{"id":2234,"date":"2023-11-02T08:20:00","date_gmt":"2023-11-02T08:20:00","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&p=2234"},"modified":"2023-11-02T08:21:41","modified_gmt":"2023-11-02T08:21:41","slug":"dbe6xe-series-proportional-pressure-relief-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/sv\/produkt\/dbe6xe-series-proportional-pressure-relief-valve\/","title":{"rendered":"DBE6X(E) Series Proportional Pressure Relief Valve"},"content":{"rendered":"

DBE6X(E) Series Proportional Pressure Relief Valve <\/strong><\/h1>\n

\"\"<\/p>\n

The DBE6X(E) series proportional pressure relief valve is a cutting-edge hydraulic component designed to provide precise and efficient pressure control in various industrial applications. With its advanced features, exceptional performance, and robust construction, this valve offers a solution that optimizes system efficiency and enhances overall performance.<\/p>\n

The DBE6X(E) series proportional pressure relief valve offers precise and efficient pressure control for hydraulic systems. With exceptional proportional control, pressure relief function, high flow capacity, and versatility, this valve provides accurate pressure regulation, safeguards system components, and enhances overall performance. By following the recommended usage methods and maintenance guidelines, you can harness the full potential of this valve and achieve optimal results in your hydraulic applications. Upgrade your pressure control system today with the DBE6X(E) series proportional pressure relief valve and experience enhanced performance and reliability.<\/p>\n

DBE6X(E) Series Proportional Pressure Relief Valve Characteristics:<\/p>\n

    \n
  1. Proportional Control:<\/li>\n<\/ol>\n
      \n
    • The DBE6X(E) series valve boasts exceptional proportional control capabilities, allowing precise adjustment of pressure levels.<\/li>\n
    • This advanced control feature ensures accurate pressure regulation tailored to specific system requirements, facilitating efficient and optimized performance.<\/li>\n<\/ul>\n
        \n
      1. Pressure Relief Function:<\/li>\n<\/ol>\n
          \n
        • Equipped with a pressure relief function, this valve effectively regulates pressure by diverting excess fluid flow to maintain a desired setpoint.<\/li>\n
        • By relieving excess pressure, the valve protects system components from potential damage, ensuring reliable and safe operation.<\/li>\n<\/ul>\n
            \n
          1. High Flow Capacity:<\/li>\n<\/ol>\n
              \n
            • The DBE6X(E) series valve is engineered to handle high flow rates, making it suitable for applications requiring substantial fluid volumes.<\/li>\n
            • Its high flow capacity ensures efficient operation even in demanding industrial environments.<\/li>\n<\/ul>\n
                \n
              1. Versatility:<\/li>\n<\/ol>\n
                  \n
                • This valve offers versatility in system integration and is compatible with a wide range of hydraulic setups and applications.<\/li>\n
                • Its adaptability allows for seamless incorporation into existing systems, minimizing downtime and enhancing overall productivity.<\/li>\n<\/ul>\n

