{"id":2205,"date":"2023-11-01T03:32:55","date_gmt":"2023-11-01T03:32:55","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2205"},"modified":"2023-11-01T03:53:47","modified_gmt":"2023-11-01T03:53:47","slug":"4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/tr\/urun\/4wrz-he-series-pilot-operated-proportional-directional-hydraulic-valve\/","title":{"rendered":"4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2213\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/11\/4wrzhe-series-pilot-operated-proportional-directional-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"401\" \/><\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes.<\/p>\n<p>The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve empowers hydraulic systems with precise flow control, versatile directional changes, and energy efficiency. Its pilot-operated proportional control technology ensures accurate and responsive flow adjustment, while the high flow capacity guarantees reliable performance even in demanding applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and longevity of the 4WRZ\/H(E) series valve, elevating your hydraulic system to new levels of precision and control. Upgrade your hydraulic setup today and experience the power of the 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve.<\/p>\n<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Key Characteristics:<\/p>\n<ol>\n<li>Pilot Taraf\u0131ndan Y\u00f6netilen Oransal Kontrol<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve utilizes pilot-operated proportional control technology, allowing precise and proportional flow adjustment based on control signals.<\/li>\n<li>Bu \u00f6zellik, hassas ve duyarl\u0131 bir kontrol sa\u011flayarak sistem performans\u0131n\u0131n artmas\u0131n\u0131, enerji t\u00fcketiminin azalmas\u0131n\u0131 ve \u00fcretkenli\u011fin artmas\u0131n\u0131 sa\u011flar.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li>\u00c7ok Y\u00f6nl\u00fc Y\u00f6n Kontrol\u00fc<\/li>\n<\/ol>\n<ul>\n<li>Bu valf, hidrolik s\u0131v\u0131 y\u00f6n\u00fc \u00fczerinde \u00e7ok y\u00f6nl\u00fc kontrol sa\u011flayarak \u00e7ok \u00e7e\u015fitli uygulamalar i\u00e7in uygundur.<\/li>\n<li>Silindirler, motorlar ve akt\u00fcat\u00f6rler gibi hidrolik bile\u015fenlerin farkl\u0131 y\u00f6nlerde sorunsuz bir \u015fekilde etkinle\u015ftirilmesini ve devre d\u0131\u015f\u0131 b\u0131rak\u0131lmas\u0131n\u0131 sa\u011flayarak sistem esnekli\u011fini ve uyarlanabilirli\u011fini art\u0131r\u0131r.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li>Y\u00fcksek Ak\u0131\u015f Kapasitesi<\/li>\n<\/ol>\n<ul>\n<li>The 4WRZ\/H(E) series valve is engineered to handle high flow rates, making it ideal for applications that require substantial hydraulic power.<\/li>\n<li>Sa\u011flam yap\u0131s\u0131, zorlu ko\u015fullarda bile g\u00fcvenilir performans sa\u011flayarak tutarl\u0131 ve verimli ak\u0131\u015f kontrol\u00fc sa\u011flar.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li>Enerji Verimlili\u011fi<\/li>\n<\/ol>\n<ul>\n<li>Pilot kumandal\u0131 oransal kontrol\u00fc entegre eden bu vana, bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015flerini en aza indirir ve enerji kullan\u0131m\u0131n\u0131 optimize eder.<\/li>\n<li>Enerji t\u00fcketimini azaltmaya yard\u0131mc\u0131 olur, bu da maliyet tasarrufu ve \u00e7evresel faydalar sa\u011flar.<\/li>\n<\/ul>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\" data-sort=\"sortDisabled\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>GeneraL<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Kurulum<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Optional,preferably horizontal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Depolama s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 ila +80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Ortam s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 ila +70<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">-20 ila +50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" align=\"left\" valign=\"middle\">A\u011f\u0131rl\u0131k<\/td>\n<td align=\"left\" valign=\"middle\">NS 10<\/td>\n<td align=\"left\" valign=\"middle\">kilogram<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.8<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 16<\/td>\n<td