{"id":2175,"date":"2023-10-31T03:47:18","date_gmt":"2023-10-31T03:47:18","guid":{"rendered":"https:\/\/hydraulic-cylinders.net\/?post_type=product&#038;p=2175"},"modified":"2023-10-31T03:48:39","modified_gmt":"2023-10-31T03:48:39","slug":"dbetx-series-proportional-pressure-relief-hydraulic-valve","status":"publish","type":"product","link":"https:\/\/www.hydraulic-cylinders.net\/zh\/%e4%ba%a7%e5%93%81\/dbetx-series-proportional-pressure-relief-hydraulic-valve\/","title":{"rendered":"DBETX Series Proportional Pressure Relief Hydraulic Valve"},"content":{"rendered":"<h1 style=\"text-align: center;\"><strong>DBETX Series Proportional Pressure Relief Hydraulic Valve <\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2186\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/10\/dbetx-series-proportional-pressure-relief-hydraulic-valve-1-300x300.webp\" alt=\"\" width=\"400\" height=\"400\" \/><\/p>\n<p>The DBETX series proportional pressure relief hydraulic valve is a versatile and high-performance hydraulic component designed to provide precise pressure relief in hydraulic systems. Engineered with advanced proportional control technology, this valve ensures optimal performance, efficiency, and safety.<\/p>\n<p>The DBETX series proportional pressure relief hydraulic valve empowers hydraulic systems with precise pressure control, enhanced efficiency, and equipment protection. With its proportional pressure relief capabilities, this valve ensures optimal performance across a wide range of applications. By following the recommended usage methods and maintenance guidelines, you can maximize the benefits and reliability of the DBETX series valve, elevating the performance and control of your hydraulic system. Upgrade your hydraulic setup today and experience superior pressure regulation with the DBETX series proportional pressure relief hydraulic valve.<\/p>\n<p>DBETX Series Proportional Pressure Relief Hydraulic Valve Key Characteristics:<\/p>\n<ul>\n<li>\u6bd4\u4f8b\u538b\u529b\u91ca\u653e\uff1a\n<ul>\n<li>The DBETX series valve delivers proportional pressure relief, allowing for accurate and dynamic hydraulic pressure control.<\/li>\n<li>It ensures precise pressure regulation in response to varying load conditions, preventing damage to hydraulic components and optimizing system performance.<\/li>\n<\/ul>\n<\/li>\n<li>\u63d0\u9ad8\u7cfb\u7edf\u6548\u7387\uff1a\n<ul>\n<li>This valve enables precise control of hydraulic flow rates, resulting in enhanced system efficiency and reduced energy consumption.<\/li>\n<li>Maintaining the desired pressure levels minimizes pressure fluctuations, enhances overall productivity, and reduces operational costs.<\/li>\n<\/ul>\n<\/li>\n<li>\u5b89\u5168\u548c\u8bbe\u5907\u4fdd\u62a4\uff1a\n<ul>\n<li>The DBETX series valve acts as a safeguard by limiting the pressure within the hydraulic system, protecting equipment and operators from potential damage or accidents.<\/li>\n<li>It prevents overloading and ensures the longevity of hydraulic components, reducing the risk of system failures and downtime.<\/li>\n<\/ul>\n<\/li>\n<li>\u5e94\u7528\u8303\u56f4\u5e7f\u6cdb\uff1a\n<ul>\n<li>With its versatile design and compatibility with various hydraulic systems, the DBETX series valve can be used in a wide range of applications across industries such as manufacturing, construction, agriculture, and more.