{"id":2208,"date":"2023-11-01T07:43:01","date_gmt":"2023-11-01T07:43:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2208"},"modified":"2023-11-01T07:43:02","modified_gmt":"2023-11-01T07:43:02","slug":"4wrle-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/pl\/produkt\/4wrle-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2219\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrle-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The 4WRLE series pilot-operated proportional directional hydraulic valve is a cutting-edge hydraulic component that revolutionizes fluid control in hydraulic systems. This valve combines pilot-operated technology with proportional directional control, offering precise flow regulation and exceptional efficiency.<\/p>\n<p>The 4WRLE series pilot-operated proportional directional hydraulic valve elevates hydraulic control to new heights of precision and efficiency. With its pilot-operated technology and proportional directional control, this valve ensures accurate flow regulation, optimized energy consumption, and enhanced system performance. By following the recommended usage methods and maintenance guidelines, you can unleash the full potential of the 4WRLE series valve and achieve superior hydraulic control. Upgrade your hydraulic system today and experience the power of precision with the 4WRLE series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilot Operated Technology:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRLE series valve incorporates pilot-operated technology, allowing precise fluid flow control and pressure regulation.<\/li>\n<li>This technology enables efficient energy usage and reduces heat generation, resulting in improved overall system performance and reduced operating costs.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Proportional Directional Control:<\/li>\n<\/ol>\n<ul>\n<li>With its proportional directional control capability, this valve provides accurate and balanced flow adjustment based on control signals.<\/li>\n<li>The proportional control allows for smooth and precise control of hydraulic actuators, enhancing system performance and minimizing wear and tear.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Wszechstronna funkcjonalno\u015b\u0107:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRLE series valve offers versatile control over fluid direction, making it suitable for a wide range of hydraulic applications.<\/li>\n<li>Whether it&#8217;s controlling cylinders, motors, or other hydraulic components, this valve ensures seamless activation and deactivation in different directions, enhancing system flexibility and adaptability.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Wysoka przepustowo\u015b\u0107:<\/li>\n<\/ol>\n<ul>\n<li>Designed to handle high flow rates, the 4WRLE series valve delivers exceptional performance even in demanding applications.<\/li>\n<li>Its robust construction and optimized flow channels ensure reliable operation and consistent flow control, meeting the requirements of high-power hydraulic systems.<\/li>\n<\/ul>\n<h2><strong>4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<p><strong>NG6<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Og\u00f3lny<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Projekt<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Spool valve, direct operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Aktywacja<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Typ po\u0142\u0105czenia<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Subplate mounting, porting pattern according to ISO 4401-03-02-0-05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Zakres temperatur otoczenia<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Waga<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">about 2.75<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hydrauliczny\u00a0<\/strong>\u00a0 (measured at p=100bar, with HLP46 at \u03d1oil = 40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn ci\u015bnieniowy<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP)to DIN 51 524<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Zakres lepko\u015bci<\/td>\n<td align=\"left\" valign=\"middle\">zalecony<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">maks. dozwolony<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Zakres temperatury p\u0142ynu ci\u015bnieniowego<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20 do +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maksymalny dopuszczalny stopie\u0144 zanieczyszczenia p\u0142ynu ci\u015bnieniowego Klasa czysto\u015bci wg ISO 4406 (c)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Klasa 18\/16\/13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow (\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td