prec\u012bza un atsauc\u012bga, nodro\u0161iniet pareizu elektroinstal\u0101ciju un sader\u012bbu starp v\u0101rstu un vad\u012bbas ier\u012bci.<\/li>\n<\/ul>\n<h2><strong>How To Bleed Hydraulic Control Valve?<\/strong><\/h2>\n<p>Bleeding a hydraulic control valve is an essential maintenance procedure to remove any trapped air or gas from the system, ensuring optimal performance and efficiency. Here&#8217;s a step-by-step guide on how to bleed a hydraulic control valve:<\/p>\n<ol>\n<li><strong>Sagatavojiet sist\u0113mu:<\/strong>\n<ul>\n<li>Ensure that the hydraulic system is turned off and that the pressure is relieved. This step is crucial for your safety and to prevent any accidental movement or release of high-pressure fluids.<\/li>\n<li>Locate the bleeder valve or bleed screw on the hydraulic control valve. It is typically located on the top or side of the valve body and may have a protective cap or cover.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Positioning and Safety Measures:<\/strong>\n<ul>\n<li>Place a suitable container or absorbent material beneath the bleed valve to catch any fluid that may be expelled during the bleeding process.<\/li>\n<li>Wear appropriate personal protective equipment (PPE), such as safety goggles and gloves, to protect yourself from hydraulic fluid splashes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Opening the Bleed Valve:<\/strong>\n<ul>\n<li>Using an appropriate wrench or tool, carefully loosen the bleed valve or screw counterclockwise. Be cautious not to fully remove it at this stage.<\/li>\n<li>The bleed valve may have an O-ring or sealing washer. Take note of its position and ensure it is in good condition.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Activation:<\/strong>\n<ul>\n<li>Activate the hydraulic system by turning on the power source, such as an engine or hydraulic pump.<\/li>\n<li>Operate the control mechanism associated with the hydraulic control valve, such as a joystick or lever, to allow fluid flow through the valve.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bleeding Process:<\/strong>\n<ul>\n<li>Slowly open the bleed valve by turning it counterclockwise until you start to see hydraulic fluid or air bubbles escaping from the valve.<\/li>\n<li>Allow the fluid to flow for a few seconds or until you observe a steady stream of fluid without any air bubbles. This indicates that the air has been purged from the system.<\/li>\n<li>Be cautious not to open the bleed valve too much, as it may lead to excessive fluid loss or system damage.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Closing the Bleed Valve:<\/strong>\n<ul>\n<li>Once you have successfully bled the system, close the bleed valve by turning it clockwise. Ensure it is tightened securely but avoid over-tightening.<\/li>\n<li>Check for any leaks around the bleed valve or other connections. If you notice any leaks, address them promptly to prevent further issues.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Sist\u0113mas p\u0101rbaude:<\/strong>\n<ul>\n<li>Turn off the hydraulic system and inspect the fluid level in the reservoir. Add hydraulic fluid as necessary to maintain the recommended level.<\/li>\n<li>Test the operation of the hydraulic control valve and associated components to ensure proper functionality.