align=\"left\" valign=\"middle\">kilogram<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.4<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">13.6<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 25<\/td>\n<td align=\"left\" valign=\"middle\">kilogram<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">18.4<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">NS 32<\/td>\n<td align=\"left\" valign=\"middle\">kilogram<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.2<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">42.4<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Hidrolik\u00a0<\/strong>\u00a0\u00a0 (measured with HLPAG.p=100bar : 40 \u2103 \u00b1 5 \u2103)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Boyut<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">16<\/td>\n<td align=\"left\" valign=\"middle\">25<\/td>\n<td align=\"left\" valign=\"middle\">32<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">\u00c7al\u0131\u015fma bas\u0131nc\u0131<\/td>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td align=\"left\" valign=\"middle\">External pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">30 to 100 bar<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Internal pilot oil supply<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100 to 350 with &#8220;D3&#8221; only<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Ana vana<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<td align=\"left\" valign=\"middle\">to 350<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" align=\"left\" valign=\"middle\">Geri d\u00f6n\u00fc\u015f bas\u0131nc\u0131<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (Port R) (external pilot oil drain))<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td align=\"left\" valign=\"middle\">to 315<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">to 250<\/td>\n<td align=\"left\" valign=\"middle\">150'ye kadar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Port \u00a0T (internal pilot oil drain)<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u00a0Liman Y<\/td>\n<td align=\"left\" valign=\"middle\">\u00e7ubuk<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<td align=\"left\" valign=\"middle\">to 30<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Pilot oil volume input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">cm<sup>3<\/sup><\/td>\n<td align=\"left\" valign=\"middle\">1.7<\/td>\n<td align=\"left\" valign=\"middle\">4.6<\/td>\n<td align=\"left\" valign=\"middle\">10<\/td>\n<td align=\"left\" valign=\"middle\">26.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Pilot oil flow in port X and Y with a stepped input signal 0- 100 %<\/td>\n<td align=\"left\" valign=\"middle\">3.5<\/td>\n<td align=\"left\" valign=\"middle\">5.5<\/td>\n<td align=\"left\" valign=\"middle\">7<\/td>\n<td align=\"left\" valign=\"middle\">15.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Flow of the main valve<\/td>\n<td align=\"left\" valign=\"middle\">L\/dak<\/td>\n<td align=\"left\" valign=\"middle\">to 170<\/td>\n<td align=\"left\" valign=\"middle\">to 460<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0 to 870<\/td>\n<td align=\"left\" valign=\"middle\">to 1600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hidrolik s\u0131v\u0131<\/td>\n<td align=\"left\" valign=\"middle\">L\/dak<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Mineral oil (HL, HLP) to DIN 51524 Further fluids on enquiry<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Hidrolik s\u0131v\u0131 s\u0131cakl\u0131k aral\u0131\u011f\u0131<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">-20 \u00a0to +80(preferably +40 to +50)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Viskozite aral\u0131\u011f\u0131<\/td>\n<td align=\"left\" valign=\"middle\">mm<sup>2<\/sup>\/S<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">20 \u00a0to 380(preferably 30 to 46)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">Kirlilik derecesi<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 or ISO 4406(c)<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">A filter with a minimum retention rate of \u03b2x \u2265 75 is recommended<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Pilot valve<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 7<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=5<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Ana vana<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a0NAS 