align=\"left\" valign=\"middle\">2<\/td>\n<td align=\"left\" valign=\"middle\">4<\/td>\n<td align=\"left\" valign=\"middle\">12<\/td>\n<td align=\"left\" valign=\"middle\">24<\/td>\n<td align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maksymalne ci\u015bnienie robocze<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Port \u00a0A\u3001B\u3001P\uff1a315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. pressure<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Port \u00a0T: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;150<\/td>\n<td align=\"left\" valign=\"middle\">&lt;180<\/td>\n<td align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;500<\/td>\n<td align=\"left\" valign=\"middle\">&lt;900;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td align=\"left\" valign=\"middle\">&lt;450;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Statyczny\/Dynamiczny<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Histereza<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">SM<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electric, control electronics integrated in the valve<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Stopie\u0144 ochrony<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Plug-in connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V (ripple max. 2)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">nput, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (<sub>ID-E<\/sub>)<br \/>\nTerminal E (<sub>ID-E<\/sub>)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (<sub>UTest<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT signal 4 &#8230; (12) &#8230; 20 mA on external load 200 &#8230; 500 \u03a9maximum<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4 &#8230; (12) &#8230; 20mA (output)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Adjustment<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Calibrated before delivery, see characteristic curves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Og\u00f3lny<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Projekt<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Spool valve, directly operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Aktywacja<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Typ po\u0142\u0105czenia<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Plate port, porting pattern (ISO 4401-05-04-0-05)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pozycja instalacji<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Zakres temperatur okoliczno\u015bci<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Waga<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">about 7.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Hydraulic \u00a0 (measured with HLP 46, \u03d1oil =40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">P\u0142yn ci\u015bnieniowy<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic oil according to DIN 51524&#8230;535<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Zakres lepko\u015bci<\/td>\n<td align=\"left\" valign=\"middle\">zalecony<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. permitted<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Zakres temperatury p\u0142ynu ci\u015bnieniowego<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">-20 do +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. admissible degree of contamination of the hydraulic fluid,cleanliness class according to ISO 4406 (c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Klasa 18\/16\/13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow(\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<td colspan=\"2\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maksymalne ci\u015bnienie robocze<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0P A B: 315<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. pressure<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;1200<\/td>\n<td colspan=\"2\">&lt;1500<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;600<\/td>\n<td colspan=\"2\">&lt;600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Statyczny\/Dynamiczny<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Histereza<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">SM<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Electric, control electronics integrated in the valve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Stopie\u0144 ochrony<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">IP65(with mating connector mounted and locked )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Mating connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ripple max. 2 VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (I<sub>D-E<\/sub>)<br \/>\nTerminal E (I<sub>D-E<\/sub>)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (U<sub>Test<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;20 