<\/li>\n<li>It offers flexibility and adaptability, making it suitable for diverse hydraulic setups and requirements.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>DBETX Series Proportional Pressure Relief Hydraulic Valve Parameter:<\/strong><\/h2>\n<table class=\"table table-bordered table-hover table-colored\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"7\" align=\"left\" valign=\"middle\"><strong>\u4e00\u822c\u7684<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u5efa\u9020<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Poppet valve, direct drive<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u9a71\u52a8<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u65e0\u4f4d\u7f6e\u63a7\u5236\u7684\u6bd4\u4f8b\u7535\u78c1\u9600\uff0c\u5e26\u5916\u90e8\u653e\u5927\u5668<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u8fde\u63a5\u7c7b\u578b<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Subplate, mounting hole configuration NG6 (ISO 4401-03-02-0-94)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u5b89\u88c5\u4f4d\u7f6e<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u9009\u4fee\u7684<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u73af\u5883\u6e29\u5ea6\u8303\u56f4<\/td>\n<td align=\"left\" valign=\"middle\">\u00a0\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20&#8230;+50<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u91cd\u91cf<\/td>\n<td align=\"left\" valign=\"middle\">\u516c\u65a4<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">about 2.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u6297\u632f\u6027\uff0c\u6d4b\u8bd5\u6761\u4ef6<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Max. 25 g, shaken in 3 dimensions(24 h)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" align=\"left\" valign=\"middle\"><strong>Hydraulic \u00a0\u00a0\u00a0 (measured with HLP 46, Voil=40\u2103\u00b15\u2103)<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u538b\u529b\u6d41\u4f53<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u6db2\u538b\u6cb9\u7b26\u5408 DIN 51524\u2026535 \u6807\u51c6\uff0c\u5176\u4ed6\u6db2\u4f53\u9700\u4e8b\u5148\u54a8\u8be2\u3002<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" align=\"left\" valign=\"middle\">\u7c98\u5ea6\u8303\u56f4<\/td>\n<td align=\"left\" valign=\"middle\">\u53d7\u5230\u63a8\u5d07\u7684<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a020&#8230;100<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u6700\u5927\u5141\u8bb8\u503c<\/td>\n<td colspan=\"4\" align=\"left\" valign=\"middle\">\u00a010&#8230;800<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u538b\u529b\u6d41\u4f53\u6e29\u5ea6\u8303\u56f4<\/td>\n<td align=\"left\" valign=\"middle\">\u2103<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">-20&#8230;+80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">Maximum permitted degree of contamination of pressure fluid Purity class to ISO 4406(c)<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">18\/16\/13\u73ed<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u6d41\u5411<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u53c2\u89c1\u7b26\u53f7<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. setting pressure \u00a0(Q = 1 l\/min)<\/td>\n<td