1638 class 9<\/td>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">x=15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Histerezis<\/td>\n<td colspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" rowspan=\"1\" align=\"left\" valign=\"middle\">\u22646<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Elektrik<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Valve type<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZ<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">WRZE<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Type of protection of the valve to EN 60529<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65 with cable socket mounted and locked<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">Voltaj t\u00fcr\u00fc<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">DC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Command value overlap<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Max. current<\/td>\n<td align=\"left\" valign=\"middle\">A<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">1.5<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"left\" valign=\"middle\">Solenoid coil resisance<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Cold value at 20\u2103<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">4.8<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maksimum s\u0131cak de\u011fer<\/td>\n<td align=\"left\" valign=\"middle\">\u03a9<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">7.2<\/td>\n<td colspan=\"2\" rowspan=\"1\" align=\"left\" valign=\"middle\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">D\u00f6ng\u00fcsel s\u00fcre fakt\u00f6r\u00fc<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\" valign=\"middle\">Bobin s\u0131cakl\u0131\u011f\u0131<\/td>\n<td rowspan=\"1\" align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">150'ye kadar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">EN 60529'a g\u00f6re vana korumas\u0131<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">IP65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"8\" align=\"left\" valign=\"middle\"><strong>Kontrol elektroni\u011fi<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">External amplifier for type WRZ<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">VT- VSPA2-L2X\/&#8230;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">Komut de\u011feri sinyali<\/td>\n<td align=\"left\" valign=\"middle\">-Voltage input &#8220;A1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">V<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00b110<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">&#8211;Current input &#8220;F1&#8221;<\/td>\n<td align=\"left\" valign=\"middle\">mA<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">4 to 20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 Pilot-operated two-stage proportional directional valve, used to control the size and direction of the liquid flow<br \/>\n\u2022 Threaded connection type proportional solenoid, the coil can be disassembled separately<br \/>\n\u2022 Sub-plate mounting connection structure, connection size conforms to DIN2430 and ISO4401 standards<br \/>\n\u2022 Makara yay\u0131 hizalama hizalamas\u0131<br \/>\n\u2022 WRZE type with integrated proportional amplifierr<br \/>\n\u2022 WRZ type external amplifier (order separately)<\/p>\n<h2><strong>Usage Method Of 4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ol>\n<li><strong>Sistem De\u011ferlendirmesi<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Hidrolik sisteminizi de\u011ferlendirin ve \u00f6zel ak\u0131\u015f ve y\u00f6n kontrol gereksinimlerini belirleyin.<\/li>\n<li>Determine if the 4WRZ\/H(E) series valve is suitable based on its flow capacity, pressure rating, and compatibility with your system.<\/li>\n<\/ul>\n<ol start=\"2\">\n<li><strong>Valf Se\u00e7imi<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Select the appropriate variant of the 4WRZ\/H(E) series valve based on your system parameters, flow requirements, and directional control needs.<\/li>\n<li>Maksimum ak\u0131\u015f h\u0131z\u0131, bas\u0131n\u00e7 derecesi, tepki s\u00fcresi ve \u00e7al\u0131\u015fma ko\u015fullar\u0131 gibi fakt\u00f6rleri g\u00f6z \u00f6n\u00fcnde bulundurun.