{"id":2055,"date":"2023-10-25T08:13:01","date_gmt":"2023-10-25T08:13:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2055"},"modified":"2023-10-25T08:13:02","modified_gmt":"2023-10-25T08:13:02","slug":"weh-series-directional-hydraulic-valves-of-pilot-operated","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/pl\/produkt\/weh-series-directional-hydraulic-valves-of-pilot-operated\/","title":{"rendered":"Zawory hydrauliczne kierunkowe serii WEH sterowane pilotem"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>Zawory hydrauliczne kierunkowe serii WEH sterowane pilotem<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2071\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/weh-series-directional-hydraulic-valves-of-pilot-operated-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility.<\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are reliable, high-performance components that empower operators with precise control and efficient fluid management in hydraulic systems. With their pilot-operated design, exceptional directional control, a wide range of configurations, and high flow capacity, these valves offer the reliability and versatility required in various industries. Following the recommended usage methods and adhering to regular maintenance practices, the WEH series valves will continue delivering\u00a0exceptional performance. Upgrade your hydraulic system with the WEH series directional hydraulic valves operated and experience the benefits of precision, control, and reliability.<\/p>\n<p>WEH Series Directional Hydraulic Valves Of Pilot Operated Key Characteristics:<\/p>\n<ul>\n<li>Projekt pilota\u017cowy:\n<ul>\n<li>The WEH series valves utilize a pilot-operated design, which enhances their responsiveness and control accuracy.<\/li>\n<li>This design enables the valves to handle high-pressure applications, ensuring optimal performance easily.<\/li>\n<\/ul>\n<\/li>\n<li>Kontrola kierunkowa:\n<ul>\n<li>These hydraulic valves excel in providing precise directional control of hydraulic fluid.<\/li>\n<li>Operators can easily manage fluid flow and direct it to different actuators or components within the hydraulic system.<\/li>\n<\/ul>\n<\/li>\n<li>Wide Range of Configurations:\n<ul>\n<li>The WEH series valves are available in various configurations, including various sizes, flow rates, and pressure ratings.<\/li>\n<li>This versatility allows them to be tailored to specific application requirements and system specifications.<\/li>\n<\/ul>\n<\/li>\n<li>Wysoka przepustowo\u015b\u0107:\n<ul>\n<li>These valves are designed to handle high flow rates, making them suitable for applications that demand substantial fluid flow.<\/li>\n<li>Their optimized internal passages and robust construction ensure minimal pressure drop and efficient fluid management.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specyfikacje<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">WEH10 \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Port T<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Switching pilot oil volume\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08AC and DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0\u00a0ms<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">60<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">55<\/td>\n<td align=\"left\" valign=\"middle\">15<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0\u00a0 ms<\/td>\n<td align=\"left\" valign=\"middle\">35<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">75<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">70<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0 \u00a0ms<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">40<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">20<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">HC\u3001HD\u3001HK\u3001HZ\u3001HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Waga<\/td>\n<td align=\"left\" valign=\"middle\">Single solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Double solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">7.1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Switching time regulator kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">1.0<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Reducing valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specyfikacje<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH16&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V)bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">3-position valve \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply ( apply to \u00a0C\u3001Z\u3001F\u3001 G\u3001<br \/>\nH\u3001P\u3001T\u3001V) bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 9.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specyfikacje<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">WEH25&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Port T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">95<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight\u00a0 \u00a0kg<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG32<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specyfikacje<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH32&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Port T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Port Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0 \u00a03-position valve \u00a0\u00a0 8.