align=\"left\" valign=\"middle\">\u9152\u5427<\/td>\n<td align=\"left\" valign=\"middle\">50<\/td>\n<td align=\"left\" valign=\"middle\">80<\/td>\n<td align=\"left\" valign=\"middle\">180<\/td>\n<td align=\"left\" valign=\"middle\">250<\/td>\n<td align=\"left\" valign=\"middle\">315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Min. settable pressure (Q = 1 l\/min)<\/td>\n<td align=\"left\" valign=\"middle\">\u9152\u5427<\/td>\n<td align=\"left\" valign=\"middle\">2<\/td>\n<td align=\"left\" valign=\"middle\">3<\/td>\n<td align=\"left\" valign=\"middle\">4<\/td>\n<td align=\"left\" valign=\"middle\">5<\/td>\n<td align=\"left\" valign=\"middle\">8<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. operating \u00a0pressure(Q = 1 l\/min)<\/td>\n<td align=\"left\" valign=\"middle\">\u9152\u5427<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Port \u00a0P: 315<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. pressure<\/td>\n<td align=\"left\" valign=\"middle\">\u9152\u5427<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Port \u00a0T: 250<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Max. mechanical pressure limitation level, e.g. when solenoid current I&gt;Imax<\/td>\n<td align=\"left\" valign=\"middle\">\u9152\u5427<\/td>\n<td align=\"left\" valign=\"middle\">\uff1c55<\/td>\n<td align=\"left\" valign=\"middle\">\uff1c85<\/td>\n<td align=\"left\" valign=\"middle\">\uff1c186<\/td>\n<td align=\"left\" valign=\"middle\">\uff1c258<\/td>\n<td align=\"left\" valign=\"middle\">\uff1c325<\/td>\n<\/tr>\n<tr class=\"firstRow\">\n<td colspan=\"7\" align=\"left\" valign=\"middle\"><strong>\u9759\u6001\/\u52a8\u6001<\/strong><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u6ede\u540e<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u22644<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">Response time 100% signal changen<\/td>\n<td align=\"left\" valign=\"middle\">\u591a\u53d1\u6027\u786c\u5316\u75c7<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">On\uff1c60 \/ Off\uff1c70<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u53cd\u8f6c\u8303\u56f4<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u22643<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" align=\"left\" valign=\"middle\"><strong>\u7535\u6c14\u6570\u636e<\/strong><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"middle\">\u5faa\u73af\u6301\u7eed\u65f6\u95f4\u56e0\u5b50<\/td>\n<td align=\"left\" valign=\"middle\">%<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">100 ED<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u4fdd\u62a4\u7a0b\u5ea6<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">\u7b26\u5408 DIN 40050 \u548c IEC 14434\/5 \u6807\u51c6\u7684 IP 65 \u9632\u62a4\u7b49\u7ea7<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u7535\u78c1\u9600\u8fde\u63a5<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">Plug-in connector to DIN EN 175301-803\/ISO 4400<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\" valign=\"middle\">\u529b\u91cf<\/td>\n<td colspan=\"5\" align=\"left\" valign=\"middle\">24VDCnom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>DBETX Series Proportional Pressure Relief Hydraulic Valve Advantages:<\/strong><\/h2>\n<p>\u2022 \u76f4\u63a5\u9650\u5236\u7cfb\u7edf\u538b\u529b<br \/>\n\u2022 Can adjust pressure