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>R\u016bpn\u012bcas iesp\u0113jas un jauda:<\/strong><\/h2>\n<h3>(1) Mont\u0101\u017ea<\/h3>\n<p>Mums ir pirmklas\u012bga neatkar\u012bga p\u0113tniec\u012bbas un att\u012bst\u012bbas mont\u0101\u017eas platforma. Hidraulisko cilindru ra\u017eo\u0161anas darbn\u012bc\u0101 ir \u010detras pusautom\u0101tiskas pacel\u0161anas cilindru mont\u0101\u017eas l\u012bnijas un viena autom\u0101tisk\u0101 sl\u012bpuma cilindru mont\u0101\u017eas l\u012bnija ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 1 miljons vien\u012bbu. Speci\u0101lo cilindru darbn\u012bca ir apr\u012bkota ar da\u017e\u0101du specifik\u0101ciju pusautom\u0101tisku t\u012br\u012b\u0161anas mont\u0101\u017eas sist\u0113mu ar projekt\u0113to gada ra\u017eo\u0161anas jaudu 200 000 vien\u012bbu un apr\u012bkota ar slaven\u0101m CNC apstr\u0101des iek\u0101rt\u0101m, apstr\u0101des centru, augstas precizit\u0101tes cilindru apstr\u0101des speci\u0101lo apr\u012bkojumu, robotiz\u0113tu metin\u0101\u0161anas iek\u0101rtu, autom\u0101tisku t\u012br\u012b\u0161anas iek\u0101rtu, autom\u0101tisku cilindru mont\u0101\u017eas iek\u0101rtu un autom\u0101tisku kr\u0101so\u0161anas ra\u017eo\u0161anas l\u012bniju. Eso\u0161ais kritiskais apr\u012bkojums ir vair\u0101k nek\u0101 300 komplektu (komplektu). Optim\u0101la iek\u0101rtu resursu sadale un efekt\u012bva izmanto\u0161ana nodro\u0161ina produktu precizit\u0101tes pras\u012bbas un apmierina produktu augst\u0101s kvalit\u0101tes pras\u012bbas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Apstr\u0101de<\/h3>\n<p>Apstr\u0101des cehs ir apr\u012bkots ar piel\u0101gotu sl\u012bpo slie\u017eu virpo\u0161anas centru, apstr\u0101des centru, \u0101trgaitas asin\u0101\u0161anas ma\u0161\u012bnu, metin\u0101\u0161anas robotu un citu saist\u012btu apr\u012bkojumu, kas var apstr\u0101d\u0101t cilindriskas caurules ar maksim\u0101lo iek\u0161\u0113jo diametru 400 mm un maksim\u0101lo garumu 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Metin\u0101\u0161ana<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Kr\u0101so\u0161ana un p\u0101rkl\u0101\u0161ana<\/h3>\n<p>Ar maz\u0101m un vid\u0113ja izm\u0113ra cilindrisk\u0101m autom\u0101tisk\u0101m \u016bdens b\u0101zes kr\u0101su p\u0101rkl\u0101\u0161anas l\u012bnij\u0101m, lai pan\u0101ktu autom\u0101tisku robotu iekrau\u0161anu un izkrau\u0161anu un autom\u0101tisku izsmidzin\u0101\u0161anu, projekt\u0113t\u0101 jauda ir 4000 gabali mai\u0146\u0101;<br \/>\nMums ir ar\u012b pusautom\u0101tiska kr\u0101su ra\u017eo\u0161anas l\u012bnija lieliem baloniem, ko darbina \u0137\u0113des piedzi\u0146a, ar 60 kastu konstrukcijas jaudu vien\u0101 mai\u0146\u0101.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test\u0113\u0161ana<\/h3>\n<p>Mums ir augst\u0101k\u0101s klases p\u0101rbaudes iek\u0101rtas un test\u0113\u0161anas stendi, lai nodro\u0161in\u0101tu, ka balona veiktsp\u0113ja atbilst pras\u012bb\u0101m.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>M\u0113s esam viens no lab\u0101kajiem hidraulisko cilindru ra\u017eot\u0101jiem. M\u0113s varam pied\u0101v\u0101t visaptvero\u0161us hidrauliskos cilindrus. M\u0113s nodro\u0161in\u0101m ar\u012b atbilsto\u0161us <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">lauksaimniec\u012bbas p\u0101rnesumk\u0101rbas<\/a>. M\u0113s esam eksport\u0113ju\u0161i savus produktus klientiem vis\u0101 pasaul\u0113 un esam ieguvu\u0161i labu reput\u0101ciju, pateicoties m\u016bsu izcilajai produktu kvalit\u0101tei un p\u0113cp\u0101rdo\u0161anas servisam. M\u0113s aicin\u0101m klientus no valsts un \u0101rvalst\u012bm sazin\u0101ties ar mums, lai risin\u0101tu biznesa sarunas, apmain\u012btos ar inform\u0101ciju un... <a href=\"https:\/\/www.hydraulic-cylinders.net\/lv\/contact-us\/\">sadarboties ar mums<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2214,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product\/2205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/comments?post=2205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media\/2214"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/media?parent=2205"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_brand?post=2205"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_cat?post=2205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/lv\/wp-json\/wp\/v2\/product_tag?post=2205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}