{"id":2207,"date":"2023-11-01T06:24:32","date_gmt":"2023-11-01T06:24:32","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2207"},"modified":"2023-11-01T06:24:33","modified_gmt":"2023-11-01T06:24:33","slug":"4wrpeh-series-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/sv\/produkt\/4wrpeh-series-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRPEH-serien proportionell riktad hydraulisk ventil"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRPEH-serien proportionell riktad hydraulisk ventil<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2217\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrpeh-series-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The 4WRPEH series proportional directional hydraulic valve is an advanced hydraulic component designed to deliver exceptional precision and control in hydraulic systems. With its innovative proportional directional control technology, this valve enables accurate flow regulation and smooth directional changes.<\/p>\n<p>The 4WRPEH series proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile functionality, and enhanced efficiency. Its proportional directional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRPEH series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRPEH series proportional directional hydraulic valve.<\/p>\n<p>4WRPEH Series Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Proportional Directional Control:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRPEH series valve utilizes state-of-the-art proportional directional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>Denna funktion s\u00e4kerst\u00e4ller noggrann och responsiv styrning, vilket resulterar i f\u00f6rb\u00e4ttrad systemprestanda, minskad energif\u00f6rbrukning och \u00f6kad produktivitet.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>M\u00e5ngsidig funktionalitet:<\/li>\n<\/ol>\n<ul>\n<li>Denna ventil erbjuder m\u00e5ngsidig kontroll \u00f6ver hydraulv\u00e4tskeriktningen, vilket g\u00f6r den l\u00e4mplig f\u00f6r en m\u00e4ngd olika till\u00e4mpningar.<\/li>\n<li>Det m\u00f6jligg\u00f6r s\u00f6ml\u00f6s aktivering och avaktivering av hydrauliska komponenter som cylindrar, motorer och st\u00e4lldon i olika riktningar, vilket f\u00f6rb\u00e4ttrar systemets flexibilitet och anpassningsf\u00f6rm\u00e5ga.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>H\u00f6g fl\u00f6deskapacitet:<\/li>\n<\/ol>\n<ul>\n<li>The 4WRPEH series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Dess robusta konstruktion s\u00e4kerst\u00e4ller tillf\u00f6rlitlig prestanda \u00e4ven under kr\u00e4vande f\u00f6rh\u00e5llanden, vilket ger en konsekvent och effektiv fl\u00f6deskontroll.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Precise Metering:<\/li>\n<\/ol>\n<ul>\n<li>With its proportional control technology, this valve offers precise metering of hydraulic fluid, allowing for accurate control and regulation of flow rates.<\/li>\n<li>This precision enhances overall system performance and ensures precise movements of hydraulic actuators.<\/li>\n<\/ul>\n<h2><strong>4WRPEH Series Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<p><strong>NG6<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Allm\u00e4n<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Design<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Spool valve, direct operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Aktivering<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Anslutningstyp<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Subplate mounting, porting pattern according to ISO 4401-03-02-0-05<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Installationsposition<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Omgivningstemperaturintervall<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Vikt<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">about 2.75<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hydraulisk\u00a0<\/strong>\u00a0 (measured at p=100bar, with HLP46 at \u03d1oil = 40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Tryckv\u00e4tska<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP)to DIN 51 524<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Viskositetsomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">rekommenderad<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">max. till\u00e5tet<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Tryckv\u00e4tsketemperaturomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20 \u00a0to +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximal till\u00e5ten f\u00f6roreningsgrad av tryckv\u00e4tska Renhetsklass enligt ISO 4406 (c)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Klass 18\/16\/13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow (\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td align=\"left\" valign=\"middle\">2<\/td>\n<td align=\"left\" valign=\"middle\">4<\/td>\n<td align=\"left\" valign=\"middle\">12<\/td>\n<td align=\"left\" valign=\"middle\">24<\/td>\n<td align=\"left\" valign=\"middle\">40<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. driftstryck<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Port \u00a0A\u3001B\u3001P\uff1a315<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. pressure<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Port \u00a0T: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;150<\/td>\n<td align=\"left\" valign=\"middle\">&lt;180<\/td>\n<td align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;500<\/td>\n<td align=\"left\" valign=\"middle\">&lt;900;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td align=\"left\" valign=\"middle\">\/<\/td>\n<td abbr=\"\" align=\"left\" valign=\"middle\">&lt;300<\/td>\n<td