by controlling the current with the solenoid according to the characteristic curve<br \/>\n\u2022 In the event of electrical failure, the restricted pressure is still within safety level (solenoid current &gt; Imax)<br \/>\n\u2022 External amplifying sub-plate mounting has slope and valve calibration functions (separate order)<\/p>\n<h2><strong>Usage Method Of DBETX Series Proportional Pressure Relief Hydraulic Valve<\/strong><strong>:<\/strong><\/h2>\n<ul>\n<li>\u7cfb\u7edf\u8bc4\u4f30\uff1a\n<ul>\n<li>Evaluate your hydraulic system and identify the specific requirements for pressure control and relief.<\/li>\n<li>Determine if the DBETX series valve is compatible with your system and suitable for your application based on its pressure range, flow capacity, and other specifications.<\/li>\n<\/ul>\n<\/li>\n<li>\u9600\u95e8\u9009\u62e9\uff1a\n<ul>\n<li>Choose the appropriate DBETX series valve variant based on your system parameters, pressure range, and flow requirements.<\/li>\n<li>\u8003\u8651\u6700\u5927\u538b\u529b\u7b49\u7ea7\u3001\u54cd\u5e94\u65f6\u95f4\u548c\u8fd0\u884c\u6761\u4ef6\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u5b89\u88c5\uff1a\n<ul>\n<li>\u8bf7\u4ed4\u7ec6\u9075\u5faa\u5236\u9020\u5546\u7684\u5b89\u88c5\u8bf4\u660e\uff0c\u786e\u4fdd\u6b63\u786e\u5bf9\u9f50\u5e76\u7262\u56fa\u5b89\u88c5\u9600\u95e8\u3002<\/li>\n<li>\u5c06\u9600\u95e8\u8fde\u63a5\u5230\u6db2\u538b\u7cfb\u7edf\uff0c\u786e\u4fdd\u8fde\u63a5\u65e0\u6cc4\u6f0f\u4e14\u6d41\u5411\u6b63\u786e\u5bf9\u9f50\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u538b\u529b\u8c03\u8282\uff1a\n<ul>\n<li>Adjust the pressure relief setting on the DBETX series valve to match the desired pressure range for your application.<\/li>\n<li>Utilize the proportional control signals or adjustment mechanisms provided with the valve to achieve precise pressure regulation.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><strong>How To Adjust A Hydraulic Pressure Relief Valve?<\/strong><\/h2>\n<p>\u8c03\u8282\u6db2\u538b\u6cc4\u538b\u9600\u53ef\u4ee5\u8bbe\u5b9a\u6db2\u538b\u7cfb\u7edf\u4e2d\u6240\u9700\u7684\u6700\u5927\u538b\u529b\u3002\u8fd9\u5bf9\u4e8e\u7ef4\u62a4\u7cfb\u7edf\u5b8c\u6574\u6027\u548c\u9632\u6b62\u90e8\u4ef6\u635f\u574f\u81f3\u5173\u91cd\u8981\u3002\u4ee5\u4e0b\u662f\u8c03\u8282\u6db2\u538b\u6cc4\u538b\u9600\u7684\u8be6\u7ec6\u6b65\u9aa4\uff1a<\/p>\n<ol>\n<li><strong>\u8bc6\u522b\u6cc4\u538b\u9600\uff1a<\/strong>\n<ul>\n<li>\u627e\u5230\u6db2\u538b\u7cfb\u7edf\u4e2d\u7684\u6cc4\u538b\u9600\u3002\u5b83\u901a\u5e38\u5b89\u88c5\u5728\u6db2\u538b\u7ba1\u8def\u4e2d\uff0c\u800c\u4e14\u5f80\u5f80\u9760\u8fd1\u6cf5\u6216\u63a7\u5236\u9600\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u4e86\u89e3\u9600\u95e8\u8bbe\u8ba1\uff1a<\/strong>\n<ul>\n<li>\u719f\u6089\u4f60\u6240\u4f7f\u7528\u538b\u529b\u91ca\u653e\u9600\u7684\u5177\u4f53\u8bbe\u8ba1\u3002\u4e0d\u540c\u7684\u9600\u95e8\u53ef\u80fd\u5177\u6709\u4e0d\u540c\u7684\u8c03\u8282\u673a\u6784\uff0c\u4f8b\u5982\u65cb\u94ae\u3001\u87ba\u9489\u6216\u9501\u7d27\u87ba\u6bcd\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u786e\u5b9a\u6240\u9700\u538b\u529b\uff1a<\/strong>\n<ul>\n<li>\u8bc4\u4f30\u6db2\u538b\u7cfb\u7edf\u7684\u9700\u6c42\u5e76\u786e\u5b9a\u6240\u9700\u7684\u6700\u5927\u538b\u529b\u3002\u8fd9\u5c06\u6307\u5bfc