{"id":2055,"date":"2023-10-25T08:13:01","date_gmt":"2023-10-25T08:13:01","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2055"},"modified":"2023-10-25T08:13:02","modified_gmt":"2023-10-25T08:13:02","slug":"weh-series-directional-hydraulic-valves-of-pilot-operated","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/sl\/izdelek\/weh-series-directional-hydraulic-valves-of-pilot-operated\/","title":{"rendered":"Pilotno upravljani smerni hidravli\u010dni ventili serije WEH"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>Pilotno upravljani smerni hidravli\u010dni ventili serije WEH<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2071\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/weh-series-directional-hydraulic-valves-of-pilot-operated-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility.<\/p>\n<p>The WEH series directional hydraulic valves of pilot operated are reliable, high-performance components that empower operators with precise control and efficient fluid management in hydraulic systems. With their pilot-operated design, exceptional directional control, a wide range of configurations, and high flow capacity, these valves offer the reliability and versatility required in various industries. Following the recommended usage methods and adhering to regular maintenance practices, the WEH series valves will continue delivering\u00a0exceptional performance. Upgrade your hydraulic system with the WEH series directional hydraulic valves operated and experience the benefits of precision, control, and reliability.<\/p>\n<p>WEH Series Directional Hydraulic Valves Of Pilot Operated Key Characteristics:<\/p>\n<ul>\n<li>Pilot Operated Design:\n<ul>\n<li>The WEH series valves utilize a pilot-operated design, which enhances their responsiveness and control accuracy.<\/li>\n<li>This design enables the valves to handle high-pressure applications, ensuring optimal performance easily.<\/li>\n<\/ul>\n<\/li>\n<li>Smerni nadzor:\n<ul>\n<li>These hydraulic valves excel in providing precise directional control of hydraulic fluid.<\/li>\n<li>Operaterji lahko enostavno upravljajo pretok teko\u010dine in ga usmerjajo do razli\u010dnih aktuatorjev ali komponent znotraj hidravli\u010dnega sistema.<\/li>\n<\/ul>\n<\/li>\n<li>Wide Range of Configurations:\n<ul>\n<li>The WEH series valves are available in various configurations, including various sizes, flow rates, and pressure ratings.<\/li>\n<li>This versatility allows them to be tailored to specific application requirements and system specifications.<\/li>\n<\/ul>\n<\/li>\n<li>Visoka preto\u010dnost:\n<ul>\n<li>These valves are designed to handle high flow rates, making them suitable for applications that demand substantial fluid flow.<\/li>\n<li>Njihovi optimizirani notranji prehodi in robustna konstrukcija zagotavljajo minimalen padec tlaka in u\u010dinkovito upravljanje teko\u010din.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Parameter:<\/strong><\/h2>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifikacije<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">WEH10 \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pristani\u0161\u010de T<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pristani\u0161\u010de Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"8\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a07<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Teko\u010dina<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Switching pilot oil volume\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">3-position valve \u00a02.04<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">2-position valve \u00a04.08<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the neutral position to the switched position)\uff08AC and DC \uff09<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0\u00a0ms<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">60<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">55<\/td>\n<td align=\"left\" valign=\"middle\">15<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0\u00a0 ms<\/td>\n<td align=\"left\" valign=\"middle\">35<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">30<\/td>\n<td align=\"left\" valign=\"middle\">75<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">70<\/td>\n<td align=\"left\" valign=\"middle\">20<\/td>\n<td align=\"left\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"11\" align=\"left\" valign=\"middle\">Switching times (= Valve switching time from the switched position to the neutral position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2-position valve \u00a0 \u00a0ms<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">40<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">35<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<td align=\"center\" valign=\"middle\">30<\/td>\n<td align=\"center\" valign=\"middle\">20<\/td>\n<td align=\"center\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Polo\u017eaj namestitve<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">HC\u3001HD\u3001HK\u3001HZ\u3001HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">Te\u017ea<\/td>\n<td align=\"left\" valign=\"middle\">Single solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">6.7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Double solenoid valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">7.1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Switching time regulator kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">1.0<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Reducing valve kg<\/td>\n<td colspan=\"8\" align=\"left\" valign=\"middle\">0.