<\/li>\n<\/ul>\n<ol start=\"3\">\n<li><strong>Kurulum<\/strong><\/li>\n<\/ol>\n<ul>\n<li>\u00dcreticinin montaj talimatlar\u0131n\u0131 dikkatlice izleyin, vanan\u0131n do\u011fru hizalanmas\u0131n\u0131 ve g\u00fcvenli bir \u015fekilde monte edilmesini sa\u011flay\u0131n.<\/li>\n<li>S\u0131z\u0131nt\u0131 yapmayan ba\u011flant\u0131lar olu\u015fturun ve en iyi performans\u0131 garanti etmek i\u00e7in do\u011fru ak\u0131\u015f y\u00f6n\u00fc hizalamas\u0131n\u0131 sa\u011flay\u0131n.<\/li>\n<\/ul>\n<ol start=\"4\">\n<li><strong>Kontrol Sinyali Ba\u011flant\u0131s\u0131<\/strong><\/li>\n<\/ol>\n<ul>\n<li>Vanan\u0131n kontrol sinyal kablolar\u0131n\u0131 orant\u0131l\u0131 amplifikat\u00f6r veya elektronik kontrol \u00fcnitesi gibi uygun bir kontrol cihaz\u0131na ba\u011flay\u0131n.<\/li>\n<li>Do\u011fru ve duyarl\u0131 kontrol i\u00e7in vana ile kontrol cihaz\u0131 aras\u0131nda uygun kablolama ve uyumlulu\u011fun sa\u011flanmas\u0131 gerekir.<\/li>\n<\/ul>\n<h2><strong>How To Bleed Hydraulic Control Valve?<\/strong><\/h2>\n<p>Bleeding a hydraulic control valve is an essential maintenance procedure to remove any trapped air or gas from the system, ensuring optimal performance and efficiency. Here&#8217;s a step-by-step guide on how to bleed a hydraulic control valve:<\/p>\n<ol>\n<li><strong>Sistemi Haz\u0131rlay\u0131n:<\/strong>\n<ul>\n<li>Ensure that the hydraulic system is turned off and that the pressure is relieved. This step is crucial for your safety and to prevent any accidental movement or release of high-pressure fluids.<\/li>\n<li>Locate the bleeder valve or bleed screw on the hydraulic control valve. It is typically located on the top or side of the valve body and may have a protective cap or cover.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Positioning and Safety Measures:<\/strong>\n<ul>\n<li>Place a suitable container or absorbent material beneath the bleed valve to catch any fluid that may be expelled during the bleeding process.<\/li>\n<li>Wear appropriate personal protective equipment (PPE), such as safety goggles and gloves, to protect yourself from hydraulic fluid splashes.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Opening the Bleed Valve:<\/strong>\n<ul>\n<li>Using an appropriate wrench or tool, carefully loosen the bleed valve or screw counterclockwise. Be cautious not to fully remove it at this stage.<\/li>\n<li>The bleed valve may have an O-ring or sealing washer. Take note of its position and ensure it is in good condition.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Activation:<\/strong>\n<ul>\n<li>Activate the hydraulic system by turning on the power source, such as an engine or hydraulic pump.<\/li>\n<li>Operate the control mechanism associated with the hydraulic control valve, such as a joystick or lever, to allow fluid flow through the valve.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Bleeding Process:<\/strong>\n<ul>\n<li>Slowly open the bleed valve by turning it counterclockwise until you start to see hydraulic fluid or air bubbles escaping from the valve.<\/li>\n<li>Allow the fluid to flow for a few seconds or until you observe a steady stream of fluid without any air bubbles. This indicates that the air has been purged from the system.<\/li>\n<li>Be cautious not to open the bleed valve too much, as it may lead to excessive fluid loss or system damage.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Closing the Bleed Valve:<\/strong>\n<ul>\n<li>Once you have successfully bled the system, close the bleed valve by turning it clockwise. Ensure it is tightened securely but avoid over-tightening.<\/li>\n<li>Check for any leaks around the bleed valve or other connections. If you notice any leaks, address them promptly to prevent further issues.<\/li>\n<\/ul>\n<\/li>\n<li><strong>System Check:<\/strong>\n<ul>\n<li>Turn off the hydraulic system and inspect the fluid level in the reservoir. Add hydraulic fluid as necessary to maintain the recommended level.<\/li>\n<li>Test the operation of the hydraulic control valve and associated components to ensure proper functionality.