\u60a8\u51c6\u786e\u8c03\u8282\u6cc4\u538b\u9600\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u51c6\u5907\u7cfb\u7edf\uff1a<\/strong>\n<ul>\n<li>\u5728\u8fdb\u884c\u4efb\u4f55\u8c03\u6574\u4e4b\u524d\uff0c\u8bf7\u5173\u95ed\u6db2\u538b\u7cfb\u7edf\uff0c\u5e76\u901a\u8fc7\u6765\u56de\u79fb\u52a8\u63a7\u5236\u6746\u6216\u6309\u7167\u5236\u9020\u5546\u63a8\u8350\u7684\u6b65\u9aa4\u91ca\u653e\u538b\u529b\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u627e\u5230\u8c03\u8282\u673a\u6784\uff1a<\/strong>\n<ul>\n<li>\u786e\u5b9a\u6cc4\u538b\u9600\u4e0a\u7684\u8c03\u8282\u673a\u6784\u3002\u5b83\u53ef\u80fd\u662f\u4f4d\u4e8e\u9600\u4f53\u4e0a\u6216\u5176\u9644\u8fd1\u7684\u65cb\u94ae\u3001\u87ba\u9489\u6216\u9501\u7d27\u87ba\u6bcd\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u8c03\u6574\u9600\u95e8\uff1a<\/strong>\n<ul>\n<li>\u5982\u679c\u9600\u95e8\u5e26\u6709\u65cb\u94ae\u6216\u624b\u67c4\uff0c\u987a\u65f6\u9488\u65cb\u8f6c\u53ef\u589e\u5927\u6cc4\u538b\u503c\uff0c\u9006\u65f6\u9488\u65cb\u8f6c\u53ef\u51cf\u5c0f\u6cc4\u538b\u503c\u3002\u5982\u679c\u9600\u95e8\u5e26\u6709\u87ba\u4e1d\uff0c\u987a\u65f6\u9488\u65cb\u8f6c\u53ef\u589e\u5927\u6cc4\u538b\u503c\uff0c\u9006\u65f6\u9488\u65cb\u8f6c\u53ef\u51cf\u5c0f\u6cc4\u538b\u503c\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u9010\u6b65\u8c03\u6574\uff1a<\/strong>\n<ul>\n<li>\u8c03\u8282\u6cc4\u538b\u9600\u65f6\uff0c\u5e94\u8fdb\u884c\u5c0f\u5e45\u6e10\u8fdb\u5f0f\u8c03\u6574\uff0c\u907f\u514d\u538b\u529b\u7a81\u7136\u6216\u5267\u70c8\u53d8\u5316\u3002\u8fd9\u6837\u53ef\u4ee5\u5fae\u8c03\u6700\u5927\u538b\u529b\uff0c\u4ece\u800c\u8fbe\u5230\u6240\u9700\u7684\u6027\u80fd\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u89c2\u5bdf\u7cfb\u7edf\uff1a<\/strong>\n<ul>\n<li>\u6bcf\u6b21\u8c03\u6574\u540e\uff0c\u90fd\u8981\u89c2\u5bdf\u6db2\u538b\u7cfb\u7edf\u53ca\u5176\u90e8\u4ef6\u3002\u6ce8\u610f\u538b\u529b\u8868\u8bfb\u6570\uff0c\u67e5\u770b\u662f\u5426\u4e0e\u6240\u9700\u7684\u6700\u5927\u538b\u529b\u76f8\u7b26\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u9a8c\u8bc1\uff1a<\/strong>\n<ul>\n<li>\u64cd\u4f5c\u6db2\u538b\u7cfb\u7edf\u5e76\u76d1\u6d4b\u538b\u529b\uff0c\u786e\u4fdd\u5176\u4fdd\u6301\u5728\u6240\u9700\u8303\u56f4\u5185\u3002\u68c0\u67e5\u662f\u5426\u5b58\u5728\u4efb\u4f55\u538b\u529b\u6ce2\u52a8\u6216\u5f02\u5e38\u60c5\u51b5\uff0c\u8fd9\u4e9b\u60c5\u51b5\u53ef\u80fd\u8868\u660e\u9700\u8981\u8fdb\u4e00\u6b65\u8c03\u6574\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u9501\u5b9a\u8c03\u6574\uff1a<\/strong>\n<ul>\n<li>\u8fbe\u5230\u6240\u9700\u7684\u6cc4\u538b\u8bbe\u5b9a\u503c\u540e\uff0c\u52a1\u5fc5\u56fa\u5b9a\u8c03\u8282\u673a\u6784\uff0c\u4ee5\u9632\u6b62\u610f\u5916\u66f4\u6539\u3002\u6709\u4e9b\u9600\u95e8\u53ef\u80fd\u5e26\u6709\u9501\u7d27\u87ba\u6bcd\u6216\u7d27\u56fa\u87ba\u9489\uff0c\u62e7\u7d27\u540e\u5373\u53ef\u5c06\u8c03\u8282\u503c\u56fa\u5b9a\u5230\u4f4d\u3002<\/li>\n<\/ul>\n<\/li>\n<li><strong>\u76d1\u6d4b\u548c\u56de\u987e\uff1a<\/strong>\n<ul>\n<li>\u5b9a\u671f\u68c0\u67e5\u6cc4\u538b\u9600\u548c\u6db2\u538b\u7cfb\u7edf\u3002\u5982\u679c\u7cfb\u7edf\u53d1\u751f\u53d8\u5316\u6216\u9700\u8981\u8c03\u6574\u6240\u9700\u6700\u5927\u538b\u529b\uff0c\u8bf7\u91cd\u65b0\u68c0\u67e5\u6cc4\u538b\u9600\u5e76\u6839\u636e\u9700\u8981\u91cd\u590d\u8c03\u200b\u200b\u6574\u8fc7\u7a0b\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h2><strong>\u5de5\u5382\u7684\u80fd\u529b\u548c\u4ea7\u80fd\uff1a<\/strong><\/h2>\n<h3>(1) \u88c5\u914d<\/h3>\n<p>\u6211\u4eec\u62e5\u6709\u4e00\u6d41\u7684\u81ea\u4e3b\u7814\u53d1\u88c5\u914d\u5e73\u53f0\u3002\u6db2\u538b\u6cb9\u7f38\u751f\u4ea7\u8f66\u95f4\u62e5\u6709 