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a015<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range \u00a0\u00a0mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">29.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">58.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">( DC \uff1a50\uff0cAC \uff1a60)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C\u3001D\u3001K\u3001Z\u3001YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"pro_d\">\n<div class=\"wrap\">\n<div class=\"content sidebar-content clearfix\">\n<div class=\"right-cont\">\n<div class=\"show-model-bobx\">\n<div class=\"bottom\">\n<div class=\"val-bar-box\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Advantages:<\/strong><\/h2>\n<p>\u2022 Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Wet DC or AC solenoid (optional)<br \/>\n\u2022 Z r\u0119cznym sterowaniem awaryjnym<br \/>\n\u2022 Electropneumatic connection as single or center connection<br \/>\n\u2022 Spring or hydraulic alignment or bias<\/p>\n<h2><strong>Usage Method Of WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Integracja system\u00f3w:<\/strong>\n<ul>\n<li>Identify the optimal location for installing the WEH series valves within the hydraulic system, considering the desired flow path and control requirements.<\/li>\n<li>Zapewnij zgodno\u015b\u0107 ze specyfikacjami ci\u015bnienia i przep\u0142ywu w systemie.<\/li>\n<li>Zamontuj zawory w spos\u00f3b bezpieczny, u\u017cywaj\u0105c odpowiednich wspornik\u00f3w lub akcesori\u00f3w monta\u017cowych.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pilot Control Setup:<\/strong>\n<ul>\n<li>Connect the pilot control lines to the designated ports on the valves, following the manufacturer&#8217;s instructions.<\/li>\n<li>Ensure proper sizing and routing of the pilot lines to maintain optimal control signal integrity.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Po\u0142\u0105czenia p\u0142ynne:<\/strong>\n<ul>\n<li>Wybierz kompatybilne z\u0142\u0105czki hydrauliczne i w\u0119\u017ce, aby zapewni\u0107 bezpieczne i szczelne po\u0142\u0105czenia.<\/li>\n<li>Podczas instalacji nale\u017cy przestrzega\u0107 instrukcji producenta dotycz\u0105cych w\u0142a\u015bciwych warto\u015bci momentu obrotowego.<\/li>\n<li>Aby zapewni\u0107 niezawodne uszczelnienie, nale\u017cy stosowa\u0107 odpowiednie uszczelniacze gwint\u00f3w lub ta\u015bm\u0119.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Kontrola i regulacja:<\/strong>\n<ul>\n<li>To operate the WEH series valves, utilize the recommended control method, such as manual levers or electrical controls.<\/li>\n<li>Dostosuj ustawienia zawor\u00f3w, aby uzyska\u0107 po\u017c\u0105dany kierunek i nat\u0119\u017cenie przep\u0142ywu, gwarantuj\u0105c optymaln\u0105 wydajno\u015b\u0107.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Do Hydraulic Valve Lifters Work?<\/strong><\/h2>\n<p>Hydraulic valve lifters, also known as hydraulic tappets or hydraulic lash adjusters, play a vital role in the proper operation of an internal combustion engine. They are responsible for maintaining the proper clearance, or &#8220;lash,&#8221; between the engine&#8217;s camshaft and valve train components. Here&#8217;s an overview of how hydraulic valve lifters work:<\/p>\n<ol>\n<li><strong>Structure:<\/strong>\n<ul>\n<li>Hydraulic valve lifters are small cylindrical devices typically made of metal.<\/li>\n<li>They are between the camshaft and the engine&#8217;s valve train components, such as the pushrods, rocker arms, or overhead cam followers.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Hydraulic Operation:<\/strong>\n<ul>\n<li>Inside the hydraulic valve lifter, a small piston mechanism operates based on hydraulic pressure.<\/li>\n<li>The lifter is filled with hydraulic fluid, typically engine oil, which acts as a working fluid.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Camshaft Interaction:<\/strong>\n<ul>\n<li>The camshaft has lobes or eccentric shapes that push against the lifters as it rotates.<\/li>\n<li>As the camshaft lobe comes into contact with the lifter, it applies a force that compresses its internal piston.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Adjustment:<\/strong>\n<ul>\n<li>When the lifter&#8217;s piston is compressed, it pushes the hydraulic fluid out of the lifter through a small orifice.<\/li>\n<li>This hydraulic fluid is expelled into the engine&#8217;s oil galleries or passages.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Compensation:<\/strong>\n<ul>\n<li>The expelled hydraulic fluid creates a hydraulic cushion or &#8220;spring&#8221; effect, compensating for any clearance or lash between the camshaft lobe and the valve train components.