                  DBE6X(E) Series Proportional Pressure Relief Valve Parameter:<\/strong><\/h2>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
                  General<\/strong><\/td>\n<\/tr>\n
                  Construction<\/td>\nPilot stage<\/td>\nPoppet valve<\/td>\n<\/tr>\n
                  Main stage<\/td>\nSpool valve<\/td>\n<\/tr>\n
                  Actuation<\/td>\nProportional solenoid without position control, external amplifier<\/td>\n<\/tr>\n
                  Connection type<\/td>\nSubplate, mounting hole configuration NG6 (SIO 4401-03-02-094)<\/td>\n<\/tr>\n
                  Installation position<\/td>\nOptional<\/td>\n<\/tr>\n
                  Circumstances temperature range<\/td>\n\u2103<\/td>\n-20 \u00a0to \u00a0+50<\/td>\n<\/tr>\n
                  Weight<\/td>\nKg<\/td>\n2.2<\/td>\n<\/tr>\n
                  Vibration resistance, test condition<\/td>\nMax. 25 g, shaken in 3 dimensions (24 h)<\/td>\n<\/tr>\n
                  Hydraulic \u00a0( measured with HLP 46, oil = 40\u2103 \u00b15\u2103 )\uff1a<\/strong><\/td>\n<\/tr>\n
                  Pressure fluid<\/td>\nHydraulic oil to DIN 51524…535, other fluids after prior consultation<\/td>\n<\/tr>\n
                  \u00a0Viscosity range<\/td>\nrecommended<\/td>\nmm\u00b2\/s<\/td>\n20…100<\/td>\n<\/tr>\n
                  max. permitted<\/td>\nmm\u00b2\/s<\/td>\n10…800<\/td>\n<\/tr>\n
                  Pressure fluid temperature range<\/td>\n\u2103<\/td>\n-20 \u00a0to \u00a0+80<\/td>\n<\/tr>\n
                  Maximum permitted degree of contamination of pressure fluid Purity class to ISO 4406 (c)<\/td>\nClass 18\/16\/13<\/td>\n<\/tr>\n
                  Direction of flow<\/td>\nSee symbol<\/td>\n<\/tr>\n
                  Max. setting pressure \uff08at Qmaxx = 1 L\/min\uff09<\/td>\nbar<\/td>\n\u00a080<\/td>\n\u00a0180<\/td>\n\u00a0250<\/td>\n\u00a0315<\/td>\n<\/tr>\n
                  Min. settable pressure\uff08\u5f53 Qmin = 1 L\/min\uff09<\/td>\nbar<\/td>\n\u00a07<\/td>\n\u00a08<\/td>\n\u00a09<\/td>\n\u00a010<\/td>\n<\/tr>\n
                  Max. operating \u00a0pressure<\/td>\nbar<\/td>\nPort \u00a0P\uff1a315<\/td>\n<\/tr>\n
                  Port \u00a0T\uff1a250<\/td>\n<\/tr>\n
                  Max. mechanical pressure limitation level,e.g. when solenoid current I>Imax<\/td>\n\u00a0bar<\/td>\n\u00a0< 90<\/td>\n\u00a0< 190<\/td>\n\u00a0< 260<\/td>\n\u00a0< 235<\/td>\n<\/tr>\n
                  Pilot oil flow<\/td>\nL\/min<\/td>\n\u00a0about 0.6<\/td>\n<\/td>\n<\/td>\n<\/td>\n<\/tr>\n
                  Max. flow-rate<\/td>\nL\/min<\/td>\n\u00a040<\/td>\n<\/td>\n<\/td>\n<\/td>\n<\/tr>\n
                  Electrical data<\/strong><\/td>\n<\/tr>\n
                  Cyclic duration factor<\/td>\n\u00a0%<\/td>\n100 ED<\/td>\n<\/tr>\n
                  Degree of protection<\/td>\nIP 65 to DIN 40050 and IEC 14434\/5<\/td>\n<\/tr>\n
                  Solenoid connection<\/td>\nPlug-in connector to DIN 43650\/ISO 4400\uff0cM16X1.5(2P+PE)<\/td>\n<\/tr>\n
                  Valve with solenoid type<\/td>\n0.8A<\/td>\n2.5A<\/td>\n<\/tr>\n
                  Max. solenoid current<\/td>\n\u00a0Imax<\/td>\n0.8A<\/td>\n2.5A<\/td>\n<\/tr>\n
                  Coil resistance R20<\/td>\n\u00a0\u03a9<\/td>\n22<\/td>\n3<\/td>\n<\/tr>\n
                  Max. power consumption at 100% load and operating temperature<\/td>\nVA<\/td>\n25<\/td>\n30<\/td>\n<\/tr>\n
                  Static\/Dynamic\u00a0<\/strong><\/td>\n<\/tr>\n
                  Hysteresis<\/td>\n%<\/td>\n\u2264 4<\/td>\n<\/tr>\n
                  Range of inversion<\/td>\n%<\/td>\n\u22643<\/td>\n<\/tr>\n
                  Manufacturing tolerance for \u00a0Pmax<\/td>\n%<\/td>\n\u226410<\/td>\n<\/tr>\n
                  Response time 100% signal change<\/td>\nms<\/td>\nOn 200 \/ Off<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

                  DBE6X(E) Series Proportional Pressure Relief Valve Advantages:<\/strong><\/h2>\n

                  \u2022 Pilot valve to restrict system pressure (control oil internal only)
                  \n\u2022 Can adjust by controlling the coil current according to the characteristic curve and the selected electronic control unit
                  \n\u2022 Solenoid type Imax=0.8 A or 2.5 A
                  \n\u2022 In the event of electronic control unit failure, the overload protection can function to the highest degree (coil current > Imax)
                  \n\u2022 Used in valve sub-plate mounting, installation hole follows ISO 441-03-02-0-94\uff0c
                  \n\u2022 Cable sockets follows DIN 43650-AM2
                  \n\u2022 External electronic control unit with ramp and valve adjustment function VT-SSPA1-508\/525-L2X\/V0\/*<\/p>\n

                  Usage Method Of DBE6X(E) Series Proportional Pressure Relief Valve<\/strong>:<\/strong><\/h2>\n
                    \n
                  1. System Evaluation:<\/li>\n<\/ol>\n