4 \u6761\u534a\u81ea\u52a8\u63d0\u5347\u6cb9\u7f38\u88c5\u914d\u7ebf\u548c 1 \u6761\u5168\u81ea\u52a8\u503e\u659c\u6cb9\u7f38\u88c5\u914d\u7ebf\uff0c\u8bbe\u8ba1\u5e74\u751f\u4ea7\u80fd\u529b 100 \u4e07\u652f\u3002\u7279\u79cd\u6cb9\u7f38\u8f66\u95f4\u914d\u5907\u4e86\u5404\u79cd\u89c4\u683c\u7684\u534a\u81ea\u52a8\u6e05\u6d17\u88c5\u914d\u7cfb\u7edf\uff0c\u8bbe\u8ba1\u5e74\u751f\u4ea7\u80fd\u529b 20 \u4e07\u53ea\uff0c\u5e76\u914d\u5907\u4e86\u77e5\u540d\u6570\u63a7\u52a0\u5de5\u8bbe\u5907\u3001\u52a0\u5de5\u4e2d\u5fc3\u3001\u9ad8\u7cbe\u5ea6\u6cb9\u7f38\u52a0\u5de5\u4e13\u7528\u8bbe\u5907\u3001\u673a\u5668\u4eba\u710a\u63a5\u673a\u3001\u81ea\u52a8\u6e05\u6d17\u673a\u3001\u6cb9\u7f38\u81ea\u52a8\u88c5\u914d\u673a\u3001\u81ea\u52a8\u55b7\u6f06\u751f\u4ea7\u7ebf\u7b49\u3002\u73b0\u6709\u5173\u952e\u8bbe\u5907 300 \u591a\u53f0\uff08\u5957\uff09\u3002\u8bbe\u5907\u8d44\u6e90\u7684\u4f18\u5316\u914d\u7f6e\u548c\u9ad8\u6548\u5229\u7528\uff0c\u4fdd\u8bc1\u4e86\u4ea7\u54c1\u7684\u7cbe\u5ea6\u8981\u6c42\uff0c\u6ee1\u8db3\u4e86\u4ea7\u54c1\u7684\u9ad8\u8d28\u91cf\u9700\u6c42\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-626\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp\" alt=\"\" width=\"495\" height=\"260\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-300x158.webp 495w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-1-480x252.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 495px, 100vw\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-627\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-2-300x189.webp\" alt=\"\" width=\"413\" height=\"260\" \/><\/p>\n<h3>(2) \u673a\u52a0\u5de5<\/h3>\n<p>\u52a0\u5de5\u8f66\u95f4\u914d\u5907\u4e86\u5b9a\u5236\u7684\u659c\u8f68\u8f66\u524a\u4e2d\u5fc3\u3001\u52a0\u5de5\u4e2d\u5fc3\u3001\u9ad8\u901f\u73e9\u78e8\u673a\u3001\u710a\u63a5\u673a\u5668\u4eba\u53ca\u5176\u4ed6\u76f8\u5173\u8bbe\u5907\uff0c\u53ef\u52a0\u5de5\u6700\u5927\u5185\u5f84 400 \u6beb\u7c73\u3001\u6700\u5927\u957f\u5ea6 6 \u7c73\u7684\u6c14\u7f38\u7ba1\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-628 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-1024x391.webp\" alt=\"\" width=\"1024\" height=\"391\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-980x374.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-3-480x183.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(3) \u710a\u63a5<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-629 size-large\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-1024x510.webp\" alt=\"\" width=\"1024\" height=\"510\" srcset=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-980x488.webp 980w, https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-4-480x239.