align=\"left\" valign=\"middle\">&lt;450;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Statisk\/Dynamisk<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Hysteres<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">ms<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Electric, control electronics integrated in the valve<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Skyddsgrad<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Plug-in connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V (ripple max. 2)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">nput, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (<sub>ID-E<\/sub>)<br \/>\nTerminal E (<sub>ID-E<\/sub>)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200 \u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (<sub>UTest<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">LVDT signal 4 &#8230; (12) &#8230; 20 mA on external load 200 &#8230; 500 \u03a9maximum<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">4 &#8230; (12) &#8230; 20mA (output)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Adjustment<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Calibrated before delivery, see characteristic curves<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>NG10<\/strong><\/p>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Allm\u00e4n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Design<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Spool valve, directly operated, with steel sleeve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Aktivering<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Proportional solenoid with position control, OBE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Anslutningstyp<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Plate port, porting pattern (ISO 4401-05-04-0-05)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Installationsposition<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Any<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Omst\u00e4ndigheter temperaturintervall<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Vikt<\/td>\n<td align=\"left\" valign=\"middle\">kg<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">about 7.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Maximum vibration resistance (test condition)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. 25 g, space vibration test in all directions (24h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Hydraulic \u00a0 (measured with HLP 46, \u03d1oil =40\u2103 \u00b15\u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Tryckv\u00e4tska<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hydraulic oil according to DIN 51524&#8230;535<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Viskositetsomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">rekommenderad<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">20&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. permitted<\/td>\n<td align=\"left\" valign=\"middle\">mm\u00b2\/s<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">10&#8230;800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Tryckv\u00e4tsketemperaturomr\u00e5de<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">-20 \u00a0to +70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. admissible degree of contamination of the hydraulic fluid,cleanliness class according to ISO 4406 (c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Klass 18\/16\/13<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Rated flow(\u0394p = 35 bar per edge)<\/td>\n<td align=\"left\" valign=\"middle\">l\/min<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<td colspan=\"2\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. driftstryck<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0P A B: 315<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Max. pressure<\/td>\n<td align=\"left\" valign=\"middle\">bar<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T: 250<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Leakage flow at 100 bar<\/td>\n<td align=\"left\" valign=\"middle\">Linear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;1200<\/td>\n<td colspan=\"2\">&lt;1500<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Nonlinear<\/td>\n<td align=\"left\" valign=\"middle\">cm\u00b3\/min<\/td>\n<td align=\"left\" valign=\"middle\">&lt;600<\/td>\n<td colspan=\"2\">&lt;600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Statisk\/Dynamisk<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Hysteres<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">\u22640.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Actuating time for signal step 0 &#8230; 100%<\/td>\n<td align=\"left\" valign=\"middle\">ms<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">25<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Temperature drift<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero shift &lt; 1% at \u0394T=40\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Zero compensation<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ex factory \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" align=\"left\" valign=\"middle\">Electric, control electronics integrated in the valve<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Relative duty cycle<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">100ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Skyddsgrad<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">IP65(with mating connector mounted and locked )<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Connection<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Mating connector 6P+PE, DIN 