mA output<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0feedback<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Direct-acting servo solenoid valve with control piston and valve sleeve, with servo performance<br \/>\n\u2022 Single-side drive, optional, with power-off safety function<br \/>\nControl solenoid with built-in feedback and integrated amplifier board (OBE), factory preset<br \/>\n\u2022 Electrical connection 6P+PE signal input differential amplifier with interface, input optional A1: \u00b110V, or interface F1: 4&#8230;20mA (Rsh =200\u03a9)<br \/>\n\u2022 Panel mounting: the mounting surface complies with ISO 4401-03-02<\/p>\n<h2><strong>Usage Method Of 4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li>Ocena systemu:<\/li>\n<\/ol>\n<ul>\n<li>Evaluate your hydraulic system and define the specific flow and directional control requirements.<\/li>\n<li>Identify whether the 4WRLE series valve is compatible with your system based on factors such as flow capacity, pressure rating, and compatibility with your application.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Wyb\u00f3r zaworu:<\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRLE series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Consider factors such as maximum flow rate, pressure rating, response time, and environmental operating conditions.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Instalacja:<\/li>\n<\/ol>\n<ul>\n<li>Follow the manufacturer&#8217;s installation instructions carefully to ensure proper alignment and secure valve mounting.<\/li>\n<li>Create leak-free connections and ensure correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Control Signal Integration:<\/li>\n<\/ol>\n<ul>\n<li>Pod\u0142\u0105cz przewody sygna\u0142u steruj\u0105cego zaworu do odpowiedniego urz\u0105dzenia steruj\u0105cego, na przyk\u0142ad wzmacniacza proporcjonalnego lub elektronicznej jednostki steruj\u0105cej.<\/li>\n<li>Ensure proper wiring and compatibility between the valve and control device to achieve accurate and responsive control.<\/li>\n<\/ul>\n<h2><strong>How To Hook Up A Hydraulic Flow Control Valve?<\/strong><\/h2>\n<p>To hook up a hydraulic flow control valve, follow these steps:<\/p>\n<ol>\n<li><strong>Identify Valve Type:<\/strong> Determine the specific type of flow control valve you are working with. Common types include needle valves, adjustable flow control valves, or pressure-compensated flow control valves. Ensure that the valve is suitable for your application and compatible with your hydraulic system.<\/li>\n<li><strong>Gather Required Tools and Materials:<\/strong> Collect the necessary tools and materials, including appropriate hydraulic fittings, adapters, hoses, and wrenches.<\/li>\n<li><strong>Prepare the Hydraulic System:<\/strong> Shut down the hydraulic system and relieve any pressure in the system by activating the relief valve or retracting any hydraulic cylinders. This step is crucial for safety.<\/li>\n<li><strong>Identify Flow Direction:<\/strong> Identify the flow direction in your hydraulic system. Typically, the flow direction is indicated by arrows on the hydraulic components. Ensure that you understand the correct flow direction before proceeding.<\/li>\n<li><strong>Locate Installation Point:<\/strong> Determine the optimal location to install the flow control valve in your hydraulic system. Consider factors such as accessibility, proximity to the actuator or hydraulic component, and ease of adjustment.<\/li>\n<li><strong>Mount the Valve:<\/strong> Securely mount the flow control valve in the chosen location using appropriate brackets or clamps. Ensure the valve is positioned correctly, aligning the inlet and outlet ports with the flow direction.<\/li>\n<li><strong>Connect the Inlet and Outlet Ports:<\/strong> Attach hydraulic hoses or tubing to the inlet and outlet ports of the flow control valve. Use suitable hydraulic fittings and adapters to create a leak-free connection. Tighten the connections using wrenches to ensure a secure fit, but avoid over-tightening.<\/li>\n<li><strong>Adjust the Flow Control:<\/strong> Depending on the type of flow control valve, it may have adjustable features such as a needle valve or a flow control knob. Adjust the valve according to your desired flow rate or speed. Refer to the manufacturer&#8217;s instructions for specific adjustment procedures.<\/li>\n<li><strong>Przetestuj system:<\/strong> Once the flow control valve is installed and adjusted, slowly restore hydraulic system pressure. Test the system to ensure that the flow control valve is functioning correctly. Monitor the flow rate or speed of the hydraulic actuator to verify that it is within the desired range.