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/p>\n<h3>(4) \u6cb9\u6f06\u548c\u6d82\u6599<\/h3>\n<p>\u914d\u5907\u4e2d\u5c0f\u578b\u5706\u7b52\u81ea\u52a8\u6c34\u6027\u6f06\u55b7\u6d82\u7ebf\uff0c\u5b9e\u73b0\u673a\u5668\u4eba\u81ea\u52a8\u4e0a\u4e0b\u6599\u548c\u81ea\u52a8\u55b7\u6d82\uff0c\u8bbe\u8ba1\u4ea7\u80fd\u4e3a\u6bcf\u73ed 4000 \u4ef6\uff1b<br \/>\n\u6211\u4eec\u8fd8\u62e5\u6709\u4e00\u6761\u7531\u52a8\u529b\u94fe\u9a71\u52a8\u7684\u5927\u578b\u6cb9\u7f38\u534a\u81ea\u52a8\u55b7\u6f06\u751f\u4ea7\u7ebf\uff0c\u8bbe\u8ba1\u4ea7\u80fd\u4e3a\u6bcf\u73ed 60 \u7bb1\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-630\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-5-300x213.webp\" alt=\"\" width=\"366\" height=\"260\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-631\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-6-300x225.webp\" alt=\"\" width=\"347\" height=\"260\" \/><\/p>\n<h3>(5) \u6d4b\u8bd5<\/h3>\n<p>\u6211\u4eec\u62e5\u6709\u4e00\u6d41\u7684\u68c0\u9a8c\u8bbe\u65bd\u548c\u8bd5\u9a8c\u53f0\uff0c\u786e\u4fdd\u6c14\u7f38\u7684\u6027\u80fd\u7b26\u5408\u8981\u6c42\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-632\" src=\"https:\/\/hydraulic-cylinders.net\/wp-content\/uploads\/2023\/08\/hydraulic-cylinder-product-8-300x200.webp\" alt=\"\" width=\"389\" height=\"260\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u6211\u4eec\u662f\u6700\u597d\u7684\u6db2\u538b\u7f38\u5236\u9020\u5546\u4e4b\u4e00\u3002\u6211\u4eec\u80fd\u591f\u63d0\u4f9b\u5168\u9762\u7684\u6db2\u538b\u7f38\u3002\u6211\u4eec\u8fd8\u63d0\u4f9b\u76f8\u5e94\u7684 <a href=\"https:\/\/hzpt.com\/agricultural-pto-gearbox\/\" target=\"_blank\" rel=\"noopener\">\u519c\u7528\u9f7f\u8f6e\u7bb1<\/a>\u51ed\u501f\u5353\u8d8a\u7684\u4ea7\u54c1\u8d28\u91cf\u548c\u552e\u540e\u670d\u52a1\uff0c\u6211\u4eec\u7684\u4ea7\u54c1\u8fdc\u9500\u4e16\u754c\u5404\u5730\uff0c\u8d62\u5f97\u4e86\u826f\u597d\u7684\u58f0\u8a89\u3002\u6211\u4eec\u6b22\u8fce\u56fd\u5185\u5916\u5ba2\u6237\u4e0e\u6211\u4eec\u8054\u7cfb\u6d3d\u8c08\u4e1a\u52a1\u3001\u4ea4\u6d41\u4fe1\u606f\uff0c\u5e76 <a href=\"https:\/\/www.hydraulic-cylinders.net\/zh\/contact-us\/\">\u4e0e\u6211\u4eec\u5408\u4f5c<\/a>!<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>DBETX Series Proportional Pressure Relief Hydraulic Valve The DBETX series proportional pressure relief hydraulic valve is a versatile and high-performance hydraulic component designed to provide precise pressure relief in hydraulic systems. Engineered with advanced proportional control technology, this valve ensures optimal performance, efficiency, and safety. The DBETX series proportional pressure relief hydraulic valve empowers hydraulic [&hellip;]<\/p>","protected":false},"featured_media":2187,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[1376],"product_tag":[1433],"class_list":{"0":"post-2175","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hydraulic-cylinder","7":"product_tag-hydraulic-valve","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/product\/2175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/comments?post=2175"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/media\/2187"}],"wp:attachment":[{"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/media?parent=2175"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/product_brand?post=2175"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/product_cat?post=2175"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hydraulic-cylinders.net\/zh\/wp-json\/wp\/v2\/product_tag?post=2175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}