50SD58-30 Solenoid Directional Valve

The 50SD58-30 solenoid directional valve is a versatile and high-performance component used in fluid control systems. Designed to provide precise control over fluid flow, this valve offers reliable operation and enhances the efficiency of various industrial applications.

The 30SD16-22 solenoid directional valve is essential for precise fluid control in industrial applications. Its robust construction, efficient performance, and versatility make it an ideal choice for many fluid control systems. Proper maintenance will ensure its optimal functionality and longevity. Invest in the 30SD16-22 solenoid directional valve to enhance fluid control operations and achieve exceptional results.

50SD58-30 Solenoid Directional Valve Characteristics:

  1. Durable Construction: The 50SD58-30 solenoid directional valve is built with high-quality materials, ensuring durability and resistance to wear, corrosion, and harsh operating conditions. Its robust construction makes it suitable for demanding industrial environments.
  2. Excellent Flow Control: This valve is engineered to deliver accurate and efficient fluid flow control. It offers exceptional repeatability and response times, enabling precise adjustments to meet specific application requirements.
  3. Versatile Configuration: The 50SD58-30 solenoid directional valve is available in various configurations, including inline, manifold, or subplate mounting options. This versatility allows for easy integration into different fluid control systems.
  4. Wide Range of Applications: This valve suits various applications across industries such as manufacturing, automation, process control, and more. It can control hydraulic, pneumatic, or other fluid-based systems.

50SD58-30 Solenoid Directional Valve Parameter:

Rated pressure345 bar(5000 psi)
Peak flowSee performance chart
FluidMineral-based or synthetics with lubricating properties
Fluid temperature range ℃-54 to 107 ℃ (Polyurethane seals)
-40 to 100 ℃ (Buna N seals)
-26 to 204 ℃ (Fluorocarbon seals)
Viscosity range7.4 to 420 mm2/s
Degree of contaminationThe minimum pollution level is ISO4406 level 18/16/13, and level 15/13/11 is recommended to prolong the service life
Internal LeakagePort ③ (De-energized): ≤ 131 mL/min@345 bar
Port ① (Energized): ≤ 279 mL/min@345 bar
CavityVC08-3
Coil Duty RatingContinuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20℃E-coil1.7A at 12VDC; 0.85A at 24VDC
D-coil1.67A at 12VDC; 0.83A at 24VDC
Minimum pull-in voltage85% of nominal at 207 bar

50SD58-30 Solenoid Directional Valve Advantages:

• Continuous-duty rated coil
• Cartridges are voltage interchangeable
• Optional waterproof E-Coils rated up to IP69K
• Efficient wet-armature construction
• Hardened parts for long life

Usage Method Of 50SD58-30 Solenoid Directional Valve:

  • System Assessment: Understand the requirements of your fluid control system, including pressure, flow rate, and directional control needs. Ensure that the 50SD58-30 solenoid directional valve matches the specifications and is suitable for your application.
  • Mounting and Connection: Select the appropriate mounting method based on your system layout and available space. Install the valve securely, ensuring proper alignment with the fluid lines. Connect the valve to the system using compatible fittings and connectors, providing tight and leak-free connections.
  • Electrical Connection: Connect the valve’s solenoid to the appropriate power supply following the manufacturer’s instructions. Ensure correct wiring and adhere to safety guidelines during the electrical connection process.
  • Testing and Adjustment: Gradually introduce fluid flow to the system and monitor the valve’s performance. Test different operating conditions, including pressure and flow variations, and adjust the valve settings to achieve the desired control and system functionality.

How To Replace Delta Shower Valve Cartridge?

Replacing a Delta shower valve cartridge is a common task that can help resolve issues such as leaks, temperature control problems, or water flow inconsistencies. Here’s a step-by-step guide on how to replace a Delta shower valve cartridge:

  1. Gather the necessary tools: Before you begin, make sure you have the following tools ready: adjustable wrench, Phillips screwdriver, needle-nose pliers, Allen wrench set, and a replacement cartridge specific to your Delta shower valve model.
  2. Turn off the water supply: Locate the main water shut-off valve for your home and turn it off to stop the water flow to the shower. If there is no dedicated shut-off valve for the shower, you may need to shut off the main water supply.
  3. Remove the handle: Depending on the Delta shower valve model, the handle removal method may vary. For single-handle valves, locate the set screw on the handle, usually located under a decorative cap or button. Use a Phillips screwdriver to remove the set screw, then pull the handle straight off. For two-handle valves, look for a small set screw on the base of each handle. Remove the set screws and then lift the handles off.
  4. Remove the trim sleeve and escutcheon plate: Next, remove the trim sleeve and escutcheon plate, which are usually located around the valve body. These components may be threaded or held in place with screws. Unscrew or remove any screws and gently pull or twist the sleeve and escutcheon plate to detach them from the wall.
  5. Disconnect the cartridge: Once you gain access to the cartridge, you may need to remove a retaining clip or nut that secures it in place. Use needle-nose pliers or an adjustable wrench to carefully loosen and remove the clip or nut. With the clip or nut removed, you can now pull the cartridge straight out of the valve body. If it’s stuck, you can use a cartridge puller tool for added leverage.
  6. Install the new cartridge: Take the replacement Delta shower valve cartridge and align it with the valve body, ensuring that any tabs or notches match up correctly. Gently push the cartridge into the valve body until it fits snugly.
  7. Reassemble the valve: Once the new cartridge is installed, reassemble the valve by following the steps in reverse order. Secure the cartridge with the retaining clip or nut, then reattach the trim sleeve and escutcheon plate. Make sure all components are tightened securely but avoid over-tightening.
  8. Test for leaks and functionality: Turn the water supply back on and test the shower. Check for any leaks around the valve and ensure that the hot and cold water controls are working correctly. If necessary, make any adjustments to the cartridge or connections to resolve any issues.
  9. Reinstall the handle: Finally, reattach the handle by aligning it with the cartridge stem and securing it with the set screw. Make sure the handle sits flush and operates smoothly.

工厂的能力和产能:

(1) 装配

我们拥有一流的自主研发装配平台。液压油缸生产车间拥有 4 条半自动提升油缸装配线和 1 条全自动倾斜油缸装配线,设计年生产能力 100 万支。特种油缸车间配备了各种规格的半自动清洗装配系统,设计年生产能力 20 万只,并配备了知名数控加工设备、加工中心、高精度油缸加工专用设备、机器人焊接机、自动清洗机、油缸自动装配机、自动喷漆生产线等。现有关键设备 300 多台(套)。设备资源的优化配置和高效利用,保证了产品的精度要求,满足了产品的高质量需求。

(2) 机加工

加工车间配备了定制的斜轨车削中心、加工中心、高速珩磨机、焊接机器人及其他相关设备,可加工最大内径 400 毫米、最大长度 6 米的气缸管。

(3) 焊接

(4) 油漆和涂料

配备中小型圆筒自动水性漆喷涂线,实现机器人自动上下料和自动喷涂,设计产能为每班 4000 件;
我们还拥有一条由动力链驱动的大型油缸半自动喷漆生产线,设计产能为每班 60 箱。

(5) 测试

我们拥有一流的检验设施和试验台,确保气缸的性能符合要求。

 

 

We are one of the best hydraulic cylinder manufacturers. We can offer comprehensive hydraulic cylinders. We also provide corresponding 农用齿轮箱. We have exported our products to clients worldwide and earned a good reputation because of our superior product quality and after-sales service. We welcome customers at home and abroad to contact us to negotiate business, exchange information, and 与我们合作!

 