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG16<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifikacije<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH16&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Pristani\u0161\u010de T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pristani\u0161\u010de Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001<br \/>\nF\u3001G\u3001H\u3001P\u3001T\u3001V)bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">3-position valve \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a014<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply ( apply to \u00a0C\u3001Z\u3001F\u3001 G\u3001<br \/>\nH\u3001P\u3001T\u3001V) bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Teko\u010dina<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">5.72<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">11.45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<td align=\"center\" valign=\"middle\">AC<\/td>\n<td align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">58<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">55<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">**Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">45<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Polo\u017eaj namestitve<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 9.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG25<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifikacije<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">WEH25&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Pristani\u0161\u010de T<\/td>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" rowspan=\"2\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pristani\u0161\u010de Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"16\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"3\" align=\"left\" valign=\"middle\">With external pilot oil supply \u00a0( not apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V) \u00a0\u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-centering 3-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a013<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Spring-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Teko\u010dina<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">14.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">28.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">140<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">210<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">40<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">30<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">160<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"19\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">120<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">125<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">95<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">85<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Polo\u017eaj namestitve<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight\u00a0 \u00a0kg<\/td>\n<td colspan=\"16\" align=\"left\" valign=\"middle\">about 18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG32<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Specifikacije<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">WEH32&#8230; \u00a0type<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. operating \u00a0pressure\uff1aP\u3001A\u3001B<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pristani\u0161\u010de T<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">With internal pilot oil drain \u00a0 bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pristani\u0161\u010de Y<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With external pilot oil drain \u00a0bar<\/td>\n<td colspan=\"12\" align=\"center\" valign=\"middle\">DC \u00a0210 AC \u00a0160<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" align=\"left\" valign=\"middle\">Min. control pressure<\/td>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">With external pilot oil supply<\/p>\n<p>With internal pilot oil supply<\/td>\n<td colspan=\"12\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u00a0 \u00a03-position valve \u00a0\u00a0 8.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Spring-return 2-position valve \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Hydraulic-return 2-position valve\u00a0 \u00a0 \u00a0 \u00a015<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">With internal pilot oil supply \u00a0( apply to \u00a0C\u3001Z\u3001F\u3001<br \/>\nG\u3001H\u3001P\u3001T\u3001V)\u00a0 bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. control pressure \u00a0bar<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Teko\u010dina<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">Mineral oil,Phosphate ester<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Fluid temperature range \u00a0 \u2103<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-30 \u00a0to \u00a0+80 ( NBR seals<\/td>\n<\/tr>\n<tr>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">-20 \u00a0to \u00a0+80 ( FKM seals )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viscosity range \u00a0\u00a0mm<sup>2<\/sup>\/s<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">2,8 do 500<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">Switching pilot oil volume<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0\u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">29.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0 \u00a0\u00a0cm<sup>3<\/sup><\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">58.