43563<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Supply voltage<br \/>\nTerminal A<br \/>\nTerminal B<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">24VDC<sub>nom<\/sub><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">min. 21VDC \/ max. 40VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ripple max. 2 VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Fuse protection, external<\/td>\n<td align=\"left\" valign=\"middle\">AF<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;A1&#8221;<br \/>\nTerminal D (U<sub>E<\/sub>)<br \/>\nTerminal E<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Differential amplifier, Ri = 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Input, version &#8220;F1&#8221;<br \/>\nTerminal D (I<sub>D-E<\/sub>)<br \/>\nTerminal E (I<sub>D-E<\/sub>)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Load, R<sub>sh<\/sub>\u00a0= 200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;12&#8230;20mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>D-E<\/sub>\u00a0return<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;A1&#8221;<br \/>\nTerminal F (U<sub>Testa<\/sub>)<br \/>\nTerminal C<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">0&#8230;\u00b110V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Reference 0 V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\" align=\"left\" valign=\"middle\">Test signal, version &#8220;F1&#8221;<br \/>\nTerminal F ( I\u00a0<sub>F-C<\/sub>\u00a0)<br \/>\nTerminal C ( I\u00a0<sub>F-C<\/sub>\u00a0)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">LVDT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">4&#8230;20 mA output<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Current loop I<sub>F-C<\/sub>\u00a0feedback<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRPEH Series Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Direct-acting servo solenoid valve with control piston and valve sleeve, with servo performance<br \/>\n\u2022 Single-side drive, optional with power-off safety function<br \/>\nControl solenoid with built-in feedback and integrated amplifier board (OBE), factory preset<br \/>\n\u2022 Electrical connection 6P+PE signal input differential amplifier with interface, input optional A1: \u00b110V, or interface F1: 4&#8230;20mA (Rsh =200\u03a9)<br \/>\n\u2022 Panel mounting, the mounting surface complies with ISO 4401-03-02<\/p>\n<h2><strong>Usage Method Of 4WRPEH Series Proportional Directional Hydraulic Valve <\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li>Systemutv\u00e4rdering:<\/li>\n<\/ol>\n<ul>\n<li>Utv\u00e4rdera ditt hydraulsystem och identifiera de specifika kraven f\u00f6r fl\u00f6des- och riktningskontroll.<\/li>\n<li>Determine if the 4WRPEH series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>Ventilval:<\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRPEH series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>T\u00e4nk p\u00e5 faktorer som maximal fl\u00f6deshastighet, tryckklassning, reaktionstid och driftsf\u00f6rh\u00e5llanden.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Installation:<\/li>\n<\/ol>\n<ul>\n<li>F\u00f6lj tillverkarens installationsanvisningar noggrant och s\u00e4kerst\u00e4ll korrekt inriktning och s\u00e4ker montering av ventilen.<\/li>\n<li>Make leak-free connections and ensure correct flow direction alignment to guarantee optimal performance.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Control Signal Connection:<\/li>\n<\/ol>\n<ul>\n<li>Anslut ventilens styrsignalledningar till en l\u00e4mplig styrenhet, s\u00e5som en proportionalf\u00f6rst\u00e4rkare eller elektronisk styrenhet.<\/li>\n<li>S\u00e4kerst\u00e4ll korrekt kabeldragning och kompatibilitet mellan ventilen och styrenheten f\u00f6r noggrann och responsiv styrning.<\/li>\n<\/ul>\n<h2><strong>How To Hook Two Hydraulic Valves Together?<\/strong><\/h2>\n<p>Hooking two hydraulic valves together requires careful consideration of the valve types, their functions, and the specific hydraulic system requirements. Here are general guidelines on how to hook two hydraulic valves together:<\/p>\n<ol>\n<li><strong>Identify Valve Types:<\/strong>\n<ul>\n<li>Determine the types of valves you are working with, such as directional control valves, pressure control valves, flow control valves, or any other specific valves required for your system.<\/li>\n<li>Ensure that both valves are compatible in terms of size, pressure ratings, flow capacity, and function.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Understand Valve Functions:<\/strong>\n<ul>\n<li>Familiarize yourself with the functions of each valve. For example, directional control valves regulate fluid flow direction, pressure control valves control system pressure, and flow control valves manage flow rates.<\/li>\n<li>Determine how the combination of these valves will contribute to achieving the desired hydraulic system operation.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Determine Valve Placement:<\/strong>\n<ul>\n<li>Decide where in the hydraulic system you want to install the two valves. Consider factors such as fluid flow path, pressure requirements, and the desired control sequence.<\/li>\n<li>Ensure that the valve placement allows for proper fluid flow and accessibility for maintenance and operation.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Connect Valve Ports:<\/strong>\n<ul>\n<li>Identify the inlet and outlet ports of each valve. These ports may be labeled or indicated in the valve documentation.<\/li>\n<li>Use appropriate hydraulic fittings, adapters, or connectors to connect the ports of the two valves together.<\/li>\n<li>Ensure a secure and leak-free connection by using suitable sealing materials, such as O-rings or thread sealants.