{"id":2205,"date":"2023-11-01T03:32:55","date_gmt":"2023-11-01T03:32:55","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2205"},"modified":"2023-11-01T03:53:47","modified_gmt":"2023-11-01T03:53:47","slug":"4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/ro\/produs\/4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2213\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrzhe-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRZ\/H(E) series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilot-Operated Proportional Control<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>This feature ensures accurate and responsive control, resulting in improved system performance, reduced energy consumption, and enhanced productivity.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Versatile Directional Control<\/li>\n<\/ol>\n<ul>\n<li>This valve offers versatile control over hydraulic fluid direction, making it suitable for a wide range of applications.<\/li>\n<li>It enables seamless activation and deactivation of hydraulic components such as cylinders, motors, and actuators in different directions, enhancing system flexibility and adaptability.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>High Flow Capacity<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Its robust construction ensures reliable performance even under demanding conditions, providing consistent and efficient flow control.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Eficien\u021b\u0103 energetic\u0103<\/li>\n<\/ol>\n<ul>\n<li>By incorporating pilot-operated proportional control, this valve minimizes pressure drops and optimizes energy usage.<\/li>\n<li>It helps reduce energy consumption, resulting in cost savings and environmental benefits.<\/li>\n<\/ul>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>GeneraL<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Instalare<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Optional,preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Storage temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 p\u00e2n\u0103 la +80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ambient temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 \u00a0to +70<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 to +50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Greutate<\/td>\n<td align=\"left\" valign=\"middle\">NS 10<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 16<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.4<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 25<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.4<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 32<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.4<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hidraulic\u00a0<\/strong>\u00a0\u00a0 (measured with HLPAG.p=100bar : 40 \u2103 \u00b1 5 \u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Dimensiune<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Presiunea de func\u021bionare<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td align=\"left\" valign=\"middle\">External pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">30 to 100 bar<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Internal pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100 to 350 with &#8220;D3&#8221; only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Main valve<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Return pressure<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (Port R) (external pilot oil drain))<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (internal pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Portul Y<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pilot oil volume input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">cm<sup>3<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">1.7<\/td>\n<td align=\"left\" valign=\"middle\">4.6<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">26.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Pilot oil flow in port X and Y with a stepped input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">3.5<\/td>\n<td align=\"left\" valign=\"middle\">5.5<\/td>\n<td align=\"left\" valign=\"middle\">7<\/td>\n<td align=\"left\" valign=\"middle\">15.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of the main valve<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td align=\"left\" valign=\"middle\">to 170<\/td>\n<td align=\"left\" valign=\"middle\">to 460<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0 to 870<\/td>\n<td align=\"left\" valign=\"middle\">to 1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Fluid hidraulic<\/td>\n<td align=\"left\" valign=\"middle\">L\/min<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP) to DIN 51524 Further fluids on enquiry<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic fluid temperature range<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 \u00a0to +80(preferably +40 to +50)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Interval de v\u00e2scozitate<\/td>\n<td align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">20 \u00a0to 380(preferably 30 to 46)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">Gradul de contaminare<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 or ISO 4406(c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x \u2265 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 7<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Main valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 9<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Histerezis<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u22646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electrical<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Type of protection of the valve to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65 with cable socket mounted and locked<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Tip de tensiune<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value overlap<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. current<\/td>\n<td align=\"left\" valign=\"middle\">O<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Solenoid coil resisance<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Cold value at 20\u2103<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Valoare maxim\u0103 de \u00eenc\u0103lzire<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Cyclic duration factor<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperatura bobinei<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">to 150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Protec\u021bie valv\u0103 conform EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Control electronics<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">External amplifier for type WRZ<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">VT- VSPA2-L2X\/&#8230;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Semnalul valorii de comand\u0103<\/td>\n<td align=\"left\" valign=\"middle\">-Voltage input &#8220;A1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">V.<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00b110<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">&#8211;Current input &#8220;F1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">mA<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">4 to 20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve, used to control the size and direction of the liquid flow<br \/>\n\u2022 Threaded connection type proportional solenoid, the coil can be disassembled separately<br \/>\n\u2022 Sub-plate mounting connection structure, connection size conforms to DIN2430 and ISO4401 standards<br \/>\n\u2022 Aliniere a arcului bobinei<br \/>\n\u2022 WRZE type with integrated proportional amplifierr<br \/>\n\u2022 WRZ type external amplifier (order separately)<\/p>\n<h2><strong>Usage Method Of 4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>System Evaluation<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Evaluate your hydraulic system and identify the specific flow and directional control requirements.<\/li>\n<li>Determine if the 4WRZ\/H(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Valve Selection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRZ\/H(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Lua\u021bi \u00een considerare factori precum debitul maxim, presiunea nominal\u0103, timpul de r\u0103spuns \u0219i condi\u021biile de func\u021bionare.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Instalare<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Follow the manufacturer&#8217;s installation instructions carefully, ensuring proper alignment and secure mounting of the valve.<\/li>\n<li>Make leak-free connections and ensure the correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Control Signal Connection<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Connect the control signal wires of the valve to a suitable control device, such as a proportional amplifier or electronic control unit.<\/li>\n<li>Ensure proper wiring and compatibility between the valve and the control device for accurate and responsive control.<\/li>\n<\/ul>\n<h2><strong>How To Bleed Hydraulic Control Valve?<\/strong><\/h2>\n<p>Bleeding a hydraulic control valve is an essential maintenance procedure to remove any trapped air or gas from the system, ensuring optimal performance and efficiency. Here&#8217;s a step-by-step guide on how to bleed a hydraulic control valve:<\/p>\n<ol>\n<li><strong>Preg\u0103ti\u021bi sistemul:<\/strong>\n<ul>\n<li>Ensure that the hydraulic system is turned off and that the pressure is relieved. This step is crucial for your safety and to prevent any accidental movement or release of high-pressure fluids.<\/li>\n<li>Locate the bleeder valve or bleed screw on the hydraulic control valve. It is typically located on the top or side of the valve body and may have a protective cap or cover.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Positioning and Safety Measures:<\/strong>\n<ul>\n<li>Place a suitable container or absorbent material beneath the bleed valve to catch any fluid that may be expelled during the bleeding process.<\/li>\n<li>Wear appropriate personal protective equipment (PPE), such as safety goggles and gloves, to protect yourself from hydraulic fluid splashes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Opening the Bleed Valve:<\/strong>\n<ul>\n<li>Using an appropriate wrench or tool, carefully loosen the bleed valve or screw counterclockwise. Be cautious not to fully remove it at this stage.<\/li>\n<li>The bleed valve may have an O-ring or sealing washer. Take note of its position and ensure it is in good condition.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Activation:<\/strong>\n<ul>\n<li>Activate the hydraulic system by turning on the power source, such as an engine or hydraulic pump.<\/li>\n<li>Operate the control mechanism associated with the hydraulic control valve, such as a joystick or lever, to allow fluid flow through the valve.