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" align=\"left\" valign=\"middle\">Control pressure \u00a0bar<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">150<\/td>\n<td colspan=\"4\" align=\"center\" valign=\"middle\">250<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">AC<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">80<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">50<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">105<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0\u00a0\u00a0 ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">130<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">75<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">100<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">60<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\" align=\"left\" valign=\"middle\">*Switching times (= Valve switching time from the neutral position to the switched position)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; Spring-centering 3-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">( DC \uff1a50\uff0cAC \uff1a60)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">&#8211; 2-position valve \u00a0 \u00a0ms<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">115<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">90<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">35<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">70<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"middle\">65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Polo\u017eaj namestitve<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">C\u3001D\u3001K\u3001Z\u3001YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of shortest switching time\u00a0 L\/min<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Weight \u00a0kg<\/td>\n<td colspan=\"12\" align=\"left\" valign=\"middle\">about 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"pro_d\">\n<div class=\"wrap\">\n<div class=\"content sidebar-content clearfix\">\n<div class=\"right-cont\">\n<div class=\"show-model-bobx\">\n<div class=\"bottom\">\n<div class=\"val-bar-box\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><strong>WEH Series Directional Hydraulic Valves Of Pilot Operated Advantages:<\/strong><\/h2>\n<p>\u2022 Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool<br \/>\n\u2022 WEH electrohydraulic control<br \/>\n\u2022 Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection<br \/>\n\u2022 Wet DC or AC solenoid (optional)<br \/>\n\u2022 With manual emergency control<br \/>\n\u2022 Electropneumatic connection as single or center connection<br \/>\n\u2022 Spring or hydraulic alignment or bias<\/p>\n<h2><strong>Usage Method Of WEH Series Directional Hydraulic Valves Of Pilot Operated<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li><strong>Sistemska integracija:<\/strong>\n<ul>\n<li>Identify the optimal location for installing the WEH series valves within the hydraulic system, considering the desired flow path and control requirements.<\/li>\n<li>Zagotovite zdru\u017eljivost s specifikacijami tlaka in pretoka sistema.<\/li>\n<li>Ventile varno namestite z ustreznimi nosilci ali monta\u017eno opremo.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Pilot Control Setup:<\/strong>\n<ul>\n<li>Connect the pilot control lines to the designated ports on the valves, following the manufacturer&#8217;s instructions.<\/li>\n<li>Ensure proper sizing and routing of the pilot lines to maintain optimal control signal integrity.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Priklju\u010dki za teko\u010dine:<\/strong>\n<ul>\n<li>Za varne in netesne povezave izberite zdru\u017eljive hidravli\u010dne priklju\u010dke in cevi.<\/li>\n<li>Med namestitvijo upo\u0161tevajte navodila proizvajalca za pravilne vrednosti navora.<\/li>\n<li>Za zagotovitev zanesljivega tesnjenja uporabite ustrezna tesnilna sredstva za navoje ali trak.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Nadzor in prilagajanje:<\/strong>\n<ul>\n<li>To operate the WEH series valves, utilize the recommended control method, such as manual levers or electrical controls.<\/li>\n<li>Adjust the valves&#8217; settings to achieve the desired flow direction and rates, ensuring optimal performance.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How Do Hydraulic Valve Lifters Work?<\/strong><\/h2>\n<p>Hydraulic valve lifters, also known as hydraulic tappets or hydraulic lash adjusters, play a vital role in the proper operation of an internal combustion engine. They are responsible for maintaining the proper clearance, or &#8220;lash,&#8221; between the engine&#8217;s camshaft and valve train components. Here&#8217;s an overview of how hydraulic valve lifters work:<\/p>\n<ol>\n<li><strong>Struktura:<\/strong>\n<ul>\n<li>Hydraulic valve lifters are small cylindrical devices typically made of metal.<\/li>\n<li>They are between the camshaft and the engine&#8217;s valve train components, such as the pushrods, rocker arms, or overhead cam followers.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Hydraulic Operation:<\/strong>\n<ul>\n<li>Inside the hydraulic valve lifter, a small piston mechanism operates based on hydraulic pressure.<\/li>\n<li>The lifter is filled with hydraulic fluid, typically engine oil, which acts as a working fluid.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Camshaft Interaction:<\/strong>\n<ul>\n<li>The camshaft has lobes or eccentric shapes that push against the lifters as it rotates.