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>Fabrikan\u0131n Kapasitesi ve Kapasitesi:<\/strong><\/h2>\n<h3>(1) Meclis<\/h3>\n<p>Birinci s\u0131n\u0131f ba\u011f\u0131ms\u0131z bir ara\u015ft\u0131rma ve geli\u015ftirme montaj platformumuz bulunmaktad\u0131r. Hidrolik silindir \u00fcretim at\u00f6lyemizde, y\u0131ll\u0131k 1 milyon adet \u00fcretim kapasitesine sahip d\u00f6rt adet yar\u0131 otomatik kald\u0131rma silindiri montaj hatt\u0131 ve bir adet otomatik devirme silindiri montaj hatt\u0131 bulunmaktad\u0131r. \u00d6zel silindir at\u00f6lyemiz, y\u0131ll\u0131k 200.000 adet \u00fcretim kapasitesine sahip \u00e7e\u015fitli \u00f6zelliklerde yar\u0131 otomatik temizleme montaj sistemiyle donat\u0131lm\u0131\u015ft\u0131r. Ayr\u0131ca, \u00fcnl\u00fc CNC i\u015fleme ekipmanlar\u0131, bir i\u015fleme merkezi, y\u00fcksek hassasiyetli silindir i\u015fleme \u00f6zel ekipmanlar\u0131, bir robot kaynak makinesi, bir otomatik temizleme makinesi, otomatik silindir montaj makinesi ve otomatik boyama \u00fcretim hatt\u0131 ile donat\u0131lm\u0131\u015ft\u0131r. 300'den fazla setten olu\u015fan kritik ekipmanlar mevcuttur. Ekipman kaynaklar\u0131n\u0131n optimum da\u011f\u0131l\u0131m\u0131 ve verimli kullan\u0131m\u0131, \u00fcr\u00fcnlerin hassasiyet gereksinimlerini kar\u015f\u0131lar ve \u00fcr\u00fcnlerin y\u00fcksek kalite ihtiya\u00e7lar\u0131n\u0131 kar\u015f\u0131lar.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) \u0130\u015fleme<\/h3>\n<p>\u0130\u015fleme at\u00f6lyesi, maksimum 400 mm i\u00e7 \u00e7apa ve maksimum 6 metre uzunlu\u011fa sahip silindir borular\u0131n\u0131n i\u015flenmesini ger\u00e7ekle\u015ftirebilen \u00f6zel e\u011fimli ray torna merkezi, i\u015fleme merkezi, y\u00fcksek h\u0131zl\u0131 honlama makinesi, kaynak robotu ve di\u011fer ilgili ekipmanlarla donat\u0131lm\u0131\u015ft\u0131r.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) Kaynak<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) Boyama ve kaplama<\/h3>\n<p>K\u00fc\u00e7\u00fck ve orta \u00f6l\u00e7ekli silindirli otomatik su bazl\u0131 boya kaplama hatlar\u0131nda, otomatik robot y\u00fckleme-bo\u015faltma ve otomatik p\u00fcsk\u00fcrtmeyi ger\u00e7ekle\u015ftirmek i\u00e7in, vardiya ba\u015f\u0131na 4000 adet tasar\u0131m kapasitesi;<br \/>\nAyr\u0131ca, vardiya ba\u015f\u0131na 60 kasa kapasiteli, g\u00fc\u00e7 zinciriyle \u00e7al\u0131\u015fan b\u00fcy\u00fck silindirler i\u00e7in yar\u0131 otomatik boya \u00fcretim hatt\u0131m\u0131z da bulunmaktad\u0131r.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) Test etme<\/h3>\n<p>Silindirin performans\u0131n\u0131n gereklilikleri kar\u015f\u0131lad\u0131\u011f\u0131ndan emin olmak i\u00e7in birinci s\u0131n\u0131f muayene tesislerimiz ve test yataklar\u0131m\u0131z bulunmaktad\u0131r.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>En iyi hidrolik silindir \u00fcreticilerinden biriyiz. Kapsaml\u0131 hidrolik silindirler sunabiliyoruz. Ayr\u0131ca, ilgili hidrolik silindirleri de sa\u011fl\u0131yoruz. <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">tar\u0131msal di\u015fli kutular\u0131<\/a>\u00dcr\u00fcnlerimizi d\u00fcnya \u00e7ap\u0131ndaki m\u00fc\u015fterilerimize ihra\u00e7 ettik ve \u00fcst\u00fcn \u00fcr\u00fcn kalitemiz ve sat\u0131\u015f sonras\u0131 hizmetlerimiz sayesinde iyi bir itibar kazand\u0131k. Yurt i\u00e7i ve yurt d\u0131\u015f\u0131ndaki m\u00fc\u015fterilerimizi i\u015f g\u00f6r\u00fc\u015fmeleri yapmak, bilgi al\u0131\u015fveri\u015finde bulunmak ve <a href=\"https:\/\/www.hydraulic-cylinders.net\/tr\/contact-us\/\">bizimle i\u015fbirli\u011fi yap\u0131n<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>4WRZ\/H(E) Series Pilot Operated Proportional Directional Hydraulic Valve The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic valve is a state-of-the-art component designed to provide exceptional precision, control, and efficiency in hydraulic systems. With its advanced pilot-operated proportional control technology, this valve enables accurate flow regulation and seamless directional changes. The 4WRZ\/H(E) series pilot-operated proportional directional hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2214,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2205","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/product\/2205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/comments?post=2205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/media\/2214"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/media?parent=2205"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/product_brand?post=2205"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/product_cat?post=2205"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/tr\/wp-json\/wp\/v2\/product_tag?post=2205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}