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bleeding Process:<\/strong>\n<ul>\n<li>Slowly open the bleed valve by turning it counterclockwise until you start to see hydraulic fluid or air bubbles escaping from the valve.<\/li>\n<li>Allow the fluid to flow for a few seconds or until you observe a steady stream of fluid without any air bubbles. This indicates that the air has been purged from the system.<\/li>\n<li>Be cautious not to open the bleed valve too much, as it may lead to excessive fluid loss or system damage.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Closing the Bleed Valve:<\/strong>\n<ul>\n<li>Once you have successfully bled the system, close the bleed valve by turning it clockwise. Ensure it is tightened securely but avoid over-tightening.<\/li>\n<li>Check for any leaks around the bleed valve or other connections. If you notice any leaks, address them promptly to prevent further issues.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Check:<\/strong>\n<ul>\n<li>Turn off the hydraulic system and inspect the fluid level in the reservoir. Add hydraulic fluid as necessary to maintain the recommended level.<\/li>\n<li>Test the operation of the hydraulic control valve and associated components to ensure proper functionality.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Capabilitatea \u0219i capacitatea fabricii:<\/strong><\/h2>\n<h3>(1) Montaj<\/h3>\n<p>Avem o platform\u0103 de asamblare independent\u0103 de cercetare \u0219i dezvoltare de prim\u0103 clas\u0103. Atelierul de produc\u021bie a cilindrilor hidraulici are patru linii de asamblare semiautomate pentru cilindri de ridicare \u0219i o linie de asamblare automat\u0103 a cilindrilor de \u00eenclinare, cu o capacitate de produc\u021bie anual\u0103 proiectat\u0103 de 1 milion de buc\u0103\u021bi. Atelierul de cilindri speciali este echipat cu diverse specifica\u021bii ale unui sistem de asamblare semi-automat de cur\u0103\u021bare, cu o capacitate de produc\u021bie anual\u0103 proiectat\u0103 de 200.000 \u0219i dotat cu echipamente celebre de prelucrare CNC, un centru de prelucrare, un echipament special de prelucrare a cilindrilor de \u00eenalt\u0103 precizie, o ma\u0219in\u0103 de sudur\u0103 robotizat\u0103, o ma\u0219in\u0103 de cur\u0103\u021bare automat\u0103, o ma\u0219in\u0103 de asamblare automat\u0103 a cilindrilor \u0219i o linie de produc\u021bie automat\u0103 de vopsire. Echipamente critice existente de peste 300 de seturi (seturi). Alocarea optim\u0103 \u0219i utilizarea eficient\u0103 a resurselor de echipamente asigur\u0103 cerin\u021bele de precizie ale produselor \u0219i satisface nevoile de \u00eenalt\u0103 calitate ale produselor.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Prelucrare<\/h3>\n<p>Atelierul de prelucrare este echipat cu un centru de strunjire cu \u0219in\u0103 \u00eenclinat\u0103 personalizat, un centru de prelucrare, o ma\u0219in\u0103 de honuire de mare vitez\u0103, un robot de sudur\u0103 \u0219i alte echipamente conexe, care pot gestiona prelucrarea tuburilor cilindrice cu un diametru interior maxim de 400 mm \u0219i o lungime maxim\u0103 de 6 metri.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Sudur\u0103<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Vopsire \u0219i acoperire<\/h3>\n<p>Cu linii automate de acoperire cu vopsea pe baz\u0103 de ap\u0103 cu cilindru de dimensiuni mici \u0219i medii, pentru a realiza \u00eenc\u0103rcarea \u0219i desc\u0103rcarea automat\u0103 a robotului \u0219i pulverizarea automat\u0103, capacitatea de proiectare de 4000 de buc\u0103\u021bi pe schimb;<br \/>\nAvem, de asemenea, o linie de produc\u021bie semi-automat\u0103 de vopsire pentru cilindri mari, ac\u021bionat\u0103 de un lan\u021b de putere, cu o capacitate de proiectare de 60 de cutii pe schimb.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testarea<\/h3>\n<p>Dispunem de instala\u021bii de inspec\u021bie \u0219i bancuri de testare de prim\u0103 clas\u0103 pentru a ne asigura c\u0103 performan\u021ba cilindrului \u00eendepline\u0219te cerin\u021bele.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Suntem unul dintre cei mai buni produc\u0103tori de cilindri hidraulici. Putem oferi o gam\u0103 complet\u0103 de cilindri hidraulici. De asemenea, oferim... <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">cutii de viteze agricole<\/a>Ne-am exportat produsele c\u0103tre clien\u021bi din \u00eentreaga lume \u0219i ne-am c\u00e2\u0219tigat o bun\u0103 reputa\u021bie datorit\u0103 calit\u0103\u021bii superioare a produselor noastre \u0219i a serviciilor post-v\u00e2nzare. \u00cei invit\u0103m pe clien\u021bii din \u021bar\u0103 \u0219i din str\u0103in\u0103tate s\u0103 ne contacteze pentru a negocia afaceri, a face schimb de informa\u021bii \u0219i... <a href=\"https:\/\/www.hydraulic-cylinders.net\/ro\/contact-us\/\">s\u0103 coopereze cu noi<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2214,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/product\/2205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/comments?post=2205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/media\/2214"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/media?parent=2205"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/product_brand?post=2205"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/product_cat?post=2205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/ro\/wp-json\/wp\/v2\/product_tag?post=2205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}