<\/li>\n<li>This compensation eliminates excessive clearance and ensures that the valve train remains in constant contact with the camshaft lobes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Maintenance of Lash:<\/strong>\n<ul>\n<li>If there is excessive clearance or lash in the valve train due to wear or other factors, the lifter&#8217;s internal piston will extend further to maintain the necessary hydraulic pressure.<\/li>\n<li>This extended position allows the lifter to take up the additional clearance, thus maintaining proper valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Oil Pressure and Lubrication:<\/strong>\n<ul>\n<li>The hydraulic valve lifters rely on the engine&#8217;s oil pressure for proper operation.<\/li>\n<li>The oil pump circulates oil through the engine, and the lifters receive a continuous oil supply to maintain hydraulic pressure and lubrication.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Mo\u017cliwo\u015bci i pojemno\u015b\u0107 fabryki:<\/strong><\/h2>\n<h3>(1) Monta\u017c<\/h3>\n<p>Dysponujemy najwy\u017cszej klasy niezale\u017cn\u0105 platform\u0105 badawczo-rozwojow\u0105. Warsztat produkcji si\u0142ownik\u00f3w hydraulicznych posiada cztery p\u00f3\u0142automatyczne linie monta\u017cowe si\u0142ownik\u00f3w podnosz\u0105cych i jedn\u0105 automatyczn\u0105 lini\u0119 monta\u017cow\u0105 si\u0142ownik\u00f3w przechy\u0142u, o projektowanej rocznej zdolno\u015bci produkcyjnej 1 miliona sztuk. Specjalny warsztat cylindr\u00f3w jest wyposa\u017cony w r\u00f3\u017cne specyfikacje p\u00f3\u0142automatycznego systemu monta\u017cu czyszcz\u0105cego o projektowanej rocznej zdolno\u015bci produkcyjnej 200 000 i wyposa\u017cony w s\u0142ynny sprz\u0119t do obr\u00f3bki CNC, centrum obr\u00f3bcze, specjalny sprz\u0119t do precyzyjnej obr\u00f3bki cylindr\u00f3w, robot spawalniczy, automatyczna maszyna czyszcz\u0105ca, automatyczna maszyna do monta\u017cu cylindr\u00f3w i automatyczna linia produkcyjna do malowania. Istniej\u0105cy krytyczny sprz\u0119t sk\u0142ada si\u0119 z ponad 300 zestaw\u00f3w. Optymalna alokacja i efektywne wykorzystanie zasob\u00f3w sprz\u0119towych zapewniaj\u0105 wymagania dotycz\u0105ce dok\u0142adno\u015bci produkt\u00f3w i spe\u0142niaj\u0105 potrzeby wysokiej jako\u015bci produkt\u00f3w.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Obr\u00f3bka<\/h3>\n<p>Warsztat obr\u00f3bki skrawaniem jest wyposa\u017cony w niestandardowe centrum tokarskie z pochylon\u0105 szyn\u0105, centrum obr\u00f3bcze, szybkobie\u017cn\u0105 honownic\u0119, robota spawalniczego i inny powi\u0105zany sprz\u0119t, kt\u00f3ry mo\u017ce obs\u0142ugiwa\u0107 przetwarzanie rur cylindrycznych o maksymalnej \u015brednicy wewn\u0119trznej 400 mm i maksymalnej d\u0142ugo\u015bci 6 metr\u00f3w.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Spawanie<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Malowanie i powlekanie<\/h3>\n<p>Z ma\u0142ymi i \u015brednimi automatycznymi liniami do powlekania farbami na bazie wody, w celu osi\u0105gni\u0119cia automatycznego za\u0142adunku i roz\u0142adunku robota oraz automatycznego natryskiwania, wydajno\u015b\u0107 projektowa 4000 sztuk na zmian\u0119;<br \/>\nPosiadamy r\u00f3wnie\u017c p\u00f3\u0142automatyczn\u0105 lini\u0119 do produkcji farb do du\u017cych cylindr\u00f3w nap\u0119dzan\u0105 \u0142a\u0144cuchem nap\u0119dowym, o wydajno\u015bci 60 skrzy\u0144 na zmian\u0119.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testowanie<\/h3>\n<p>Dysponujemy najwy\u017cszej klasy urz\u0105dzeniami kontrolnymi i stanowiskami testowymi, aby zapewni\u0107, \u017ce wydajno\u015b\u0107 cylindra spe\u0142nia wymagania.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Jeste\u015bmy jednym z najlepszych producent\u00f3w cylindr\u00f3w hydraulicznych. Oferujemy kompleksow\u0105 ofert\u0119 cylindr\u00f3w hydraulicznych. Dostarczamy r\u00f3wnie\u017c\u2026 <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">przek\u0142adnie rolnicze<\/a>. Eksportowali\u015bmy nasze produkty do klient\u00f3w na ca\u0142ym \u015bwiecie i zdobyli\u015bmy dobr\u0105 reputacj\u0119 dzi\u0119ki najwy\u017cszej jako\u015bci produkt\u00f3w i us\u0142ug posprzeda\u017cnych. Zapraszamy klient\u00f3w w kraju i za granic\u0105 do kontaktu z nami w celu negocjacji biznesowych, wymiany informacji i <a href=\"https:\/\/www.hydraulic-cylinders.net\/pl\/contact-us\/\">wsp\u00f3\u0142pracowa\u0107 z nami<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WEH Series Directional Hydraulic Valves Of Pilot Operated The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility. The WEH series directional hydraulic valves of pilot operated are [&hellip;]<\/p>","protected":false},"featured_media":2072,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2055","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product\/2055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/comments?post=2055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/media\/2072"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/media?parent=2055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_brand?post=2055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_cat?post=2055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_tag?post=2055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}