<\/li>\n<li><strong>Fine-tune and Monitor:<\/strong> Adjust the flow control valve to achieve the desired flow rate or speed. Regularly monitor the hydraulic system for leaks, pressure inconsistencies, or unusual behavior.<\/li>\n<\/ol>\n<h2><strong>Mo\u017cliwo\u015bci i pojemno\u015b\u0107 fabryki:<\/strong><\/h2>\n<h3>(1) Monta\u017c<\/h3>\n<p>Dysponujemy najwy\u017cszej klasy niezale\u017cn\u0105 platform\u0105 badawczo-rozwojow\u0105. Warsztat produkcji si\u0142ownik\u00f3w hydraulicznych posiada cztery p\u00f3\u0142automatyczne linie monta\u017cowe si\u0142ownik\u00f3w podnosz\u0105cych i jedn\u0105 automatyczn\u0105 lini\u0119 monta\u017cow\u0105 si\u0142ownik\u00f3w przechy\u0142u, o projektowanej rocznej zdolno\u015bci produkcyjnej 1 miliona sztuk. Specjalny warsztat cylindr\u00f3w jest wyposa\u017cony w r\u00f3\u017cne specyfikacje p\u00f3\u0142automatycznego systemu monta\u017cu czyszcz\u0105cego o projektowanej rocznej zdolno\u015bci produkcyjnej 200 000 i wyposa\u017cony w s\u0142ynny sprz\u0119t do obr\u00f3bki CNC, centrum obr\u00f3bcze, specjalny sprz\u0119t do precyzyjnej obr\u00f3bki cylindr\u00f3w, robot spawalniczy, automatyczna maszyna czyszcz\u0105ca, automatyczna maszyna do monta\u017cu cylindr\u00f3w i automatyczna linia produkcyjna do malowania. Istniej\u0105cy krytyczny sprz\u0119t sk\u0142ada si\u0119 z ponad 300 zestaw\u00f3w. Optymalna alokacja i efektywne wykorzystanie zasob\u00f3w sprz\u0119towych zapewniaj\u0105 wymagania dotycz\u0105ce dok\u0142adno\u015bci produkt\u00f3w i spe\u0142niaj\u0105 potrzeby wysokiej jako\u015bci produkt\u00f3w.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Obr\u00f3bka<\/h3>\n<p>Warsztat obr\u00f3bki skrawaniem jest wyposa\u017cony w niestandardowe centrum tokarskie z pochylon\u0105 szyn\u0105, centrum obr\u00f3bcze, szybkobie\u017cn\u0105 honownic\u0119, robota spawalniczego i inny powi\u0105zany sprz\u0119t, kt\u00f3ry mo\u017ce obs\u0142ugiwa\u0107 przetwarzanie rur cylindrycznych o maksymalnej \u015brednicy wewn\u0119trznej 400 mm i maksymalnej d\u0142ugo\u015bci 6 metr\u00f3w.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Spawanie<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Malowanie i powlekanie<\/h3>\n<p>Z ma\u0142ymi i \u015brednimi automatycznymi liniami do powlekania farbami na bazie wody, w celu osi\u0105gni\u0119cia automatycznego za\u0142adunku i roz\u0142adunku robota oraz automatycznego natryskiwania, wydajno\u015b\u0107 projektowa 4000 sztuk na zmian\u0119;<br \/>\nPosiadamy r\u00f3wnie\u017c p\u00f3\u0142automatyczn\u0105 lini\u0119 do produkcji farb do du\u017cych cylindr\u00f3w nap\u0119dzan\u0105 \u0142a\u0144cuchem nap\u0119dowym, o wydajno\u015bci 60 skrzy\u0144 na zmian\u0119.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testowanie<\/h3>\n<p>Dysponujemy najwy\u017cszej klasy urz\u0105dzeniami kontrolnymi i stanowiskami testowymi, aby zapewni\u0107, \u017ce wydajno\u015b\u0107 cylindra spe\u0142nia wymagania.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Jeste\u015bmy jednym z najlepszych producent\u00f3w cylindr\u00f3w hydraulicznych. Oferujemy kompleksow\u0105 ofert\u0119 cylindr\u00f3w hydraulicznych. Dostarczamy r\u00f3wnie\u017c\u2026 <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">przek\u0142adnie rolnicze<\/a>. Eksportowali\u015bmy nasze produkty do klient\u00f3w na ca\u0142ym \u015bwiecie i zdobyli\u015bmy dobr\u0105 reputacj\u0119 dzi\u0119ki najwy\u017cszej jako\u015bci produkt\u00f3w i us\u0142ug posprzeda\u017cnych. Zapraszamy klient\u00f3w w kraju i za granic\u0105 do kontaktu z nami w celu negocjacji biznesowych, wymiany informacji i <a href=\"https:\/\/www.hydraulic-cylinders.net\/pl\/contact-us\/\">wsp\u00f3\u0142pracowa\u0107 z nami<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRLE Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRLE series pilot-operated proportional directional hydraulic valve is a cutting-edge hydraulic component that revolutionizes fluid control in hydraulic systems. This valve combines pilot-operated technology with proportional directional control, offering precise flow regulation and exceptional efficiency. The 4WRLE series pilot-operated proportional directional hydraulic valve elevates hydraulic control [&hellip;]<\/p>","protected":false},"featured_media":2220,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2208","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product\/2208","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/comments?post=2208"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/media\/2220"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/media?parent=2208"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_brand?post=2208"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_cat?post=2208"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/pl\/wp-json\/wp\/v2\/product_tag?post=2208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}