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Consider Valve Interactions:<\/strong>\n<ul>\n<li>Evaluate how the interaction between the two valves will affect the hydraulic system&#8217;s overall performance.<\/li>\n<li>Ensure that the combined operation of the valves does not create conflicts or result in unintended consequences, such as pressure spikes, flow restrictions, or unintended movements.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Integrering av styrsignaler:<\/strong>\n<ul>\n<li>If the valves require control signals, such as electrical or pneumatic signals, determine how these signals will be integrated.<\/li>\n<li>Connect the control signal lines of both valves to the appropriate control devices, such as hydraulic control modules, electronic control units, or manual control levers.<\/li>\n<li>Ensure proper wiring, compatibility, and synchronization between the control devices and the valves to achieve the desired control and coordination.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Test and Adjust:<\/strong>\n<ul>\n<li>After hooking the valves together, thoroughly test the hydraulic system to ensure proper operation.<\/li>\n<li>Monitor the system for any issues, such as leaks, excessive pressure drops, or unexpected behavior.<\/li>\n<li>Make necessary adjustments, such as fine-tuning control settings or modifying valve placement if required.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Fabrikens kapacitet och kapacitet:<\/strong><\/h2>\n<h3>(1) Montering<\/h3>\n<p>Vi har en f\u00f6rstklassig oberoende forsknings- och utvecklingsplattform. Verkstaden f\u00f6r tillverkning av hydraulcylindrar har fyra halvautomatiska monteringslinjer f\u00f6r lyftcylindrar och en automatisk monteringslinje f\u00f6r tiltcylindrar, med en planerad \u00e5rlig produktionskapacitet p\u00e5 1 miljon enheter. Specialcylinderverkstaden \u00e4r utrustad med olika specifikationer f\u00f6r ett halvautomatiskt reng\u00f6ringsmonteringssystem med en planerad \u00e5rlig produktionskapacitet p\u00e5 200 000 och utrustad med k\u00e4nd CNC-bearbetningsutrustning, ett fleroperationscenter, en specialutrustning f\u00f6r h\u00f6gprecisionscylindrar, en robotsvetsmaskin, en automatisk reng\u00f6ringsmaskin, en automatisk cylindermonteringsmaskin och en automatisk produktionslinje f\u00f6r m\u00e5lning. Befintlig kritisk utrustning p\u00e5 mer \u00e4n 300 set (set). Optimal allokering och effektiv anv\u00e4ndning av utrustningsresurser s\u00e4kerst\u00e4ller produkternas noggrannhetskrav och uppfyller produkternas h\u00f6ga kvalitetsbehov.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) Maskinbearbetning<\/h3>\n<p>Bearbetningsverkstaden \u00e4r utrustad med en specialanpassad svarvcentral f\u00f6r lutande r\u00e4ls, bearbetningscenter, h\u00f6ghastighetsh\u00f6nsmaskin, svetsrobot och annan relaterad utrustning, som kan hantera bearbetning av cylinderr\u00f6r med en maximal innerdiameter p\u00e5 400 mm och en maximal l\u00e4ngd p\u00e5 6 meter.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Svetsning<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) M\u00e5lning och ytbehandling<\/h3>\n<p>Med sm\u00e5 och medelstora cylindriska automatiska vattenbaserade f\u00e4rgbel\u00e4ggningslinjer, f\u00f6r att uppn\u00e5 automatisk robotlastning och lossning samt automatisk sprutning, \u00e4r den designade kapaciteten 4000 stycken per skift;<br \/>\nVi har \u00e4ven en halvautomatisk f\u00e4rgproduktionslinje f\u00f6r stora cylindrar som drivs av en sl\u00e4pkedja, med en designkapacitet p\u00e5 60 l\u00e5dor per skift.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Testning<\/h3>\n<p>Vi har f\u00f6rstklassiga inspektionsanl\u00e4ggningar och testb\u00e4ddar f\u00f6r att s\u00e4kerst\u00e4lla att cylinderns prestanda uppfyller kraven.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Vi \u00e4r en av de b\u00e4sta tillverkarna av hydraulcylindrar. Vi kan erbjuda ett helt\u00e4ckande utbud av hydraulcylindrar. Vi tillhandah\u00e5ller \u00e4ven motsvarande <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">jordbruksv\u00e4xell\u00e5dor<\/a>Vi har exporterat v\u00e5ra produkter till kunder \u00f6ver hela v\u00e4rlden och f\u00e5tt ett gott rykte tack vare v\u00e5r \u00f6verl\u00e4gsna produktkvalitet och kundservice. Vi v\u00e4lkomnar kunder b\u00e5de hemma och utomlands att kontakta oss f\u00f6r att f\u00f6rhandla aff\u00e4rer, utbyta information och <a href=\"https:\/\/www.hydraulic-cylinders.net\/sv\/contact-us\/\">samarbeta med oss<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRPEH Series Proportional Directional Hydraulic Valve The 4WRPEH series proportional directional hydraulic valve is an advanced hydraulic component designed to deliver exceptional precision and control in hydraulic systems. With its innovative proportional directional control technology, this valve enables accurate flow regulation and smooth directional changes. The 4WRPEH series proportional directional hydraulic valve empowers hydraulic systems [&hellip;]<\/p>","protected":false},"featured_media":2218,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2207","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/product\/2207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/comments?post=2207"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/media\/2218"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/media?parent=2207"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/product_brand?post=2207"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/product_cat?post=2207"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/sv\/wp-json\/wp\/v2\/product_tag?post=2207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}