<\/li>\n<li>As the camshaft lobe comes into contact with the lifter, it applies a force that compresses its internal piston.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Adjustment:<\/strong>\n<ul>\n<li>When the lifter&#8217;s piston is compressed, it pushes the hydraulic fluid out of the lifter through a small orifice.<\/li>\n<li>This hydraulic fluid is expelled into the engine&#8217;s oil galleries or passages.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Lash Compensation:<\/strong>\n<ul>\n<li>The expelled hydraulic fluid creates a hydraulic cushion or &#8220;spring&#8221; effect, compensating for any clearance or lash between the camshaft lobe and the valve train components.<\/li>\n<li>This compensation eliminates excessive clearance and ensures that the valve train remains in constant contact with the camshaft lobes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Maintenance of Lash:<\/strong>\n<ul>\n<li>If there is excessive clearance or lash in the valve train due to wear or other factors, the lifter&#8217;s internal piston will extend further to maintain the necessary hydraulic pressure.<\/li>\n<li>This extended position allows the lifter to take up the additional clearance, thus maintaining proper valve lash.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Oil Pressure and Lubrication:<\/strong>\n<ul>\n<li>The hydraulic valve lifters rely on the engine&#8217;s oil pressure for proper operation.<\/li>\n<li>The oil pump circulates oil through the engine, and the lifters receive a continuous oil supply to maintain hydraulic pressure and lubrication.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Zmogljivost in zmogljivost tovarne:<\/strong><\/h2>\n<h3>(1) Sestavljanje<\/h3>\n<p>Imamo prvovrstno neodvisno platformo za raziskave in razvoj. Delavnica za proizvodnjo hidravli\u010dnih cilindrov ima \u0161tiri polavtomatske monta\u017ene linije za dvi\u017ene cilindre in eno avtomatsko monta\u017eno linijo za nagibne cilindre z letno proizvodno zmogljivostjo 1 milijona kosov. Delavnica za posebne cilindre je opremljena z razli\u010dnimi specifikacijami polavtomatskega sistema za \u010di\u0161\u010denje in monta\u017eo z letno proizvodno zmogljivostjo 200.000 kosov ter znano CNC obdelovalno opremo, obdelovalnim centrom, visoko precizno posebno opremo za obdelavo cilindrov, robotskim varilnim strojem, avtomatskim \u010distilnim strojem, avtomatskim strojem za monta\u017eo cilindrov in avtomatsko proizvodno linijo za barvanje. Obstoje\u010da kriti\u010dna oprema obsega ve\u010d kot 300 kompletov (kompletov). Optimalna razporeditev in u\u010dinkovita uporaba opremnih virov zagotavljata zahteve glede natan\u010dnosti izdelkov in izpolnjujeta visoke zahteve glede kakovosti izdelkov.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Strojna obdelava<\/h3>\n<p>Strojna delavnica je opremljena s prilagojenim centrom za stru\u017eenje nagnjenih tirnic, obdelovalnim centrom, visokohitrostnim strojem za honanje, varilnim robotom in drugo sorodno opremo, ki lahko obdeluje cilindri\u010dne cevi z najve\u010djim notranjim premerom 400 mm in najve\u010djo dol\u017eino 6 metrov.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Varjenje<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Barvanje in premazovanje<\/h3>\n<p>Z majhnimi in srednje velikimi cilindri\u010dnimi avtomatskimi linijami za barvanje na vodni osnovi, za doseganje avtomatskega nakladanja in razkladanja robotov ter avtomatskega brizganja, je projektna zmogljivost 4000 kosov na izmeno;<br \/>\nImamo tudi polavtomatsko linijo za proizvodnjo barv za velike jeklenke, ki jo poganja veriga, s projektno zmogljivostjo 60 zabojev na izmeno.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testiranje<\/h3>\n<p>Imamo prvovrstne in\u0161pekcijske prostore in testne postaje, s katerimi zagotavljamo, da delovanje jeklenke izpolnjuje zahteve.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Smo eden najbolj\u0161ih proizvajalcev hidravli\u010dnih cilindrov. Ponujamo vam celovite hidravli\u010dne cilindre. Zagotavljamo tudi ustrezne <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">kmetijski menjalniki<\/a>Na\u0161e izdelke smo izvozili strankam po vsem svetu in si prislu\u017eili dober ugled zaradi vrhunske kakovosti izdelkov in poprodajnih storitev. Z veseljem vas vabimo, da nas kontaktirate za poslovne dogovore, izmenjavo informacij in ... <a href=\"https:\/\/www.hydraulic-cylinders.net\/sl\/contact-us\/\">sodelujte z nami<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>WEH Series Directional Hydraulic Valves Of Pilot Operated The WEH series directional hydraulic valves of pilot operated are advanced components that provide precise and efficient control over hydraulic systems. Designed to meet the demands of various industries, these valves offer exceptional performance, reliability, and versatility. The WEH series directional hydraulic valves of pilot operated are [&hellip;]<\/p>","protected":false},"featured_media":2072,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2055","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/product\/2055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/comments?post=2055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/media\/2072"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/media?parent=2055"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/product_brand?post=2055"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/product_cat?post=2055"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sl\/wp-json\/wp\/v2\/product_tag?post=2055"}],"curies":[{"name":"delovni list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}